• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BP07-5AH0 SIMATIC WinCC flexible
    Awaiting product image

    Siemens 6AV6381-2BP07-5AH0 SIMATIC WinCC flexible

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BP07-5AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BP07-5AH0 is a software license package belonging to the SIMATIC WinCC flexible product family, developed by Siemens for engineering and configuring HMI (Human-Machine Interface) applications. This part number corresponds to a WinCC flexible 2007 Compact edition, which provides a streamlined engineering environment for configuring operator panels and touch-based HMI devices within the SIMATIC automation ecosystem. It is a PC-based software tool rather than a hardware panel, delivered as an installable package for use on standard Windows-based engineering workstations.

    WinCC flexible Compact supports configuration of Siemens HMI panels such as the SIMATIC Micro Panels, OP/TP 170, and similar compact operator panel families. The software provides a graphical project editor, tag management, alarm logging, recipe management, and trend display configuration. It integrates directly with SIMATIC STEP 7 for seamless data exchange and symbol import, reducing engineering effort. Communication is supported via MPI, PROFIBUS DP, and serial interfaces depending on the target panel hardware.

    This software is widely used in small to medium-scale machine automation projects across industries such as packaging, food and beverage, plastics processing, and general manufacturing. It is particularly suited for OEMs and machine builders who require a cost-effective HMI engineering tool for compact operator panels. The Compact edition is appropriate for applications where a limited number of process tags and screens are sufficient for operator interaction and machine monitoring.

    Technical Specifications

    Product Family SIMATIC WinCC flexible 2007
    Edition Compact
    Software Type HMI Engineering Software
    License Type Single License
    Target HMI Devices SIMATIC Micro Panels, OP/TP 170, and compatible compact panels
    Communication Interfaces Supported MPI, PROFIBUS DP, Serial (RS-232/RS-422/RS-485)
    STEP 7 Integration Yes, symbol import and project linking supported
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Tag Limit Up to 128 process tags (Compact edition)
    Alarm Classes Bit alarms and analog alarms supported
    Recipe Management Supported
    Trend Display Supported
    Certifications CE

    Common Error Codes and Software Events

    Error 1920
    License not found or license server unreachable during software startup
    Verify that the correct license key is installed using the Automation License Manager. Ensure the USB dongle or software license is properly activated on the engineering PC.
    Error 1722
    Installation error indicating a problem with the Windows Installer package during setup
    Re-run the installer as Administrator. Ensure all prerequisites such as Microsoft .NET Framework and Visual C++ redistributables are installed before retrying.
    Compiler Error: Tag limit exceeded
    The number of configured process tags in the project exceeds the maximum allowed by the Compact license edition
    Reduce the number of tags in the project to within the 128-tag limit, or upgrade to a higher WinCC flexible edition such as Standard or Advanced.
    Communication Error: No connection to HMI device
    The engineering PC cannot establish a connection to the target HMI panel for project download
    Check the physical cable connection (MPI, PROFIBUS, or USB). Verify the correct communication interface is selected in the project transfer settings. Ensure the HMI panel is powered and in transfer mode.
    Runtime Simulation Error
    The integrated simulator fails to start or crashes during project simulation on the engineering PC
    Ensure the PC meets minimum system requirements. Close other resource-intensive applications. Reinstall the WinCC flexible runtime simulation component if the issue persists.
    Project Conversion Error
    An older WinCC flexible project cannot be opened or converted to the current software version
    Use the integrated project migration wizard. Back up the original project before conversion. If conversion fails, check Siemens support for known compatibility issues between versions.

    Frequently Asked Questions

    What HMI panels are compatible with WinCC flexible 2007 Compact?

    WinCC flexible 2007 Compact supports Siemens SIMATIC Micro Panels, OP 73, TP 177 Micro, and other compact operator panels. It does not support the full range of Comfort or Advanced panels, which require higher editions of WinCC flexible or WinCC Advanced.

    Can this software be integrated with SIMATIC STEP 7?

    Yes, WinCC flexible integrates directly with SIMATIC STEP 7, allowing symbol import and shared project management. This reduces configuration effort by enabling tag reuse between the PLC and HMI projects.

    What is the maximum number of process tags supported in the Compact edition?

    The Compact edition supports up to 128 process tags. If a project requires more tags, an upgrade to the Standard or Advanced edition of WinCC flexible is necessary.

    What operating systems are supported for installing WinCC flexible 2007?

    WinCC flexible 2007 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10 or Windows 11 without compatibility workarounds.

    Is a hardware dongle required to run this software?

    Depending on the license variant, either a USB hardware dongle or a software-based license managed through the Siemens Automation License Manager is required. The license must be present on the engineering PC for the software to operate.

    Troubleshooting

    Software fails to start after installation and displays a license error

    Open the Siemens Automation License Manager and check whether a valid license for WinCC flexible Compact is listed and active. Verify the USB dongle is connected if a hardware license is used.

    Transfer or activate the correct license using the Automation License Manager. If using a USB dongle, try a different USB port. Contact Siemens license support if the license appears corrupted or missing.

    Project download to HMI panel fails with a communication timeout

    Check the cable connection between the engineering PC and the HMI panel. Verify the selected transfer interface in WinCC flexible matches the physical connection type (USB, MPI, or PROFIBUS). Confirm the HMI panel is in transfer mode.

    Replace the communication cable if damaged. Set the HMI panel to transfer mode manually via its start center. Ensure the correct COM port or network adapter is selected in the PC settings and WinCC flexible transfer configuration.

    Compiled project reports tag limit exceeded error and will not compile

    Review the tag table in the WinCC flexible project editor and count the total number of configured external process tags. The Compact edition has a hard limit of 128 tags.

    Remove unused or redundant tags to bring the total below 128. Alternatively, upgrade the WinCC flexible license to the Standard edition, which supports a higher tag count.

    Simulation of the HMI project on the PC does not start or crashes immediately

    Check the Windows Event Viewer for application errors related to WinCC flexible runtime. Verify that the PC meets the minimum RAM and CPU requirements for running the simulation environment.

    Ensure at least 1 GB of RAM is available and close background applications. Reinstall the WinCC flexible simulation component via the original installation media by performing a repair installation.

    Existing project from an older WinCC flexible version cannot be opened

    WinCC flexible 2007 may not automatically open projects created in significantly older versions without a migration step. Check the project file version information in the file properties.

    Use the WinCC flexible project migration tool included in the software to convert the older project. Always create a backup of the original project files before attempting migration to avoid data loss.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart