• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1GC08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6371-1GC08-0AX0 WinCC flexible 2008

    € 1.066,86

    Reset
    Clear
    SKU: 6AV6371-1GC08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1GC08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of operator panels.

    WinCC flexible 2008 offers a scalable engineering environment supporting project creation for the full range of Siemens SIMATIC HMI panels, from Micro Panels up to Multi Panels and PC-based runtime systems. The software includes features such as faceplates, scripts (VBScript), alarm management, trend displays, recipe management, and user administration. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and WinAC controllers. The software runs on standard Windows operating systems and integrates with the SIMATIC engineering environment.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for industries such as automotive, food and beverage, chemical processing, and packaging, where reliable HMI visualization and operator control are required. The software's scalability makes it applicable to both small standalone machines and large distributed production systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single-user license
    Compatible HMI Panels SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400, WinAC
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Series/Product Family SIMATIC WinCC flexible
    Alarm Management Supported
    Recipe Management Supported
    User Administration Supported
    Trend Display Supported

    Common Error Codes and System Events

    Event ID: 1000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target system.
    Check that the correct runtime version is installed and that the license key is valid. Reinstall the runtime if necessary.
    Event ID: 1001
    License not found — No valid license detected for WinCC flexible engineering or runtime.
    Verify the license dongle (USB) is connected or the software license is correctly activated using the Siemens Automation License Manager (ALM).
    Event ID: 1010
    Communication error — The HMI project cannot establish a connection to the configured PLC or controller.
    Check the communication cable and interface settings. Verify the PLC address, network parameters, and that the PLC is powered and running.
    Event ID: 1020
    Project transfer error — Transfer of the HMI project to the target panel failed.
    Confirm the transfer settings (IP address or MPI address) match the target device. Ensure the panel is in transfer mode and the network connection is active.
    Event ID: 1030
    Tag read/write error — A configured tag cannot be read from or written to the connected controller.
    Check the tag address configuration in the project. Verify the PLC data block or memory area exists and the communication connection is active.
    Event ID: 1040
    Compilation error — The HMI project contains configuration errors and cannot be compiled successfully.
    Review the error list in the WinCC flexible engineering software. Correct all reported configuration inconsistencies before recompiling.
    Event ID: 1050
    Alarm log overflow — The alarm buffer on the HMI runtime has reached its maximum capacity.
    Acknowledge and clear pending alarms. Increase the alarm buffer size in the project settings or archive alarms to an external storage location.
    Event ID: 1060
    Recipe data error — A recipe record could not be read or written correctly.
    Check the recipe configuration and verify that the associated PLC tags are correctly mapped and accessible.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (TP 170 Micro, OP 73 Micro), Mobile Panels, Operator Panels (OP 77, TP 177, OP 177), Multi Panels (MP 277, MP 377), and PC-based runtime systems.

    Is WinCC flexible 2008 compatible with TIA Portal?

    WinCC flexible 2008 is not natively part of the TIA Portal environment. Siemens provides a migration tool to convert WinCC flexible projects to WinCC in TIA Portal, but the two engineering environments are separate.

    What operating systems are supported for running WinCC flexible 2008?

    WinCC flexible 2008 is supported on Windows XP Professional, Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10 or later without compatibility measures.

    Does WinCC flexible 2008 require a hardware dongle for licensing?

    Licensing is managed through the Siemens Automation License Manager (ALM). Depending on the license type, it may use a USB dongle or a software-based license tied to the PC.

    Can WinCC flexible 2008 communicate with S7-1200 or S7-1500 PLCs?

    WinCC flexible 2008 has limited or no native support for S7-1200 and S7-1500 PLCs. For these controllers, Siemens recommends using WinCC in TIA Portal instead.

    Troubleshooting

    WinCC flexible 2008 fails to start or crashes on launch

    Check Windows Event Viewer for application errors. Verify that the correct version of Microsoft .NET Framework and other prerequisites are installed. Confirm the license is valid via the Automation License Manager.

    Reinstall the required prerequisites (e.g., .NET Framework, SIMATIC communication drivers). Reactivate or reconnect the license dongle. If the issue persists, perform a clean reinstallation of WinCC flexible 2008.

    HMI project cannot be transferred to the target panel

    Verify the transfer channel settings in the project (IP address, MPI address, or USB). Confirm the panel is switched to transfer mode. Check that the PC and panel are on the same network or correctly connected via the appropriate cable.

    Correct the transfer settings to match the target panel's configured address. Use a direct Ethernet or USB connection if network transfer is unreliable. Ensure any firewall software on the PC is not blocking the transfer.

    Runtime does not display current PLC values — tags show dashes or zero

    Check the communication status indicator in the WinCC flexible Runtime. Verify the PLC is running and the communication parameters (IP address, rack, slot) in the project match the actual PLC configuration.

    Correct the connection parameters in the WinCC flexible project and retransfer to the panel. Ensure the SIMATIC communication drivers are correctly installed on the engineering PC or runtime system.

    Compilation of the project fails with multiple errors

    Open the output window in WinCC flexible engineering software and review the error list. Common causes include missing tag connections, invalid screen references, or unsupported functions for the selected target panel type.

    Resolve each reported error systematically. Verify that the selected target device in the project settings matches the actual hardware. Remove or correct any unsupported objects or tag references.

    Alarm messages are not displayed on the HMI runtime

    Check the alarm configuration in the project, including trigger tags, alarm classes, and display settings. Verify that the associated PLC tags are correctly mapped and that the communication connection is active.

    Correct the alarm trigger tag addresses and ensure the alarm view or alarm window object is correctly placed on the relevant screens. Retransfer the updated project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart