• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-1HC08-0AX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-1HC08-0AX0 SIMATIC WinCC

    € 658,70

    Reset
    Clear
    SKU: 6AV6372-1HC08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-1HC08-0AX0 is a WinCC Runtime software license belonging to Siemens' SIMATIC WinCC product family, a professional SCADA and HMI visualization platform. This part number corresponds to a WinCC Runtime license for 128 power tags, enabling process visualization and operator control on PC-based HMI systems. It is part of the broader SIMATIC WinCC V7 software suite developed by Siemens for industrial process monitoring and control.

    WinCC Runtime with 128 power tags provides a scalable visualization environment capable of displaying real-time process data, alarms, trends, and reports. The software supports OPC DA/UA communication standards, enabling integration with a wide range of PLCs and field devices beyond the Siemens ecosystem. It includes a comprehensive alarm management system, historical data logging, and a scripting interface based on VBScript and C for custom automation logic. The platform supports redundancy configurations and multi-client/server architectures for high-availability applications.

    This WinCC Runtime license is widely deployed in manufacturing plants, water and wastewater treatment facilities, energy management systems, and building automation environments. The 128 power tag tier makes it suitable for small to medium-scale installations where a limited number of process variables need to be monitored and controlled from a central PC-based operator station. Its compatibility with the broader Siemens TIA Portal and SIMATIC S7 PLC families makes it a natural choice for sites already operating within the Siemens automation ecosystem.

    Technical Specifications

    Software Type SCADA / HMI Runtime Software
    Product Family SIMATIC WinCC V7
    Power Tags 128
    License Type Runtime License
    Communication Protocols OPC DA, OPC UA, PROFIBUS, PROFINET, S7 Protocol
    Scripting Support VBScript, C
    Redundancy Support Yes (server redundancy capable)
    Alarm Management Yes, integrated alarm logging and archiving
    Trend/Historical Data Yes, process value archiving
    Multi-Client Support Yes
    Operating System Compatibility Windows Server / Windows 10 (64-bit)
    Certifications CE
    Series SIMATIC WinCC V7

    Common Error Codes and System Events

    Event ID: 1000001
    WinCC Runtime startup failure — the runtime could not initialize correctly, often due to a missing or invalid license.
    Verify that the license is correctly installed using the Siemens License Manager (Automation License Manager). Reinstall the license if necessary.
    Event ID: 1000002
    Tag communication error — one or more power tags cannot establish communication with the connected PLC or data source.
    Check the channel driver configuration, verify PLC connection parameters (IP address, rack/slot), and confirm the PLC is online and reachable.
    Event ID: 1000010
    Archive database error — the process value or alarm archive cannot be written to, often due to disk space or SQL Server issues.
    Check available disk space on the archive drive, verify that the Microsoft SQL Server service is running, and check WinCC database integrity using the WinCC Configuration Studio.
    Event ID: 1000020
    License tag count exceeded — the number of active power tags in the project exceeds the licensed limit of 128.
    Reduce the number of active power tags in the project to within the 128-tag limit, or upgrade to a higher tag-count WinCC Runtime license.
    Event ID: 1000030
    OPC server connection lost — the WinCC OPC DA or OPC UA server connection to a client or external system has been interrupted.
    Check network connectivity between the OPC server and client, verify OPC server configuration, and restart the OPC service if necessary.
    Event ID: 1000050
    Redundancy switchover event — WinCC has detected a failure on the primary server and has switched operation to the redundant server.
    Investigate the cause of the primary server failure (hardware, network, or software fault), restore the primary server, and perform a manual synchronization if automatic resynchronization does not occur.
    Event ID: 1000060
    Script runtime error — a VBScript or C script within the WinCC project has encountered an execution error.
    Open the WinCC Script Diagnostics tool to identify the faulty script and line number. Correct the script logic and redeploy the project.

    Frequently Asked Questions

    What is the tag limit for the 6AV6372-1HC08-0AX0 WinCC Runtime license?

    This license supports up to 128 power tags, which defines the maximum number of process variables that can be actively communicated and archived within the WinCC Runtime environment.

    Is this WinCC Runtime license compatible with TIA Portal projects?

    WinCC V7 Runtime is a standalone SCADA platform and is not directly integrated into TIA Portal. TIA Portal uses WinCC Advanced or WinCC Professional for panel and PC-based HMI. WinCC V7 is configured using its own WinCC Configuration Studio environment.

    What PLCs can WinCC Runtime communicate with using this license?

    WinCC Runtime supports communication with Siemens SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via the S7 protocol, as well as third-party devices via OPC DA, OPC UA, and various channel drivers.

    Does this license support redundant server configurations?

    Yes, WinCC V7 Runtime supports server redundancy. However, a separate redundancy license and a second server installation are required to enable the redundancy functionality.

    What operating system is required to run this WinCC Runtime software?

    WinCC V7 Runtime requires a compatible 64-bit Windows operating system, such as Windows 10 (specific editions) or Windows Server 2016/2019, along with Microsoft SQL Server for database archiving functions.

    Troubleshooting

    WinCC Runtime fails to start and displays a license error

    Open the Siemens Automation License Manager and check whether a valid WinCC Runtime license for 128 tags is present and not expired or transferred to another machine.

    Reinstall or transfer the license using the Automation License Manager. Ensure the license dongle (if used) is connected, or verify the software license is bound to the correct hardware fingerprint.

    Process tags show no values or display connection errors in the Runtime

    Check the WinCC channel driver configuration for the connected PLC. Verify the PLC IP address, rack and slot settings, and confirm the PLC is powered on and reachable via the network.

    Correct the channel driver parameters in WinCC Configuration Studio, ensure the PC firewall is not blocking S7 communication ports, and restart the WinCC Runtime after making changes.

    Alarm archiving or trend data is not being recorded

    Check whether the Microsoft SQL Server service (used by WinCC for archiving) is running. Also verify available disk space on the drive where WinCC archives are stored.

    Start the SQL Server service if it is stopped, free up disk space if necessary, and check the WinCC archive configuration for correct storage paths and cycle times.

    WinCC Runtime project loads but screens appear blank or graphics are missing

    This may indicate a corrupted project file, missing graphic objects, or a display driver incompatibility on the host PC.

    Validate the project in WinCC Configuration Studio for errors, reinstall any missing WinCC components, and ensure the PC graphics driver is up to date and compatible with the WinCC version installed.

    OPC client cannot connect to WinCC OPC server

    Check Windows DCOM settings, firewall rules, and user account permissions on the WinCC server PC, as OPC DA communication relies on DCOM configuration.

    Configure DCOM permissions using dcomcnfg.exe to allow remote access for the OPC client user account, open the required firewall ports, and verify that the WinCC OPC server service is running.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart