Siemens 6AV6355-1CA47-7HB0 OP 77B
€ 2.495,00
The Siemens 6AV6355-1CA47-7HB0 is an operator panel belonging to the OP 77B series, part of the SIMATIC HMI Basic Panels product family manufactured by Siemens. This compact operator panel is designed for machine-level human-machine interface applications, providing a straightforward and reliable interface for monitoring and controlling industrial processes. It features a monochrome display and a membrane keypad for operator input, making it well suited for cost-sensitive automation tasks.
The OP 77B panel is equipped with a 4-inch STN monochrome LCD display with a resolution of 320 x 240 pixels and supports up to 4 gray scales. It communicates via MPI and PROFIBUS DP interfaces, enabling seamless integration with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel operates on a 24 V DC supply, includes 512 KB of user memory, and is rated IP65 on the front face for protection against dust and water ingress. Configuration is performed using WinCC flexible software.
The OP 77B is widely used in manufacturing, packaging, and material handling machinery where a compact and robust operator interface is required. Its compatibility with the SIMATIC S7 controller family makes it a natural fit for existing Siemens automation architectures. The panel is particularly suitable for applications requiring simple process visualization, alarm management, and recipe handling at the machine level.
Technical Specifications
| Display Size | 4 inch |
|---|---|
| Display Type | STN monochrome LCD |
| Display Resolution | 320 x 240 pixels |
| Display Colors | 4 gray scales |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 6 W |
| Communication Interface | MPI, PROFIBUS DP |
| User Memory | 512 KB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible 2005 or higher |
| Certifications | CE, UL, cULus |
Common Error Codes and System Events
- Event ID: 1000
- System startup completed successfully. The HMI device has booted and is ready for operation.
No action required. This is an informational event confirming normal startup. - Event ID: 10000
- Connection to the PLC has been lost or could not be established.
Check MPI or PROFIBUS DP cable connections, verify PLC address settings, and confirm the PLC is powered and running. - Event ID: 10001
- Communication timeout with the configured PLC controller.
Verify baud rate settings on both the HMI and PLC, check cable integrity, and ensure correct station addresses are configured. - Event ID: 20000
- Tag read error. The HMI could not read a configured tag from the PLC.
Check that the tag address exists in the PLC program and that the data type matches the HMI configuration in WinCC flexible. - Event ID: 20001
- Tag write error. The HMI could not write a value to the configured PLC tag.
Verify the PLC tag address, ensure the PLC is not in a protected or read-only mode, and check data type consistency. - Event ID: 40000
- Recipe data error. A recipe transfer to or from the PLC has failed.
Check recipe configuration in WinCC flexible, verify sufficient memory is available, and confirm PLC tag addresses used in the recipe are valid. - Event ID: 70000
- HMI internal memory is full or a memory error has occurred.
Delete unnecessary data, alarms, or recipe records from the HMI. Consider transferring logs to an external storage device if supported.
Frequently Asked Questions
Which PLCs are compatible with the Siemens OP 77B (6AV6355-1CA47-7HB0)?
The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.
What software is used to configure the OP 77B panel?
The OP 77B is configured using Siemens WinCC flexible 2005 or later versions. Projects are transferred to the panel via MPI or a serial PC/PPI cable.
What is the supply voltage for the 6AV6355-1CA47-7HB0?
The panel requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid damage or malfunction.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets.
Can the OP 77B be used with third-party PLCs?
The OP 77B is primarily designed for use with Siemens SIMATIC controllers. Communication with third-party PLCs is not natively supported through standard configuration options in WinCC flexible for this panel.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector on the rear of the panel. Verify polarity and measure actual voltage with a multimeter.
Ensure the supply voltage is within the 24 V DC nominal range. If voltage is correct and display remains blank, the internal power supply or backlight may be faulty and the unit may require repair or replacement.
HMI shows 'No connection to PLC' or communication errors on startup
Inspect the MPI or PROFIBUS DP cable for damage or loose connectors. Verify that the PLC station address and baud rate configured in WinCC flexible match the actual PLC settings.
Correct any address or baud rate mismatches in the WinCC flexible project and retransfer the project to the HMI. Replace damaged cables and ensure proper bus termination resistors are in place at both ends of the PROFIBUS segment.
Touchscreen or keypad inputs are not responding
The OP 77B uses a membrane keypad rather than a touchscreen. Check for physical damage to the keypad overlay or contamination beneath the keys.
Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad assembly will need to be replaced.
Project transfer from PC to HMI fails
Verify the communication cable type and connection between the PC and the HMI. For MPI transfer, ensure the PC adapter (e.g., PC Adapter USB) is correctly installed and the correct COM port is selected in WinCC flexible transfer settings.
Reinstall the PC adapter driver, select the correct interface in WinCC flexible, and retry the transfer. Ensure the HMI is in transfer mode before initiating the download from the PC.
Alarm messages are not displayed or are missing on the HMI
Check the alarm configuration in the WinCC flexible project. Verify that the PLC bit addresses linked to alarm triggers are correctly mapped and that the PLC program is setting the expected bits.
Review and correct alarm tag addresses in WinCC flexible, retransfer the project, and confirm the PLC logic is functioning as expected by monitoring the relevant tags online.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page