
Siemens 6AV6381-2BK08-0AV0 WinCC flexible 2008
€ 3.495,00
The Siemens 6AV6381-2BK08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment used to develop, commission, and manage HMI (Human-Machine Interface) applications for Siemens operator panels and visualization systems. It is designed for use with the SIMATIC HMI product range and integrates tightly with the broader TIA (Totally Integrated Automation) ecosystem.
WinCC flexible 2008 offers a comprehensive set of engineering tools for creating HMI screens, alarm management, trend displays, recipe management, and user administration. The software supports a wide range of Siemens HMI hardware targets including the TP, OP, MP, and Mobile Panel series. It provides communication drivers for SIMATIC S7-200, S7-300, S7-400, and other third-party controllers via standard protocols such as PROFIBUS, MPI, and Ethernet. The software includes tag management, scripting via VBScript, and project simulation capabilities for offline testing.
WinCC flexible 2008 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, water treatment, and process industries. It is particularly suited for machine-level HMI development where operators require intuitive visualization of process data, alarm handling, and production reporting. The software serves as the primary engineering tool for integrators and OEMs building standardized machine HMI solutions on Siemens hardware platforms.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | HMI Engineering Software |
| License Type | Single-user license |
| Supported HMI Targets | SIMATIC TP, OP, MP, Mobile Panel series |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, S7-1200 (limited) |
| Communication Interfaces | PROFIBUS, MPI, Industrial Ethernet (TCP/IP) |
| Scripting Support | VBScript |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Project Simulation | Integrated offline simulator |
| Alarm Management | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
| User Administration | Supported |
| Series/Product Family | WinCC flexible |
Common Error Codes & System Events
- Event ID: 1000
- Project compilation error — one or more tags or screen objects contain invalid configurations preventing successful project build.
Review the compiler output log, identify the affected tags or screens, and correct the configuration errors before recompiling. - Event ID: 1010
- Communication connection to the target HMI panel could not be established during download.
Verify the PC-to-panel communication interface (MPI, PROFIBUS, or Ethernet), check cable connections, confirm the correct communication driver is selected, and ensure the panel is powered and in transfer mode. - Event ID: 1020
- License not found or license is invalid for the selected software edition.
Check that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary. - Event ID: 1030
- Target HMI device type mismatch — the project is configured for a different HMI panel type than the connected device.
Open the project properties and verify the target device type matches the physical panel. Migrate the project to the correct device type if required. - Event ID: 1040
- Insufficient memory on target HMI panel — the compiled project exceeds the available user memory of the target device.
Reduce the number of screens, images, or data records in the project, or select a target panel with greater user memory capacity. - Event ID: 1050
- Tag limit exceeded — the number of configured tags in the project exceeds the maximum allowed for the selected software edition or target device.
Reduce the number of tags, consolidate tag usage, or upgrade to a higher WinCC flexible edition that supports a greater tag count. - Event ID: 1060
- Runtime error on HMI panel — a script or function configured in the project caused a runtime exception during operation.
Review VBScript functions for syntax errors or invalid object references. Enable script diagnostics and check the panel's alarm buffer for detailed error information. - Event ID: 1070
- Project version incompatibility — the project file was created with a newer or incompatible version of WinCC flexible and cannot be opened.
Upgrade WinCC flexible to the required version, or use the project migration wizard if downgrading to an older format is needed.
Frequently Asked Questions
What HMI hardware is compatible with WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific software edition (Compact, Standard, Advanced, or Comprehensive).
Which controllers can communicate with HMI projects built in WinCC flexible 2008?
The software supports SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS, and Industrial Ethernet. Third-party controllers can also be integrated using available communication drivers.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 is officially supported on Windows XP, Windows Vista, and Windows 7. It is not officially certified for Windows 10, and compatibility issues may arise when running on newer operating systems.
Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, not all features and configurations migrate automatically, and manual adjustments are typically required after migration.
What is the difference between WinCC flexible editions?
WinCC flexible 2008 is available in Compact, Standard, Advanced, and Comprehensive editions, each supporting an increasing number of tags, screens, and target device types. The Comprehensive edition supports the full range of SIMATIC HMI panels and the highest tag counts.
Troubleshooting
Software fails to install or reports a license error after installation
Check the Siemens Automation License Manager (ALM) to confirm whether a valid license for WinCC flexible 2008 is present and correctly assigned to the local machine.
Transfer or reinstall the license using the ALM tool. Ensure the license matches the installed edition (Compact, Standard, Advanced, or Comprehensive). Contact Siemens support if the license key is corrupted.
Project cannot be downloaded to the HMI panel
Verify the communication interface between the engineering PC and the HMI panel. Check that the correct transfer cable or network connection is used and that the panel is set to transfer mode.
Confirm the communication settings in WinCC flexible match the panel's interface (MPI address, PROFIBUS address, or IP address). Restart the panel in transfer mode and retry the download.
Compiled project size exceeds panel memory limit
Review the project's memory usage report generated during compilation. Identify large image files, excessive screen counts, or high data record volumes contributing to the oversized project.
Optimize image files by reducing resolution or color depth, remove unused screens and tags, and reduce recipe data record counts. Consider targeting a panel with larger user memory if optimization is insufficient.
VBScript functions do not execute correctly at runtime on the panel
Test the script logic using the integrated WinCC flexible simulator on the engineering PC. Check for syntax errors, undefined variables, or references to unsupported objects on the target panel.
Correct any script errors identified during simulation. Ensure that all scripted functions use only objects and methods supported by the target HMI panel's runtime environment. Recompile and re-download the project.
WinCC flexible 2008 crashes or becomes unstable on the engineering PC
Check the PC's operating system compatibility (Windows XP, Vista, or 7 recommended). Review Windows Event Viewer logs for application errors related to the WinCC flexible process.
Ensure all Siemens-recommended service packs and patches for WinCC flexible 2008 are installed. Disable conflicting software such as antivirus real-time scanning on project directories. Reinstall the software if instability persists.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page


