• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1HQ10-0AX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6371-1HQ10-0AX0 SIMATIC WinCC

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6371-1HQ10-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1HQ10-0AX0 is a software license for SIMATIC WinCC, Siemens' professional SCADA and HMI runtime software platform. This part number corresponds to a WinCC Runtime license within the SIMATIC WinCC V7 family, designed to provide supervisory control and data acquisition capabilities for industrial process visualization on standard PC-based hardware. It enables operators to monitor, control, and log process data from connected automation systems.

    SIMATIC WinCC offers a comprehensive set of features including process visualization, alarm management, trend displays, and historical data archiving. The software supports a wide range of communication interfaces including PROFIBUS, PROFINET, MPI, and OPC UA, enabling seamless integration with Siemens S7 PLCs and third-party controllers. It provides a scalable architecture supporting single-user and multi-user configurations, with robust scripting capabilities via VBScript and C-Script for custom automation logic and reporting.

    SIMATIC WinCC is widely deployed in process industries such as chemical, pharmaceutical, water treatment, and power generation, as well as in discrete manufacturing environments including automotive and machine building. Its compatibility with the broader Siemens TIA Portal ecosystem and support for redundant server configurations makes it suitable for applications requiring high availability and continuous process monitoring. The software is also used in infrastructure projects such as building automation and transportation systems.

    Technical Specifications

    Software Platform SIMATIC WinCC V7
    License Type Runtime License
    Operating System Compatibility Windows Server / Windows 10 (64-bit)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC UA, OPC DA
    PLC Compatibility Siemens S7-300, S7-400, S7-1200, S7-1500, ET 200
    Scripting Support VBScript, C-Script
    Archiving Process value archiving, alarm archiving
    Redundancy Support Yes (server redundancy configurable)
    Multi-User Support Yes
    TIA Portal Integration Compatible via WinCC TIA Portal Engineering
    Certifications CE, UL
    Series/Product Family SIMATIC WinCC V7

    Common Error Codes and System Events

    Event ID: 1000000
    WinCC Runtime startup error — the runtime could not be started due to a configuration or licensing issue.
    Check that a valid license is installed using the Siemens License Manager (SIMATIC Automation License Manager). Verify the project configuration for errors before restarting runtime.
    Event ID: 1001
    Communication error to PLC — WinCC cannot establish or maintain a connection to the configured PLC channel.
    Verify network connectivity, check channel driver configuration, confirm PLC IP address or MPI/PROFIBUS address settings, and ensure the PLC is in RUN mode.
    Event ID: 2000
    Archive database error — the process value or alarm archive database is unavailable or corrupted.
    Check SQL Server service status, verify database file integrity, and if necessary restore the archive from a backup or reinitialize the archive.
    Event ID: 10000
    License not found — no valid WinCC Runtime license detected on this system.
    Install the correct WinCC Runtime license using the SIMATIC Automation License Manager. Ensure the license matches the configured power tag count.
    Event ID: 3000
    Tag logging overflow — the process value archive buffer has overflowed due to high data volume or slow storage.
    Reduce the logging cycle time, optimize the number of archived tags, or upgrade storage hardware to improve write performance.
    Event ID: 4000
    Alarm logging error — alarm events cannot be written to the alarm archive.
    Check the alarm logging configuration, verify SQL Server connectivity, and ensure sufficient disk space is available for the alarm database.
    Event ID: 5000
    Script runtime error — a VBScript or C-Script action has encountered an unhandled exception during execution.
    Review the script code for syntax or logic errors, check the WinCC diagnostics log for the specific script name and line number, and correct the script accordingly.

    Frequently Asked Questions

    What is the power tag limit for the 6AV6371-1HQ10-0AX0 WinCC Runtime license?

    The 6AV6371-1HQ10-0AX0 corresponds to a specific WinCC Runtime power tag count tier. The exact tag count should be verified against the Siemens order documentation, as WinCC Runtime licenses are available in increments such as 128, 512, 2048, 8192, and 65536 power tags.

    Is this WinCC license compatible with TIA Portal?

    SIMATIC WinCC V7 is a standalone SCADA platform and is separate from WinCC in TIA Portal (WinCC Basic/Comfort/Advanced/Professional). Integration with TIA Portal projects requires the appropriate TIA Portal WinCC license variant.

    What database system does SIMATIC WinCC use for archiving?

    SIMATIC WinCC uses Microsoft SQL Server as its backend database for process value archiving and alarm logging. SQL Server is typically installed automatically as part of the WinCC installation process.

    Can WinCC 6AV6371-1HQ10-0AX0 be used in a redundant server configuration?

    Yes, WinCC V7 supports redundant server configurations where a standby server takes over automatically in the event of a primary server failure, provided the appropriate redundancy license is also installed.

    What operating systems are supported by SIMATIC WinCC V7?

    SIMATIC WinCC V7 supports 64-bit versions of Windows 10 and Windows Server 2016/2019. Older versions may also support Windows 7, but Siemens recommends using currently supported operating systems for security and compatibility reasons.

    Troubleshooting

    WinCC Runtime fails to start and displays a licensing error

    Open the SIMATIC Automation License Manager and check whether a valid WinCC Runtime license is present and not expired or transferred to another system.

    Install or transfer the correct WinCC Runtime license to the target PC using the Automation License Manager. Ensure the license tier matches or exceeds the number of configured power tags in the project.

    No communication between WinCC and the connected PLC

    Check the WinCC channel diagnostics in the Tag Management editor. Verify the network connection, PLC address settings, and that the correct channel driver is installed and configured.

    Correct the channel configuration (IP address, rack/slot, or MPI address), restart the channel driver, and confirm the PLC is reachable via a ping or STEP 7/TIA Portal online connection test.

    Process values are not being archived or trend displays show no data

    Check the SQL Server service status in Windows Services. Verify that the WinCC archive tags are correctly configured with valid logging cycles and that the archive database is not full or corrupted.

    Restart the SQL Server service if stopped, clear old archive data if disk space is exhausted, and reinitialize the archive database if corruption is detected. Verify tag logging configuration in WinCC Explorer.

    WinCC project opens but screens display incorrectly or graphics are missing

    Check the WinCC project for missing picture files or broken object references. Verify that all required WinCC options and add-ons are installed on the runtime PC.

    Reinstall missing WinCC options, restore missing picture files from a project backup, and recompile the project in the WinCC configuration editor before restarting runtime.

    Alarm messages are not appearing in the alarm control at runtime

    Verify that the WinCC Alarm Logging editor has active alarm blocks configured and that the runtime alarm control is connected to the correct alarm log. Check that the SQL Server alarm database is accessible.

    Reconfigure the alarm control object to reference the correct alarm log, ensure the Alarm Logging runtime component is active, and verify SQL Server connectivity and database integrity.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart