• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-1BD01-1AX0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-1BD01-1AX0 WinCC flexible 2007

    € 1.806,00

    Reset
    Clear
    SKU: 6AV6381-1BD01-1AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-1BD01-1AX0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2007 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based runtime systems. The software includes tools for screen design, alarm management, recipe handling, trend displays, and user administration. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and other Siemens PLC families. The 2007 version introduced improved performance, expanded device support, and enhanced project migration capabilities from earlier WinCC flexible versions.

    WinCC flexible 2007 is widely used in manufacturing automation, process industries, and machine building applications where operator visualization and control are required. It is suitable for industries such as automotive, food and beverage, chemical processing, and packaging, where reliable HMI engineering software is needed to configure and maintain operator interfaces. The software's scalability makes it applicable to both small standalone machine panels and larger distributed HMI architectures.

    Technical Specifications

    Software Version WinCC flexible 2007
    Product Family SIMATIC WinCC flexible
    License Type Engineering Software License
    Compatible HMI Devices SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based HMI
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200 (via migration)
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet, USB
    Operating System Windows XP, Windows Vista, Windows 7
    Alarm Management Supported
    Recipe Management Supported
    Trend Display Supported
    User Administration Supported
    Project Migration Supported from earlier WinCC flexible versions
    Certifications CE

    Common Error Codes & System Events

    Error 1
    License not found or invalid license key detected during software startup
    Verify the license dongle or software license is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and re-transfer if necessary.
    Error 2
    Communication error between WinCC flexible engineering station and HMI device during project transfer
    Check the physical connection (USB, Ethernet, or MPI/PROFIBUS cable). Verify the correct communication channel and device address are configured in the transfer settings.
    Error 3
    Project compilation error due to inconsistent or missing tag references
    Open the project in WinCC flexible, navigate to the compiler output window, and resolve all reported tag or screen object inconsistencies before retransferring.
    Error 4
    Runtime startup failure on HMI device after project download
    Check that the WinCC flexible Runtime version on the HMI device matches the engineering software version. Update the runtime image on the device if a version mismatch exists.
    Error 5
    Database error or project file corruption detected when opening a project
    Restore the project from a recent backup. If no backup is available, use the WinCC flexible project repair utility or contact Siemens support for file recovery options.
    Error 6
    Insufficient memory on target HMI device for the compiled project
    Reduce the project size by optimizing graphics, reducing the number of screens or tags, or compressing images. Alternatively, use an HMI device with greater memory capacity.
    Error 7
    Alarm logging or data logging failure due to storage medium error on HMI device
    Check the storage medium (internal flash, memory card) on the HMI device. Format or replace the storage medium and reconfigure the logging settings in the project.

    Frequently Asked Questions

    Which SIMATIC HMI devices are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of SIMATIC HMI devices including Micro Panels (TP 170 Micro, OP 73 Micro), Mobile Panels, Operator Panels (OP 77, TP 177, OP 177), Multi Panels (MP 277, MP 377), and PC-based runtime systems running WinCC flexible Runtime.

    Is WinCC flexible 2007 compatible with SIMATIC S7-1200 or S7-1500 PLCs?

    WinCC flexible 2007 was not originally designed for S7-1200 or S7-1500 PLCs. For these newer controllers, Siemens recommends using TIA Portal with WinCC (TIA Portal). Limited connectivity may be possible via Ethernet drivers, but full integration is not supported.

    What operating systems are supported for installing WinCC flexible 2007?

    WinCC flexible 2007 supports installation on Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not officially supported on Windows 8, Windows 10, or Windows 11.

    Can projects created in earlier versions of WinCC flexible be migrated to WinCC flexible 2007?

    Yes, WinCC flexible 2007 includes a project migration tool that allows projects created in earlier versions such as WinCC flexible 2004 and 2005 to be converted and opened in the 2007 version.

    What is the Automation License Manager and is it required for WinCC flexible 2007?

    The Automation License Manager (ALM) is Siemens' license management tool required to manage and validate software licenses for WinCC flexible 2007. It must be installed and a valid license must be present for the engineering software to operate.

    Troubleshooting

    WinCC flexible 2007 fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2007 is present and not expired or corrupted.

    Transfer a valid license using the ALM from a license storage medium or USB dongle. If the license is shown as defective, contact Siemens support for license recovery.

    Project transfer to HMI device fails with a connection timeout

    Verify the physical cable connection and check the transfer channel settings in WinCC flexible (USB, Ethernet, or MPI/PROFIBUS). Confirm the HMI device is in transfer mode.

    Switch the HMI device to transfer mode manually via the Start Center or Control Panel on the device. Ensure the correct IP address or device address is configured in the WinCC flexible transfer settings.

    Compiled project reports errors related to undefined or missing tags

    Review the compiler output log in WinCC flexible to identify which tags or screen objects have broken references. This typically occurs after renaming or deleting tags that are still referenced in screens or scripts.

    Navigate to each reported error in the compiler log, update or reassign the broken tag references in the affected screens or scripts, and recompile the project.

    HMI device displays 'Runtime not found' or fails to load the project after download

    Check the runtime version installed on the HMI device via the device's Start Center or Control Panel. Compare it with the version used in the WinCC flexible 2007 engineering software.

    Update the HMI device runtime image to match the engineering software version by performing a firmware update using WinCC flexible or ProSave. Retransfer the project after the update.

    WinCC flexible 2007 installation fails or crashes during setup on Windows 7

    Check the Windows Event Viewer for installation error codes. Verify that all prerequisites such as .NET Framework and MSXML are installed and that the user account has administrator privileges.

    Install all required prerequisites listed in the WinCC flexible 2007 readme file before running the setup. Disable antivirus software temporarily during installation and ensure the installation is run as a local administrator.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart