• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2AA08-0AX3 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2AA08-0AX3 WinCC flexible 2008

    € 845,57

    Reset
    Clear
    SKU: 6AV6381-2AA08-0AX3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2AA08-0AX3 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of operator panels.

    WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It provides a library of pre-built faceplates, multilingual project support, and integration with STEP 7 for seamless project data exchange. The 2008 edition introduced improved performance, extended panel support, and enhanced diagnostics capabilities.

    WinCC flexible 2008 is widely used in manufacturing automation, process control, machine building, and plant engineering across industries such as automotive, food and beverage, pharmaceuticals, and energy. It is suitable for applications requiring scalable HMI solutions ranging from small standalone operator panels to distributed multi-panel installations. The software's compatibility with the broad SIMATIC panel portfolio makes it a standard choice for system integrators and OEMs building SIMATIC-based control systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    Series/Product Family SIMATIC WinCC flexible
    License Type Single-user engineering license
    Supported PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Integration STEP 7 integration supported
    Language Support Multilingual project support
    Certifications CE
    Software Type HMI Engineering and Runtime Configuration Software

    Common Error Codes & System Events

    Event ID: 1000
    License not found or invalid license key detected during startup
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary.
    Event ID: 1010
    Communication error between WinCC flexible runtime and the connected PLC
    Check the communication cable and interface settings. Verify the PLC address, baud rate, and protocol settings in the project configuration.
    Event ID: 1020
    Tag read/write error — a configured tag cannot be accessed on the controller
    Confirm the tag address exists in the PLC program and that the data type matches the WinCC flexible tag configuration.
    Event ID: 1030
    Alarm logging buffer overflow — the alarm buffer has reached its maximum capacity
    Acknowledge and clear pending alarms. Increase the alarm buffer size in the project settings or archive alarms to an external database.
    Event ID: 1040
    Recipe data transfer error — recipe could not be written to or read from the PLC
    Check recipe tag assignments and ensure the PLC memory area is accessible. Verify that the recipe data types match the PLC variable types.
    Event ID: 1050
    Project compilation error — the project contains configuration inconsistencies
    Review the validation output in the WinCC flexible engineering environment. Correct all flagged errors in tag names, screen objects, or communication settings before recompiling.
    Event ID: 1060
    Runtime startup failure — WinCC flexible runtime could not initialize
    Check system resources (RAM, disk space) on the HMI device or PC. Reinstall the runtime software if the issue persists and verify OS compatibility.

    Frequently Asked Questions

    Which PLC families are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as certain third-party controllers via OPC communication.

    What operating systems does WinCC flexible 2008 support?

    WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7 (32-bit editions). It is not natively supported on Windows 10 or later without compatibility measures.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects, though some manual rework may be required for advanced configurations.

    Does this license include both engineering and runtime functionality?

    The 6AV6381-2AA08-0AX3 is an engineering software license. Runtime licenses for PC-based systems are managed separately through the Automation License Manager.

    What communication protocols does WinCC flexible 2008 support?

    WinCC flexible 2008 supports MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP), and OPC DA for communication with PLCs and other automation devices.

    Troubleshooting

    WinCC flexible 2008 fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is present and not expired or corrupted.

    Transfer or reinstall the license using the ALM tool. If the license dongle is used, ensure it is properly connected to the USB port and recognized by the operating system.

    Runtime loses communication with the PLC intermittently

    Check the physical connection (MPI cable, PROFIBUS connector, or Ethernet cable). Review the event log in WinCC flexible for communication fault entries and note the frequency and timing of dropouts.

    Replace or reseat the communication cable. Verify the PLC station address and communication parameters match the project settings. Check for network interference or address conflicts on Ethernet-based setups.

    Project compilation fails with multiple validation errors

    Open the validation output window in the WinCC flexible engineering environment and review each listed error. Common causes include duplicate tag names, missing screen references, or incompatible data types.

    Correct each flagged error systematically. Ensure all tag addresses are valid for the connected PLC type and that all referenced screens and templates exist within the project.

    Alarm display does not show active alarms during runtime

    Check the alarm class configuration and verify that the alarm tags are correctly linked to PLC bit addresses. Confirm that the alarm view object on the screen is configured to display the correct alarm classes.

    Correct the alarm tag addresses and ensure the PLC program is setting the expected bits. Reconfigure the alarm view object if necessary and recompile and download the project to the HMI device.

    Recipe values are not transferred correctly to the PLC

    Compare the recipe tag data types in WinCC flexible with the corresponding PLC variable data types. Check that the PLC memory area used for recipe transfer is not write-protected.

    Align the data types between the recipe configuration and the PLC program. Ensure the PLC data block or memory area is accessible and not locked by another program element during the transfer.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart