
Siemens 6AV6372-2DF07-0FX0 SIMATIC WinCC flexible
€ 5.649,00
The Siemens 6AV6372-2DF07-0FX0 is a software license for SIMATIC WinCC flexible 2007, Siemens' scalable HMI engineering software platform designed for configuring and commissioning operator panels and HMI systems within the SIMATIC automation environment. This product belongs to the WinCC flexible product family, which serves as the engineering tool for the full range of SIMATIC HMI panels including the TP, OP, MP, and Mobile Panel series. It provides a unified engineering environment for creating visualization projects ranging from small stand-alone operator panels to distributed multi-panel SCADA systems.
WinCC flexible 2007 offers a comprehensive set of engineering tools including a graphical editor, tag management, alarm logging, trend displays, recipe management, and report generation. The software supports multiple communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs as well as third-party controllers via standard protocols. It features a library of pre-built faceplates and symbols, project migration tools from ProTool and earlier WinCC flexible versions, and simulation capabilities for offline testing of HMI projects without physical hardware.
SIMATIC WinCC flexible 2007 is used extensively in manufacturing, process automation, food and beverage, automotive, and machine building industries wherever SIMATIC HMI panels are deployed. It is the standard engineering tool for system integrators and OEMs building machines with Siemens HMI hardware, enabling consistent project management across multiple panel types and sizes. The software is particularly suited for applications requiring centralized project engineering with distribution to multiple operator stations across a production facility.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| Series/Product Family | SIMATIC WinCC flexible |
| License Type | Single-user engineering software license |
| Supported HMI Hardware | SIMATIC TP, OP, MP, Mobile Panel series |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200, third-party via standard drivers |
| Operating System | Windows XP Professional, Windows Vista, Windows 7 |
| Communication Protocols | MPI, PROFIBUS DP, PROFINET, Ethernet, RS-232 |
| Project Migration | ProTool, WinCC flexible 2004/2005/2006 |
| Simulation | Offline project simulation without physical hardware |
| Languages Supported | Multi-language project engineering |
| Certifications | CE |
Common Error Codes & System Events
- Configuration Error
- The project configuration contains invalid or missing tag references, preventing compilation.
Open the project in WinCC flexible, run the consistency check under Project menu, and resolve all reported tag or connection errors before recompiling. - Communication Error
- The engineering PC cannot establish a connection to the target HMI panel during download.
Verify the communication cable and interface settings. Ensure the correct transfer channel (MPI, PROFIBUS, or Ethernet) is selected in the panel's transfer settings and matches the PC configuration. - Transfer Error
- Project download to the HMI panel fails or is interrupted mid-transfer.
Check available memory on the target panel. Ensure no other application is using the communication port. Retry the transfer after restarting both the panel and the engineering PC. - License Error
- WinCC flexible reports a missing or invalid license, preventing project compilation or runtime generation.
Use the Siemens Automation License Manager (ALM) to verify the license is correctly installed and assigned to the local machine. Reinstall the license if necessary. - Consistency Check Error
- The project fails the internal consistency check due to mismatched screen objects, undefined variables, or unsupported functions for the target panel type.
Run the consistency check from the Project menu, review all listed errors, and correct object references, tag assignments, or replace unsupported functions with compatible alternatives. - Simulation Runtime Error
- The integrated simulator crashes or fails to start during offline project testing.
Ensure the PC meets the minimum system requirements, close other resource-intensive applications, and verify that the correct runtime version matching the project's target panel is installed. - Migration Error
- Importing a project from ProTool or an earlier WinCC flexible version results in conversion errors or missing objects.
Review the migration log generated during import, manually recreate unsupported objects, and verify all tag connections and screen layouts after migration is complete.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2007?
WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the TP 170, TP 177, OP 177, MP 277, MP 377, Mobile Panel 177, and other panels in the SIMATIC HMI family. The specific panels available depend on the edition of the software installed.
Can WinCC flexible 2007 projects be migrated to TIA Portal WinCC?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, some manual rework may be required as not all objects and functions migrate automatically.
What communication interfaces does WinCC flexible 2007 support for PLC connectivity?
WinCC flexible 2007 supports MPI, PROFIBUS DP, PROFINET, Industrial Ethernet, and serial RS-232 interfaces, along with a wide range of communication drivers for both Siemens and third-party PLCs.
Is an Automation License Manager required to run WinCC flexible 2007?
Yes, the Siemens Automation License Manager (ALM) must be installed on the engineering PC to manage and validate the WinCC flexible software license.
Can multiple HMI panel types be configured within a single WinCC flexible project?
Yes, WinCC flexible 2007 supports multi-panel projects, allowing engineers to configure different HMI panel types within a single project and share tags, alarms, and other resources across panels.
Troubleshooting
Project download to HMI panel fails with a communication timeout
Check the physical connection between the PC and the HMI panel. Verify the selected transfer channel in WinCC flexible matches the panel's active transfer mode (MPI, PROFIBUS, or Ethernet). Confirm the panel is in transfer mode.
Set the HMI panel to transfer mode manually via the panel's Start Center or Control Panel. Ensure the correct COM port or network adapter is selected in the WinCC flexible transfer settings and retry the download.
WinCC flexible software fails to start after installation
Check the Windows Event Viewer for application errors related to WinCC flexible. Verify that the Automation License Manager is installed and that a valid license is present.
Reinstall the Automation License Manager and confirm the license is correctly assigned. If the issue persists, perform a repair installation of WinCC flexible 2007 using the original installation media.
Consistency check reports numerous undefined tag errors after project migration
Open the tag management view and filter for tags with no assigned connection or address. This typically occurs when the source PLC connection was not correctly mapped during migration.
Reassign the PLC connection to each affected tag or use the global tag replacement function to remap tags in bulk. Verify all PLC variable addresses match the target controller's data structure.
Simulation does not reflect the latest project changes
The simulator may be running a cached version of the project. Check whether the project was saved and compiled successfully before launching the simulation.
Save and fully recompile the project using the Project menu, then restart the simulator. Ensure no compilation errors exist before running the simulation.
HMI panel displays 'No connection to PLC' at runtime after project download
Verify the PLC communication parameters configured in WinCC flexible match the actual PLC settings, including station address, subnet, and protocol. Check physical cabling between the HMI panel and the PLC.
Correct the communication parameters in the WinCC flexible project connection settings, redownload the project to the panel, and verify the PLC is powered on and in RUN mode with the correct network address.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page



