• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BQ08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BQ08-0AX0 WinCC flexible 2008

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6381-2BQ08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BQ08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software includes features such as faceplates, scripts, trend displays, alarm management, recipe management, and multi-language project support. It integrates with STEP 7 for seamless PLC-HMI project engineering and supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces. The 2008 edition introduced enhanced usability features, improved simulation capabilities, and extended device support compared to earlier versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering environments. It is suitable for industries such as automotive, food and beverage, pharmaceuticals, and general factory automation where operator visualization and control are required. The software's scalability makes it applicable to both small standalone machine panels and large distributed HMI installations.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single-user license
    Compatible HMI Devices SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based systems
    PLC Integration SIMATIC STEP 7 (integrated engineering)
    Communication Protocols PROFIBUS, PROFINET, MPI, Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Project Languages Up to 32 languages per project
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    Simulation Integrated HMI runtime simulator
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000001
    License not found or invalid license key detected during software startup
    Verify that the correct license (Automation License Manager) is installed and activated on the engineering PC. Re-transfer the license if necessary.
    Event ID: 1000002
    Communication error between WinCC flexible and the connected HMI device during download
    Check the physical connection (USB, Ethernet, or MPI/PROFIBUS cable). Verify the correct communication interface is selected in the project transfer settings.
    Event ID: 1000003
    Project compilation error due to inconsistent configuration or missing tag references
    Open the project and resolve all reported inconsistencies in the compiler output window. Check for missing PLC tags or broken connections.
    Event ID: 1000004
    Runtime simulation failure — simulator cannot start
    Ensure the PC meets minimum system requirements. Check that no other WinCC flexible runtime instance is already running. Reinstall the simulation component if the issue persists.
    Event ID: 1000005
    Transfer to HMI device failed — device not reachable
    Confirm the HMI device is powered on and in transfer mode. Verify IP address or MPI address settings match between the project and the physical device.
    Event ID: 1000006
    Incompatible project version — project was created with a newer or older version of WinCC flexible
    Open the project with the correct version of WinCC flexible or use the migration wizard to convert the project to the installed software version.
    Event ID: 1000007
    Automation License Manager reports license in use on another machine
    Release the license from the other machine using the Automation License Manager, or use a transferable license medium (USB dongle) to move the license to the current PC.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI devices including Micro Panels (TP 170 Micro, OP 73 Micro), Mobile Panels, Operator Panels (OP 77, TP 177, OP 177), Multi Panels (MP 277, MP 377), and PC-based runtime systems.

    Is WinCC flexible 2008 compatible with TIA Portal projects?

    WinCC flexible 2008 is not natively compatible with TIA Portal (WinCC in TIA Portal). However, Siemens provides a migration tool to convert WinCC flexible projects into TIA Portal format.

    What operating systems are supported for installing WinCC flexible 2008?

    WinCC flexible 2008 supports Windows XP (SP2 or higher), Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 8, Windows 10, or 64-bit operating systems without compatibility workarounds.

    Does WinCC flexible 2008 require a hardware dongle or software license?

    The license is managed via the Siemens Automation License Manager (ALM) software. It can be stored on the PC hard drive or on a transferable USB license key, depending on the license variant purchased.

    Can WinCC flexible 2008 communicate with non-Siemens PLCs?

    Yes, WinCC flexible 2008 supports communication with third-party controllers via OPC DA (OLE for Process Control) in addition to native Siemens PROFIBUS, PROFINET, and MPI connections.

    Troubleshooting

    Software fails to start and reports a missing or invalid license

    Open the Siemens Automation License Manager and check whether a valid WinCC flexible 2008 license is present and not expired or corrupted.

    Transfer a valid license to the engineering PC using the Automation License Manager. If the license is on a USB dongle, ensure the dongle is connected before launching the software.

    Project download to HMI panel fails with a connection error

    Check the transfer settings in WinCC flexible (Transfer > PC/PG Settings) and verify the selected interface (USB, Ethernet, or MPI) matches the physical connection. Ping the HMI device IP address if using Ethernet.

    Correct the interface settings, ensure the HMI is in transfer mode (press Transfer on the start center), and verify that no firewall is blocking the connection on the engineering PC.

    Compilation errors appear when building the HMI project

    Review the compiler output window for specific error messages. Common causes include unresolved PLC tag references, missing screen objects, or unsupported functions for the target device type.

    Resolve each reported error by correcting tag connections, removing unsupported objects, or updating the target device type in the project settings to match the actual hardware.

    WinCC flexible 2008 crashes or freezes on Windows 7

    Check Windows Event Viewer for application crash logs. Verify that all required Windows updates and Siemens software patches (service packs for WinCC flexible 2008) are installed.

    Install the latest WinCC flexible 2008 service pack available from Siemens Industry Online Support. Ensure the PC meets minimum RAM and CPU requirements and that no conflicting software is installed.

    Simulation does not reflect the latest project changes

    The simulation may be running a previously compiled version of the project. Check whether the project was saved and recompiled after the last changes were made.

    Save the project, perform a full compilation (Project > Compile > All), and restart the simulation. Ensure no compilation errors are present before launching the simulator.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart