• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-2BM18-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6371-2BM18-0AX0 WinCC flexible 2008

    € 1.660,32

    Reset
    Clear
    SKU: 6AV6371-2BM18-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-2BM18-0AX0 is a software license for WinCC flexible 2008, part of Siemens' SIMATIC HMI software portfolio. This engineering software package is used to configure, program, and commission SIMATIC HMI panels and operator interface devices within the TIA (Totally Integrated Automation) ecosystem. It provides a comprehensive development environment for creating visualization projects across a wide range of Siemens HMI hardware targets.

    WinCC flexible 2008 offers a tag-based licensing model and supports configuration of the full range of SIMATIC HMI devices, from Micro Panels through to Multi Panels and PC-based systems. The software includes libraries of pre-built faceplates, dynamic wizards, and integrated simulation tools that allow offline testing of HMI projects without physical hardware. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and integrates directly with STEP 7 for consistent data management and symbol sharing across PLC and HMI projects.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering environments. It is particularly suited to OEMs and system integrators who need to develop standardized HMI solutions across multiple machine types. The software supports multilingual project configuration, making it appropriate for international deployments in industries such as automotive, food and beverage, pharmaceuticals, and water treatment.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user license
    Compatible HMI Devices SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels
    Communication Interfaces Supported PROFIBUS, PROFINET, MPI, Ethernet
    PLC Integration SIMATIC STEP 7 (S7-300, S7-400, S7-200)
    Operating System Windows XP, Windows Vista, Windows 7
    Simulation Integrated offline project simulation
    Language Support Multilingual project configuration
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000000
    General runtime error during project execution on the HMI panel
    Check project configuration for invalid tag references or communication settings. Recompile and re-download the project to the target device.
    Event ID: 1000003
    Communication connection to PLC lost or unavailable
    Verify network cabling and interface settings. Check PLC is powered and in RUN mode. Confirm correct IP address or MPI/PROFIBUS address is configured in the project.
    Event ID: 1000010
    Tag read/write error — tag value could not be read from or written to the PLC
    Check that the PLC address referenced by the tag exists and is accessible. Verify data type consistency between HMI tag and PLC variable.
    Event ID: 1000020
    License not found or license validation failed during project compilation
    Verify that the WinCC flexible 2008 license is correctly installed using the Automation License Manager. Reinstall the license if necessary.
    Event ID: 1000050
    Project transfer to HMI device failed
    Check the transfer connection type (USB, Ethernet, or MPI). Ensure the HMI device is in transfer mode and that the correct interface is selected in the transfer settings.
    Event ID: 1000100
    Inconsistent project data detected — project may have been modified by a different software version
    Open and recompile the project in WinCC flexible 2008. Ensure all team members use the same software version when working on shared projects.
    Event ID: 1000200
    Alarm log or data log storage limit exceeded on target HMI device
    Increase the allocated storage size for logs in the project settings, or configure automatic log archiving to an external storage medium or server.

    Frequently Asked Questions

    Which SIMATIC HMI devices can be configured with WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI hardware including Micro Panels (TP 170 Micro, TP 177 Micro), Mobile Panels, Operator Panels (OP 77, OP 177), and Multi Panels (MP 277, MP 377). It does not support the newer Comfort Panels, which require TIA Portal with WinCC.

    Is WinCC flexible 2008 compatible with STEP 7?

    Yes, WinCC flexible 2008 integrates directly with SIMATIC STEP 7, allowing shared symbol tables and consistent tag management between PLC and HMI projects. This integration reduces configuration effort and minimizes errors from duplicate data entry.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. However, manual rework is typically required after migration due to differences in functionality and device support between the two platforms.

    What operating systems are supported for installing WinCC flexible 2008?

    WinCC flexible 2008 is supported on Windows XP (SP3), Windows Vista, and Windows 7 (32-bit and 64-bit). It is not officially supported on Windows 10 or later operating systems.

    Does WinCC flexible 2008 include a simulation function?

    Yes, the software includes an integrated simulator that allows HMI projects to be tested offline on the engineering PC without requiring a physical HMI panel or PLC connection.

    Troubleshooting

    Software fails to install or reports a license error after installation

    Check the Automation License Manager (ALM) to verify whether the license key has been correctly transferred and is visible. Confirm the license matches the installed software edition (e.g., Standard, Advanced).

    Use the Automation License Manager to transfer or repair the license. If the license is stored on a USB dongle, ensure the dongle is connected before launching the software. Reinstall the license from the original media if it is corrupted.

    Project compilation fails with tag limit exceeded error

    Review the total number of configured tags in the project. Each WinCC flexible 2008 license edition has a maximum tag count (e.g., 128 tags for Micro edition, 2048 for Standard).

    Reduce the number of configured tags or upgrade to a higher license edition that supports a greater tag count. Consolidate tags where possible by using array or structured data types.

    Transfer to HMI device fails with connection timeout

    Verify the selected transfer channel (USB, Ethernet, or MPI/PROFIBUS) in the transfer dialog. Check that the HMI device is set to transfer mode and that firewall software on the PC is not blocking the connection.

    Disable Windows Firewall temporarily during transfer, or add WinCC flexible as a firewall exception. For Ethernet transfers, confirm the PC and HMI are on the same subnet. For MPI transfers, verify the PC adapter settings in the Set PG/PC Interface dialog.

    Runtime project on HMI panel shows communication errors for all tags

    Check the communication driver settings in the project, including the PLC address, interface type, and baud rate. Verify physical cabling between the HMI and PLC.

    Correct the communication parameters in WinCC flexible 2008 and retransfer the project. Replace or reseat communication cables. Confirm the PLC is powered and in RUN mode with the correct network address.

    WinCC flexible 2008 crashes or becomes unstable on the engineering PC

    Check the PC operating system version and installed service packs for compatibility. Review the Windows Event Viewer for application error logs related to WinCC flexible processes.

    Ensure the PC meets the minimum hardware requirements and runs a supported OS (Windows XP SP3, Vista, or Windows 7). Install all recommended Siemens patches and service packs for WinCC flexible 2008. Disable unnecessary background applications that may conflict with the software.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart