• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF00-0HY0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-2DF00-0HY0 SIMATIC WinCC

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6372-2DF00-0HY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF00-0HY0 is a software license package belonging to the SIMATIC WinCC (Windows Control Center) family, Siemens' SCADA and HMI configuration and runtime software platform. This part number corresponds to a WinCC runtime or option package designed for use on PC-based HMI systems running under Microsoft Windows. It provides the software infrastructure for creating, configuring, and operating process visualization applications in industrial environments.

    The WinCC software associated with 6AV6372-2DF00-0HY0 supports a wide range of communication interfaces including PROFIBUS, PROFINET, MPI, and OPC/OPC UA, enabling connectivity to SIMATIC S7 PLCs and third-party controllers. The platform offers tag-based licensing, scripting via VBScript and C-Script, alarm management, trend displays, and historical data archiving. It integrates with the broader Siemens TIA Portal ecosystem and supports redundancy configurations for high-availability applications.

    This WinCC software package is used across process industries such as water and wastewater treatment, chemical and pharmaceutical production, energy management, and manufacturing automation. It is suited for applications requiring centralized supervisory control, data acquisition, and visualization on standard industrial PC hardware. The software is commonly deployed in control rooms and operator stations where reliable, scalable process monitoring is required.

    Technical Specifications

    Software Platform SIMATIC WinCC
    Product Type HMI/SCADA Software License
    Operating System Compatibility Microsoft Windows (Industrial)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Scripting Support VBScript, C-Script
    Series/Product Family SIMATIC WinCC
    Integration TIA Portal compatible
    Archiving Historical data archiving supported
    Redundancy Redundancy configuration supported
    Alarm Management Integrated alarm and event logging
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure — the runtime process could not be initialized correctly.
    Check Windows Event Viewer for detailed error messages. Verify that all required WinCC services are running and that the license dongle or software license is correctly installed.
    Event ID: 1000001
    License not found or invalid — WinCC cannot detect a valid license for the installed software version.
    Ensure the SIMATIC license (via Automation License Manager) is correctly transferred to the target PC. Check that the USB license key is connected and recognized by the system.
    Event ID: 1000002
    Database connection error — WinCC cannot connect to the underlying SQL Server database.
    Verify that Microsoft SQL Server (SIMATIC SQL) is running. Restart the SQL Server service and check database integrity using the WinCC project migration tool if necessary.
    Event ID: 1000003
    Communication channel fault — the configured communication driver cannot establish a connection to the PLC.
    Check physical network connections and PLC address settings. Verify the channel configuration in WinCC Explorer and confirm the PLC is online and reachable.
    Event ID: 1000004
    Tag update failure — one or more process tags are not being updated from the connected controller.
    Check the tag connection settings in WinCC Tag Management. Verify PLC program is running and the relevant data blocks or addresses are accessible.
    Event ID: 1000005
    Archive overflow — the process or alarm archive has exceeded its configured size limit.
    Increase the archive size limit in the WinCC Archive Manager settings or configure automatic archiving and backup to prevent overflow.
    Event ID: 1000006
    Script runtime error — a VBScript or C-Script action has encountered an execution error.
    Open the WinCC Script Diagnostics tool to identify the faulty script and line number. Correct the script logic and re-test in the WinCC Graphics Designer.
    Event ID: 1000007
    Redundancy switchover event — the active WinCC server has failed and the standby server has taken over.
    Investigate the cause of the primary server failure. Check hardware health, network connectivity, and Windows system logs. Restore the primary server and re-synchronize the redundancy pair.

    Frequently Asked Questions

    What type of product is the Siemens 6AV6372-2DF00-0HY0?

    It is a SIMATIC WinCC software license package used for PC-based HMI and SCADA visualization. It provides runtime and/or configuration capabilities for industrial process monitoring applications.

    Which PLCs are compatible with this WinCC software?

    The software is compatible with SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFIBUS, PROFINET, and MPI communication channels. OPC and OPC UA connectivity also allows integration with third-party controllers.

    Does this WinCC package support TIA Portal integration?

    Yes, SIMATIC WinCC is compatible with the Siemens TIA Portal engineering framework, allowing unified project configuration alongside SIMATIC PLCs and other automation components.

    Is a hardware dongle required to run this software?

    WinCC licensing is managed through the Siemens Automation License Manager (ALM). Depending on the specific license type, a USB license key (dongle) or a software-based license may be required.

    Can WinCC be used in a redundant server configuration?

    Yes, WinCC supports server redundancy configurations where a standby server automatically takes over if the primary server fails, ensuring high availability for critical process visualization applications.

    Troubleshooting

    WinCC Runtime fails to start after PC reboot

    Check the Windows Services panel to verify that SIMATIC SQL Server and WinCC-related services are set to start automatically. Review the Windows Event Viewer Application log for specific error codes.

    Set all required WinCC and SQL Server services to Automatic startup. If a license error is reported, reconnect the USB license dongle and use the Automation License Manager to verify license validity.

    Process tags show no value updates in Runtime

    Open WinCC Tag Management and check the connection status of the communication channel. Verify the PLC IP address or PROFIBUS address matches the configured channel settings.

    Correct the channel configuration in WinCC Explorer. Confirm the PLC is in RUN mode and the network cable or PROFIBUS connection is physically intact. Restart the WinCC channel driver if necessary.

    WinCC project cannot be opened and reports database error

    The underlying SIMATIC SQL Server database may be corrupted or the SQL Server service may not be running. Check SQL Server status via Windows Services.

    Restart the SIMATIC SQL Server service. If the project database is corrupted, use the WinCC project migration or repair tool. As a last resort, restore the project from a recent backup.

    Alarm archive fills up rapidly and generates overflow warnings

    Check the WinCC Alarm Logging configuration for archive size limits and retention periods. Excessive alarm generation from the PLC may also be contributing to rapid archive growth.

    Increase the maximum archive size or reduce the retention period in the Alarm Logging editor. Investigate the root cause of high alarm rates in the PLC program and suppress nuisance alarms where appropriate.

    Graphics screens display incorrectly or fail to load in Runtime

    Check whether all required WinCC Graphics Designer objects and ActiveX controls are properly installed. Verify that the project was compiled without errors before switching to Runtime mode.

    Recompile the WinCC project in Graphics Designer and resolve any reported errors. Ensure all required software components and service packs are installed on the PC. Re-activate Runtime after a successful compilation.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart