• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7HC1 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7HC1 OP 77B

    € 764,03

    Reset
    Clear
    SKU: 6AV6355-1CA47-7HC1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7HC1 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product line. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a straightforward interface for process visualization and operator control. It is part of the broader SIMATIC HMI Basic Panels generation, intended for use in cost-sensitive yet reliable automation environments.

    The OP 77B features a monochrome STN LCD display and a membrane keypad for operator input, eliminating the need for a touchscreen while maintaining robust usability in industrial environments. It supports the MPI and PROFIBUS DP communication interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers onboard flash memory for project storage. It operates on a 24 V DC supply and is rated to IP65 on the front face, providing protection against dust and water jets.

    The OP 77B is widely deployed in manufacturing, packaging, and process industries where a compact, keypad-operated HMI is preferred over a full touchscreen panel. It is particularly suited for machine builders who require a cost-effective operator interface for straightforward control tasks such as parameter entry, alarm display, and status monitoring. Its compatibility with the established SIMATIC S7 controller family makes it a practical choice for integration into existing Siemens automation architectures.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Size 4.7 inch
    Display Colors Monochrome (blue-mode)
    Input Voltage 24 V DC
    Permissible Voltage Range 19.2 V DC to 28.8 V DC
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Configuration Software WinCC flexible 2005 or higher
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 1000
    System startup completed successfully. The HMI panel has finished its boot sequence and is ready for operation.
    No action required. This is an informational system event confirming normal startup.
    Event ID: 10000
    Connection to PLC lost. The HMI panel cannot establish or has lost communication with the configured controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Check configured station address and baud rate in the HMI project.
    Event ID: 10001
    Connection to PLC established. Communication between the HMI panel and the PLC has been successfully restored or initialized.
    No action required. This is an informational event confirming successful communication.
    Event ID: 20000
    Tag read error. The HMI panel is unable to read a configured process tag from the PLC.
    Verify the tag address exists in the PLC program and that the data block or memory area is accessible. Check for address mismatches between the HMI project and PLC program.
    Event ID: 20001
    Tag write error. The HMI panel is unable to write a value to a configured process tag in the PLC.
    Confirm the target PLC memory area is not write-protected. Verify the tag address and data type match the PLC configuration. Check communication status.
    Event ID: 40000
    Project download in progress or project data error detected on startup.
    Re-download the HMI project using WinCC flexible. Ensure the project was compiled without errors before transfer. Check the transfer cable or PROFIBUS connection used for downloading.
    Event ID: 70010
    Insufficient memory for project data. The panel's flash memory does not have enough space for the loaded project.
    Reduce the project size by removing unused screens, graphics, or recipes. Re-download the optimized project to the panel.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7HC1)?

    The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with S7-1200 in some configurations depending on firmware version.

    What software is used to configure and program the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2005 or later versions. Projects are compiled in WinCC flexible and downloaded to the panel via MPI, PROFIBUS DP, or a PC/PPI cable.

    What is the front panel protection rating of the 6AV6355-1CA47-7HC1?

    The front face of the OP 77B is rated IP65, providing full protection against dust ingress and protection against water jets. The rear of the unit is rated IP20.

    Does the OP 77B support recipe management and alarm logging?

    Yes, the OP 77B supports basic recipe management and alarm/event logging functions as configured within WinCC flexible. Storage capacity is limited by the onboard flash memory.

    What is the supply voltage for the OP 77B?

    The OP 77B operates on a 24 V DC supply with a permissible operating range of 19.2 V DC to 28.8 V DC.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Verify the voltage is within the 19.2 V to 28.8 V DC range. Check for a blown internal fuse.

    Correct the supply voltage if out of range. Replace the internal fuse if blown. If the display backlight has failed, the panel may require backlight or display assembly replacement.

    HMI panel shows 'No connection to PLC' or communication fault on startup

    Check the MPI or PROFIBUS DP cable for physical damage and secure connection at both the panel and PLC ends. Verify the bus termination resistors are correctly placed at both ends of the network. Confirm the station address and baud rate in the HMI project match the PLC settings.

    Replace damaged cables or connectors. Correct the station address and baud rate in the WinCC flexible project and re-download. Ensure only the two physical end nodes have termination resistors enabled.

    Project cannot be downloaded to the panel

    Verify the transfer cable is correctly connected and the panel is in transfer mode. Check that the WinCC flexible project has been compiled without errors. Confirm the communication settings (baud rate, station address) in the transfer dialog match the panel configuration.

    Set the panel to transfer mode via the Start Center menu. Recompile the project in WinCC flexible and retry the download. If using MPI, ensure the PC adapter is correctly configured and recognized by the PC.

    Keypad buttons are unresponsive or intermittently responsive

    Inspect the membrane keypad for physical damage, contamination, or deformation. Check whether the issue is with specific keys or all keys. Test in a clean environment to rule out environmental interference.

    Clean the keypad surface with a dry cloth. If specific keys are permanently unresponsive, the membrane keypad assembly likely requires replacement. Contact a qualified repair technician for keypad replacement.

    Panel repeatedly restarts or crashes during operation

    Check the supply voltage for stability and ripple using an oscilloscope or multimeter. Review the HMI project for memory overload or corrupted project data. Check the operating temperature environment around the panel.

    Stabilize the 24 V DC power supply and ensure it has sufficient current capacity. Re-download a freshly compiled project to the panel. Ensure ambient temperature does not exceed 50 °C and that ventilation around the panel is adequate.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart