• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-1HD08-0AX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-1HD08-0AX0 SIMATIC WinCC

    € 1.338,18

    Reset
    Clear
    SKU: 6AV6372-1HD08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-1HD08-0AX0 is a software license package for SIMATIC WinCC, Siemens' professional SCADA and HMI runtime software platform. This part number corresponds to a WinCC Runtime license with a specific power tag count, designed to operate on standard industrial PCs and panel PCs running Microsoft Windows. WinCC is part of the broader Siemens SIMATIC automation software family and serves as a central visualization and process control solution.

    WinCC provides a comprehensive set of features including process visualization, alarm management, trend display, reporting, and historical data archiving. It supports a wide range of communication interfaces including PROFIBUS, PROFINET, MPI, and OPC/OPC UA, enabling connectivity to SIMATIC S7 PLCs and third-party controllers. The software includes a powerful scripting environment (VBScript and C-Script), a tag management system, and supports redundant server configurations for high-availability deployments. The runtime environment is optimized for stable, long-term industrial operation.

    SIMATIC WinCC is widely deployed in process industries such as chemical, pharmaceutical, water treatment, and energy management, as well as in discrete manufacturing environments including automotive assembly and machine tool operations. Its scalability from small single-station installations to large distributed multi-server architectures makes it suitable for both standalone machine-level HMI applications and plant-wide SCADA systems. Integration with Siemens TIA Portal and the broader Totally Integrated Automation ecosystem further extends its applicability in modern industrial environments.

    Technical Specifications

    Software Platform SIMATIC WinCC Runtime
    Operating System Microsoft Windows (industrial PC / panel PC)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC, OPC UA
    Scripting Support VBScript, C-Script
    Alarm Management Integrated alarm logging and archiving
    Trend Display Online and historical trend visualization
    Redundancy Support Server redundancy supported
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Series/Product Family SIMATIC WinCC
    License Type Runtime software license
    Certifications CE
    Integration TIA Portal compatible

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure. The runtime process could not be initialized correctly.
    Check Windows Event Viewer for underlying errors. Verify that all required WinCC services are running and that the license dongle or software license is correctly installed.
    Event ID: 1001
    Communication channel to PLC is interrupted or unavailable.
    Verify network connectivity to the PLC. Check PROFIBUS/PROFINET configuration and ensure the correct channel driver is loaded in WinCC.
    Event ID: 10241
    License not found or license count exceeded.
    Ensure the correct WinCC license (matching the tag count) is installed. Check the Siemens Automation License Manager (ALM) for license status.
    Event ID: 10000
    Tag archiving error. Historical data could not be written to the archive database.
    Check available disk space on the archive drive. Verify that the SQL Server or WinCC database service is running correctly.
    Event ID: 10200
    Alarm logging system error. Alarm messages are not being recorded.
    Check the alarm logging configuration in WinCC Explorer. Ensure the alarm database is accessible and not corrupted.
    Event ID: 20000
    Script runtime error. A VBScript or C-Script action has encountered an execution error.
    Open the WinCC Script Debugger to identify the faulty script. Review script logic for null references, type mismatches, or missing object references.
    Event ID: 30000
    Graphics runtime error. A picture or screen object failed to load or render.
    Verify that all referenced picture files exist in the WinCC project directory. Re-compile the project and restart the runtime.

    Frequently Asked Questions

    What tag count does the 6AV6372-1HD08-0AX0 license support?

    The 6AV6372-1HD08-0AX0 is a WinCC Runtime license. The specific power tag count for this part number should be verified against the Siemens SIMATIC WinCC ordering data, as tag count variants are encoded in the part number suffix.

    Is this WinCC license compatible with TIA Portal?

    Yes, SIMATIC WinCC Runtime is compatible with the Siemens TIA Portal engineering environment, allowing integrated project configuration alongside SIMATIC PLCs.

    What PLCs can WinCC communicate with using this software?

    WinCC supports communication with SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFIBUS, PROFINET, and MPI. Third-party PLCs can be connected via OPC or OPC UA interfaces.

    Does WinCC Runtime support redundant server configurations?

    Yes, WinCC Runtime supports server redundancy, allowing a standby server to take over automatically in the event of a primary server failure, ensuring high availability of the visualization system.

    What operating system is required to run this WinCC Runtime license?

    WinCC Runtime requires a compatible version of Microsoft Windows, typically Windows 10 IoT Enterprise or Windows Server, running on an industrial PC or Siemens panel PC. Refer to the WinCC compatibility list for the specific OS version supported by this release.

    Troubleshooting

    WinCC Runtime fails to start after installation

    Check the Siemens Automation License Manager (ALM) to confirm the license is correctly transferred and active. Review the Windows Event Log and WinCC diagnostic files for startup errors.

    Ensure the correct license matching the installed WinCC version and tag count is active in ALM. Reinstall the WinCC Runtime software if system files are corrupted, and verify that all prerequisite software components (SQL Server, .NET Framework) are installed.

    No communication between WinCC and the SIMATIC PLC

    Verify the channel driver configuration in WinCC Explorer. Check network connectivity using ping or SIMATIC NET diagnostics. Confirm that the PLC IP address and rack/slot settings are correctly configured in the WinCC tag management.

    Correct the channel driver settings and PLC connection parameters. Ensure PROFINET or PROFIBUS adapters are properly installed and configured on the PC. Restart the WinCC communication service after making changes.

    Historical trend data is not being recorded or is missing

    Check available disk space on the drive hosting the WinCC archive. Verify that the SQL Server service is running and that the WinCC archive database is not corrupted or full.

    Free up disk space or expand the archive storage. Restart the SQL Server service and the WinCC archive service. If the database is corrupted, restore from a backup or reinitialize the archive with a new database.

    Alarm messages are not appearing in the alarm view at runtime

    Check the alarm logging configuration in WinCC Explorer to ensure alarm classes and message blocks are correctly defined. Verify that the alarm logging runtime is active and connected to the correct data source.

    Recompile the alarm configuration and restart the WinCC Runtime. Ensure that the alarm database path is accessible and that the alarm logging service has write permissions to the target directory.

    WinCC project screens load slowly or display rendering errors

    Check system resource utilization (CPU, RAM, disk I/O) on the runtime PC. Identify any missing or broken graphic object references in the project using WinCC consistency check.

    Optimize project graphics by reducing the number of dynamic objects per screen. Upgrade PC hardware if resources are insufficient. Repair broken object references and recompile the project before restarting the runtime.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart