• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1CB08-0AX0 WinCC Runtime
    Awaiting product image

    Siemens 6AV6371-1CB08-0AX0 WinCC Runtime

    € 718,12

    Reset
    Clear
    SKU: 6AV6371-1CB08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1CB08-0AX0 is a WinCC Runtime software license belonging to Siemens' SIMATIC WinCC product family. WinCC (Windows Control Center) is a supervisory control and data acquisition (SCADA) and human-machine interface (HMI) software platform designed for process visualization and operator control on PC-based systems. This specific part number corresponds to a WinCC Runtime license with a defined number of power tags, enabling runtime operation of configured WinCC projects on industrial PC hardware.

    The WinCC Runtime software provides a comprehensive set of visualization and control capabilities, including process value archiving, alarm and event management, trend displays, and report generation. It supports a wide range of communication interfaces and drivers, enabling connectivity to SIMATIC S7 PLCs via PROFIBUS, PROFINET, and MPI, as well as third-party systems through OPC DA and OPC UA. The runtime environment operates on Windows-based industrial PCs and panel PCs, and supports redundant server configurations for high-availability applications. Tag-based licensing defines the number of simultaneously active process variables the runtime can handle.

    WinCC Runtime is widely deployed in manufacturing, process industries, energy management, water treatment, and building automation applications where centralized process visualization and data logging are required. It is particularly suited for applications demanding detailed historical data archiving, multi-client server architectures, and integration with MES or ERP systems via open interfaces. The software is commonly installed on Siemens SIMATIC IPC industrial computers or standard Windows PCs meeting the specified hardware requirements.

    Technical Specifications

    Software Type SCADA / HMI Runtime Software
    Product Family SIMATIC WinCC
    License Type Runtime License
    Operating System Compatibility Windows 10 / Windows Server (64-bit)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500, and third-party via OPC
    Archiving Process value archiving, alarm and event logging
    Redundancy Support Server redundancy supported
    Certifications CE
    Installation Medium Software license (electronic or physical media)
    Series WinCC V7.x

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure. The runtime process could not be initialized correctly.
    Check Windows Event Viewer for detailed error messages. Verify that the WinCC license is valid and correctly installed using the Siemens License Manager (Automation License Manager).
    Event ID: 1000001
    Tag communication error. One or more configured tags cannot be read from the connected PLC or data source.
    Verify the communication channel configuration in WinCC Explorer. Check network connectivity to the PLC and confirm the correct IP address, rack, and slot settings.
    Event ID: 1000002
    License not found or invalid. WinCC Runtime cannot find a valid license for the configured number of power tags.
    Open the Automation License Manager and verify that the correct WinCC Runtime license is present and not expired. Transfer a valid license from the license storage medium if required.
    Event ID: 1000003
    Archive database error. The WinCC process data or alarm archive database cannot be accessed or is corrupted.
    Check the SQL Server service status. Run the WinCC database consistency check tool and restore from backup if the database is found to be corrupted.
    Event ID: 1000004
    OPC server connection failure. WinCC cannot establish a connection to the configured OPC DA or OPC UA server.
    Verify that the OPC server is running and accessible on the network. Check DCOM settings for OPC DA connections or endpoint configuration for OPC UA connections.
    Event ID: 1000005
    Redundancy switchover event. The WinCC redundant server has switched from the primary to the standby server.
    Investigate the cause of the primary server failure. Check network connectivity, hardware status, and Windows Event Viewer logs on the primary server before attempting to restore it to active status.
    Event ID: 1000006
    User administration error. A user login attempt failed or user rights configuration is inconsistent.
    Verify user account settings in the WinCC User Administrator. Ensure the Windows user account used for WinCC Runtime has the required permissions.

    Frequently Asked Questions

    What is the power tag capacity of the 6AV6371-1CB08-0AX0 WinCC Runtime license?

    The 6AV6371-1CB08-0AX0 corresponds to a WinCC Runtime license for 128,000 power tags, allowing up to 128,000 simultaneously active process variables in the runtime environment.

    Is the WinCC Runtime software compatible with SIMATIC S7-1500 PLCs?

    Yes, WinCC Runtime supports communication with SIMATIC S7-1500 PLCs via PROFINET using the SIMATIC NET communication drivers included with WinCC.

    Can WinCC Runtime be used in a redundant server configuration?

    Yes, WinCC Runtime supports server redundancy, where a standby server automatically takes over if the primary server fails, ensuring continuous process visualization and data archiving.

    What operating systems are supported by WinCC Runtime V7?

    WinCC Runtime V7 is supported on 64-bit versions of Windows 10 and Windows Server editions as specified in the Siemens compatibility list for the respective WinCC version.

    Does WinCC Runtime support OPC UA communication?

    Yes, WinCC Runtime includes an OPC UA server and client interface, enabling standardized data exchange with third-party systems, MES, and ERP platforms.

    Troubleshooting

    WinCC Runtime fails to start after installation

    Check the Automation License Manager to confirm a valid license is installed. Review the Windows Event Viewer Application and System logs for error messages related to WinCC or SQL Server services.

    Install or transfer the correct WinCC Runtime license using the Automation License Manager. Ensure that Microsoft SQL Server, which is required by WinCC, is running and properly configured.

    Process tags show no values or display connection errors in Runtime

    Open WinCC Explorer and check the channel diagnostics for the affected communication channel. Verify network connectivity to the PLC using ping and confirm the PLC address settings match the WinCC channel configuration.

    Correct the IP address, rack, or slot configuration in the WinCC channel settings. Restore network connectivity between the WinCC PC and the PLC, and restart the WinCC Runtime if necessary.

    Alarm archiving stops recording new alarms

    Check the status of the Microsoft SQL Server service on the WinCC server. Verify available disk space on the drive hosting the WinCC archive database.

    Free up disk space or expand the archive storage allocation. Restart the SQL Server service if it has stopped, and run the WinCC database consistency check to repair any database errors.

    WinCC Runtime client cannot connect to the WinCC server

    Verify that the WinCC server Runtime is active and that the server name or IP address configured on the client is correct. Check Windows Firewall settings on the server for blocked WinCC ports.

    Configure Windows Firewall to allow WinCC communication ports. Ensure the client PC has the correct WinCC client software version installed and that the server project is published for client access.

    Historical trend displays show no data or gaps in archived values

    Check the WinCC Tag Logging configuration to confirm that the relevant tags are assigned to an archive and that the archive cycle is correctly set. Verify that the SQL Server archive database is accessible.

    Correct the Tag Logging configuration and ensure the archive is active. If data gaps exist due to a server outage, check whether the redundant server archived data during the downtime and synchronize the archives.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart