
Siemens 6AV6371-2BN08-0AX0 WinCC flexible 2008
€ 1.100,47
The Siemens 6AV6371-2BN08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' SIMATIC HMI software portfolio. This engineering software is used to configure, program, and commission SIMATIC HMI panels and operator interface devices within the TIA (Totally Integrated Automation) ecosystem. It represents a specific edition of the WinCC flexible 2008 generation, designed for use on standard engineering PCs running compatible Windows operating systems.
WinCC flexible 2008 provides a comprehensive development environment for creating HMI visualization projects, including screen editors, tag management, alarm logging, recipe management, and trend displays. The software supports a wide range of SIMATIC HMI target devices, from Micro Panels and Mobile Panels to Multi Panels and PC-based systems. It offers integrated communication configuration for PROFIBUS, PROFINET, MPI, and other industrial protocols, and includes simulation tools that allow project testing without physical hardware.
This software is primarily used by automation engineers and system integrators configuring SIMATIC HMI panels in manufacturing, process automation, and machine building applications. Industries such as automotive, food and beverage, chemical processing, and packaging rely on WinCC flexible 2008 to develop operator interfaces for production lines, process control stations, and machine HMI systems. The software is suited for projects requiring structured visualization development with version-controlled project files compatible with SIMATIC HMI hardware generations up to and including the TP, OP, MP, and Mobile Panel series.
Technical Specifications
| Software Product | WinCC flexible 2008 |
|---|---|
| License Type | Engineering software license |
| Series/Product Family | SIMATIC WinCC flexible |
| Compatible HMI Devices | SIMATIC Micro Panels, TP/OP/MP Panels, Mobile Panels, Multi Panels |
| Communication Protocols | PROFIBUS, PROFINET, MPI, Ethernet |
| Operating System (Host PC) | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Simulation | Integrated HMI runtime simulator |
| Project Functions | Screen editor, tag management, alarm logging, recipe management, trend display |
| Integration | SIMATIC Manager, STEP 7 compatible |
| Delivery Format | Software package with license key |
| Certifications | CE |
Common Error Codes and System Events
- Event ID: 1000
- Application error during WinCC flexible startup, typically caused by corrupted installation files or missing runtime components.
Repair or reinstall the WinCC flexible 2008 software. Ensure all prerequisite components such as .NET Framework and SQL Server are correctly installed. - Event ID: 1001
- License not found or license key invalid. The software cannot verify a valid engineering license.
Check that the hardware dongle (SIMATIC Automation License Manager) is connected and recognized. Reactivate the license using the Automation License Manager tool. - Compiler Error
- Project compilation failed due to inconsistent tag references, missing screen objects, or unsupported functions for the target device.
Review the compiler output log, resolve all listed inconsistencies, and verify that all used functions are supported by the selected target HMI device type. - Communication Error
- No connection established between the engineering PC and the target HMI panel during download or upload.
Verify the communication interface settings (MPI address, PROFIBUS baud rate, or Ethernet IP address). Check cable connections and ensure the correct PC adapter is selected in the transfer settings. - Transfer Error
- Project transfer to the HMI panel was interrupted or failed, possibly due to incompatible firmware version on the target device.
Update the HMI panel firmware to a version compatible with WinCC flexible 2008. Retry the transfer and ensure no other application is occupying the communication port. - Simulation Fault
- The integrated simulator failed to start or crashed during project simulation, often due to insufficient PC resources or conflicting software.
Close unnecessary applications to free system resources. Ensure the PC meets minimum hardware requirements and that no conflicting HMI runtime software is installed. - Database Error
- Internal project database corruption detected, which may prevent opening or saving the WinCC flexible project file.
Use the WinCC flexible project repair function if available. Restore from a recent backup copy of the project file. Reinstall the software if the issue persists.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports a wide range of SIMATIC HMI devices including Micro Panels (KP, TP series), Operator Panels (OP series), Multi Panels (MP series), Mobile Panels, and PC-based WinCC flexible Runtime systems. Compatibility depends on the specific edition of WinCC flexible 2008 installed.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 was designed for Windows XP, Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10, and installation on Windows 10 may result in compatibility issues or software instability.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. However, some functions and screen objects may require manual rework after migration due to differences between the two platforms.
Does this software require a hardware dongle or license key?
Yes, WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager (ALM). The license may be stored on a USB dongle or transferred to the engineering PC's hard drive.
Can WinCC flexible 2008 communicate with SIMATIC S7-300 and S7-400 PLCs?
Yes, WinCC flexible 2008 supports direct communication with SIMATIC S7-300 and S7-400 PLCs via MPI, PROFIBUS DP, and Ethernet (PROFINET/TCP/IP), making it fully compatible with these controller families.
Troubleshooting
WinCC flexible 2008 fails to install or installation stops midway
Check the Windows Event Viewer for installation errors. Verify that all prerequisites such as Microsoft .NET Framework, MSXML, and SQL Server components are present and at the correct version.
Install all required prerequisite software listed in the WinCC flexible 2008 readme file before attempting installation. Run the installer as Administrator and disable antivirus software temporarily during installation.
License not recognized after installation
Open the Siemens Automation License Manager and check whether the license for WinCC flexible 2008 is listed and shown as valid. Verify that the USB dongle is detected by the operating system.
Reconnect the USB license dongle and refresh the Automation License Manager. If the license is stored on the hard drive, use the ALM to verify and repair the license. Contact Siemens license support if the license remains invalid.
Project cannot be transferred to the HMI panel
Check the transfer settings in WinCC flexible for the correct interface type (MPI, PROFIBUS, or Ethernet) and address parameters. Verify physical cable connections and that the HMI panel is in transfer mode.
Correct the interface and address settings to match the physical connection. Ensure the HMI panel firmware version is compatible with the project. Use the PC Adapter USB or appropriate communication hardware for MPI/PROFIBUS connections.
Compiled project reports errors for unsupported functions
Review the compiler error list to identify which functions or objects are flagged. Cross-reference these with the supported feature set for the selected target HMI device in the WinCC flexible documentation.
Replace unsupported functions with compatible alternatives for the target device, or change the target device type in the project settings if a more capable panel is being used.
WinCC flexible crashes or freezes when opening large projects
Monitor PC CPU and RAM usage during project loading. Large projects with many screens, tags, or scripts can exceed the memory capacity of 32-bit systems.
Ensure the engineering PC has at least 2 GB RAM and meets the recommended hardware specifications. Reduce project complexity where possible, and ensure no other memory-intensive applications are running simultaneously.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page



