Siemens 6AV6381-2BQ08-0AH0 WinCC flexible 2008
€ 3.495,00
The Siemens 6AV6381-2BQ08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications across Siemens' SIMATIC HMI panel portfolio. It is designed for use on standard PC hardware running compatible Windows operating systems.
WinCC flexible 2008 offers a scalable engineering framework supporting configuration of the full range of SIMATIC HMI devices, from Micro Panels and Mobile Panels to Multi Panels and PC-based runtime systems. The software includes tag management, alarm logging, trend displays, recipe management, and multi-language project support. It integrates with SIMATIC STEP 7 via the SIMATIC Manager and supports communication drivers for S7-200, S7-300, S7-400, and third-party PLCs via OPC and other standard interfaces. The 2008 version introduced enhanced usability features and expanded device support compared to earlier releases.
WinCC flexible 2008 is widely used in manufacturing automation, process industries, packaging machinery, and material handling systems where SIMATIC HMI panels are deployed. It is suitable for machine builders and system integrators who need a consistent engineering tool across multiple HMI hardware platforms. The software's scalability makes it applicable to both small standalone machine HMIs and larger distributed visualization systems.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| License Type | Single-user license |
| Compatible HMI Devices | SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC Runtime |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, and third-party via OPC |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Communication Interfaces | MPI, PROFIBUS, PROFINET, Ethernet, OPC |
| Language Support | Multi-language project configuration |
| Integration | SIMATIC STEP 7 via SIMATIC Manager |
| Series/Product Family | SIMATIC WinCC flexible |
Common Error Codes & System Events
- Event ID: 1000000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
Check that the correct Runtime version is installed on the HMI device and that the project was compiled without errors before downloading. - Event ID: 1000003
- Communication connection to PLC lost — the HMI cannot establish or maintain a connection to the configured PLC.
Verify network cabling, IP address settings, and PLC communication parameters. Check that the PLC is in RUN mode and the correct communication driver is configured. - Event ID: 1000010
- Tag read/write error — a configured tag could not be read from or written to the PLC.
Confirm the tag address exists in the PLC program and that data types match between the HMI project and PLC. Check for PLC program changes that may have shifted addresses. - Event ID: 1000020
- Recipe data error — a recipe record could not be read or written correctly.
Verify recipe configuration in the WinCC flexible project, check available storage space on the HMI device, and ensure recipe tag addresses are valid in the PLC. - Event ID: 1000030
- Project download error — the project could not be transferred to the HMI device.
Check the transfer connection (USB, Ethernet, or MPI/PROFIBUS), ensure the HMI device is in Transfer mode, and verify that the project compiles without errors in WinCC flexible. - Event ID: 1000040
- License error — no valid license found for WinCC flexible Runtime or Engineering software.
Verify that the software license (Automation License Manager) is correctly installed and activated. Check that the license matches the installed software version and edition. - Event ID: 1000050
- Alarm logging overflow — the alarm buffer on the HMI device is full and older alarms are being overwritten.
Increase the alarm buffer size in the project settings, archive alarms to an external storage medium, or acknowledge and clear pending alarms regularly.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI devices including Micro Panels (KTP series), Mobile Panels, Operator Panels (OP series), Multi Panels (MP series), and PC-based Runtime systems. The specific device list depends on the installed software edition (Micro, Compact, Standard, or Advanced).
Is WinCC flexible 2008 compatible with SIMATIC STEP 7?
Yes, WinCC flexible 2008 integrates with SIMATIC STEP 7 through the SIMATIC Manager, allowing shared symbol tables and simplified tag import from S7 projects. This integration reduces configuration effort when both tools are installed on the same engineering PC.
What operating systems are supported for installing WinCC flexible 2008?
WinCC flexible 2008 is compatible with Windows XP Professional, Windows Vista, and Windows 7 (32-bit editions). It is not natively supported on 64-bit operating systems without compatibility measures.
Can WinCC flexible 2008 communicate with third-party PLCs?
Yes, WinCC flexible 2008 supports communication with third-party PLCs via OPC DA (Data Access) and a range of additional communication drivers. This allows integration with non-Siemens controllers in mixed-vendor environments.
What is the difference between WinCC flexible Engineering and WinCC flexible Runtime?
WinCC flexible Engineering is the PC-based configuration tool used to create and edit HMI projects, while WinCC flexible Runtime is the software that executes the project on a PC-based HMI. Panel-based SIMATIC HMI devices have their own embedded Runtime and do not require a separate Runtime license.
Troubleshooting
Project cannot be downloaded to the HMI panel
Check the transfer connection type (USB, Ethernet, MPI) and verify the HMI device is set to Transfer mode. Confirm the PC firewall is not blocking the connection and that the correct communication interface is selected in WinCC flexible.
Set the HMI panel to Transfer mode via the Start Center or Control Panel. Disable PC firewall temporarily for testing, select the correct transfer channel in WinCC flexible under Transfer settings, and retry the download.
HMI panel shows 'No connection to PLC' at Runtime
Verify the PLC IP address or MPI/PROFIBUS address configured in the WinCC flexible project matches the actual PLC settings. Check physical cabling and network switch status.
Correct the PLC address in the WinCC flexible connection settings, recompile and download the project. Inspect Ethernet or PROFIBUS cables and connectors for damage, and confirm the PLC is powered and in RUN mode.
WinCC flexible Engineering software fails to install or throws a license error
Check that the Automation License Manager (ALM) is installed and that the license key (USB dongle or software license) is present and recognized. Verify the software edition matches the purchased license.
Install or reinstall the Automation License Manager from the WinCC flexible installation media. Insert the license USB dongle or transfer the software license using ALM. Ensure the license edition (Micro, Compact, Standard, or Advanced) matches the installed software.
Alarm events are not being logged or displayed correctly on the HMI
Check the alarm configuration in the WinCC flexible project, including trigger tags, alarm classes, and display settings. Verify that the alarm buffer size is not set to zero and that the correct alarm view object is placed on the screen.
Review and correct alarm tag addresses and trigger conditions in the project. Increase the alarm buffer size under project settings and ensure an alarm view or alarm window object is correctly configured on the relevant HMI screen. Recompile and download the updated project.
Tags show incorrect or frozen values on the HMI at Runtime
Check the communication status indicator in the Runtime. Verify tag addresses and data types match the PLC program. Use the PLC diagnostic tools to confirm the PLC is updating the relevant data areas.
Correct any mismatched tag addresses or data types in the WinCC flexible project. If communication is intermittent, check network cable quality and switch port settings. Ensure the PLC scan cycle is not overloaded, which can delay data updates to the HMI.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page