• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BM07-5AH0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BM07-5AH0 WinCC flexible 2007

    € 1.558,00

    Reset
    Clear
    SKU: 6AV6381-2BM07-5AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BM07-5AH0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is used to create visualization projects for operator panels across the SIMATIC portfolio.

    WinCC flexible 2007 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based runtime systems. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes features such as faceplates, scripting via VBScript, alarm management, trend displays, recipe management, and multi-language project support. The engineering tool runs on standard Windows-based PCs and provides a project migration path from ProTool and earlier WinCC flexible versions.

    WinCC flexible 2007 is widely used in manufacturing automation, process industries, and machine building where SIMATIC HMI panels are deployed for operator control and monitoring. It is suitable for applications in automotive production lines, food and beverage processing, packaging machinery, and water treatment facilities. The software enables engineers to design consistent HMI interfaces across multiple panel types from a single engineering environment.

    Technical Specifications

    Software Version WinCC flexible 2007
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single-user license
    Compatible HMI Devices SIMATIC Micro Panels, OP/TP series, Multi Panels, PC Runtime
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Project Migration ProTool, WinCC flexible 2004/2005/2005 SP1
    Languages Supported Multi-language project support
    Series SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes & System Events

    Error 1920
    Software license not found or license key missing during startup
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary.
    Error 1722
    Installation error: Windows Installer package failure during WinCC flexible setup
    Ensure the operating system meets minimum requirements. Run the installer as administrator and disable antivirus software during installation.
    Communication Error
    No connection established between engineering PC and HMI panel during project download
    Check the communication cable and interface settings. Verify that the correct transfer channel (MPI, PROFIBUS, or Ethernet) is configured in both the project and the panel settings.
    Compiler Error
    Project compilation fails due to inconsistent tag or screen references
    Review the compiler output log for specific object references. Delete and re-create the affected tags or screens, and ensure all referenced connections are properly configured.
    License Downgrade Warning
    Installed license does not cover all features used in the current project
    Upgrade the WinCC flexible license to the appropriate edition (Compact, Standard, or Advanced) that covers the required feature set and number of tags.
    Runtime Transfer Error
    Project transfer to HMI panel fails or is interrupted
    Confirm the panel is in transfer mode. Check the physical connection, verify IP address or MPI address settings, and ensure no firewall is blocking the transfer port.
    Migration Error
    Project migration from ProTool or earlier WinCC flexible version fails
    Use the integrated migration wizard and ensure the source project is saved in a compatible format. Check the migration log for unsupported objects and manually recreate them in WinCC flexible 2007.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of SIMATIC HMI devices including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), Multi Panels (MP series), and PC-based runtime systems running WinCC flexible Runtime.

    Which operating systems are compatible with WinCC flexible 2007?

    WinCC flexible 2007 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7 (32-bit editions). It is not natively supported on 64-bit operating systems without compatibility measures.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2007 projects. However, some objects and scripts may require manual rework after migration due to differences in the engineering environments.

    What communication protocols does WinCC flexible 2007 support for PLC connectivity?

    WinCC flexible 2007 supports MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) for communication with SIMATIC S7 PLCs. Additional drivers for third-party controllers may also be available depending on the license edition.

    Is a separate runtime license required to run projects on an HMI panel?

    The engineering license (6AV6381-2BM07-5AH0) covers project creation and configuration. A separate WinCC flexible Runtime license is required for PC-based runtime systems, while dedicated SIMATIC HMI panels include the runtime environment in their firmware.

    Troubleshooting

    WinCC flexible 2007 fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2007 is listed and active on the local machine or license server.

    Transfer or reinstall the license using the ALM tool. Ensure the license matches the installed software version and edition. If the license dongle is used, verify it is properly connected.

    Project download to HMI panel fails with a communication timeout

    Check the physical connection between the PC and the HMI panel. Verify the transfer channel settings in the project match the panel's configured interface (MPI address, PROFIBUS address, or IP address).

    Correct the interface settings in the project transfer dialog. Ensure the HMI panel is set to transfer mode. Replace the communication cable if damaged, and check that no firewall or antivirus software is blocking the connection.

    Compilation errors appear when building the HMI project

    Review the compiler output window for specific error messages referencing tags, screens, or connections. Identify any broken references or missing communication drivers.

    Delete and recreate the affected tags or screen objects. Verify all PLC connections are correctly defined and that tag addresses match the PLC data structure. Save and recompile the project after corrections.

    WinCC flexible 2007 installation fails partway through on Windows 7

    Check the Windows Event Viewer for installation error codes. Confirm that the user account has full administrator privileges and that no conflicting software or previous WinCC installation is present.

    Uninstall any previous WinCC flexible versions using the Siemens uninstall tool. Disable antivirus and User Account Control (UAC) during installation. Run the setup executable as administrator and follow the installation prerequisites checklist.

    Migrated project from ProTool displays missing or incorrect screen objects

    Review the migration log generated during the import process. Identify objects flagged as unsupported or partially migrated, such as custom controls or deprecated tag types.

    Manually recreate unsupported objects in WinCC flexible 2007 using equivalent available components. Update tag addresses and screen layouts as needed to match the original ProTool project functionality.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart