• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7ES6 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7ES6 OP 177B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7ES6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7ES6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with keypad-based operation and is part of Siemens' mid-range HMI panel lineup. The OP 177B is engineered for reliable process visualization and operator control in demanding industrial environments.

    The 6AV6355-1CA47-7ES6 features a 5.7-inch STN display and supports communication via MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, enabling integration with SIMATIC S7 and S5 PLCs as well as third-party controllers. The panel includes configurable function keys, a numeric/alphanumeric keypad, and supports WinCC flexible as its configuration software. It operates on a 24 V DC supply and is built to meet industrial protection standards for panel mounting.

    The OP 177B is widely deployed in manufacturing, process automation, and machine building applications where robust operator interaction is required without the complexity of a full touchscreen panel. It is commonly found on packaging machinery, conveyor systems, and production lines where keypad-driven navigation and clear process visualization are preferred. The panel's compatibility with the broad SIMATIC controller ecosystem makes it a practical choice for both new installations and system upgrades.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Resolution 320 x 240 pixels (QVGA)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 10 W
    Communication Interface MPI, PROFIBUS DP, RS-422/RS-485
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Configuration Software WinCC flexible 2008
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC or controller. The connection has been interrupted or cannot be established.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI configuration in WinCC flexible.
    Event ID: 10001
    Connection to the PLC was established but subsequently lost during operation.
    Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify PLC is in RUN mode.
    Event ID: 40000
    Project download error. The configuration project could not be transferred to the panel successfully.
    Ensure the correct communication interface and transfer settings are selected in WinCC flexible. Check USB or MPI/PROFIBUS connection between engineering PC and panel.
    Event ID: 20000
    Tag read/write error. The HMI cannot read from or write to a configured PLC tag or data area.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory area. Confirm the PLC program is running and the addressed area exists.
    Event ID: 50000
    System memory low. The panel's available runtime memory is insufficient for the loaded project.
    Reduce the number of active screens, images, or logged data in the project. Optimize the WinCC flexible project to reduce memory footprint.
    Event ID: 60000
    Internal device error or hardware fault detected on the panel.
    Perform a panel restart. If the error persists, back up the project and perform a factory reset. Contact Siemens technical support or arrange for hardware inspection if the fault recurs.
    Event ID: 30000
    Alarm buffer overflow. The number of pending alarms has exceeded the configured buffer capacity.
    Acknowledge and clear active alarms. Increase the alarm buffer size in the WinCC flexible project configuration if overflow occurs frequently.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6355-1CA47-7ES6)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI or PROFIBUS DP. It also supports communication with SIMATIC S5 controllers and selected third-party PLCs via RS-422/RS-485 using appropriate drivers in WinCC flexible.

    What configuration software is required for this panel?

    The OP 177B is configured using Siemens WinCC flexible 2008 or later compatible versions. Projects are transferred to the panel via MPI, PROFIBUS, or USB connection.

    What is the supply voltage for the 6AV6355-1CA47-7ES6?

    The panel requires a 24 V DC power supply. Ensure the supply is within the permissible tolerance range as specified in the device manual, typically 19.2 V DC to 28.8 V DC.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B is rated IP65, making it suitable for environments where dust and water jets may be present. The rear of the unit is rated IP20.

    Can the OP 177B be used as a replacement for older Siemens OP panels?

    Yes, the OP 177B is designed as a successor to earlier SIMATIC OP panels such as the OP 17 and OP 27. Existing WinCC flexible projects can often be migrated, though hardware cutout dimensions should be verified before installation.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that the voltage is within the 19.2–28.8 V DC range. Inspect the internal fuse if accessible.

    Correct the supply voltage if out of range. Replace the power supply unit if voltage is absent at the source. If supply is correct and display remains blank, the backlight or internal power board may require replacement.

    Panel displays 'No connection to PLC' or communication error at startup

    Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check bus termination is correctly applied at both ends of the network. Confirm the PLC station address and baud rate in WinCC flexible match the PLC configuration.

    Re-seat connectors and replace damaged cables. Correct address and baud rate settings in the WinCC flexible project and re-download. Add or correct bus termination resistors as required.

    Touchscreen or keypad inputs are not responding correctly

    Check whether the panel is in transfer mode, which disables normal operation. Verify no physical damage to the keypad membrane. For function key issues, check key assignments in the WinCC flexible project.

    Exit transfer mode by canceling the transfer dialog. If keypad membrane is damaged, arrange for panel repair or replacement. Correct key assignments in the project and re-download to the panel.

    Project download fails or transfer cannot be initiated

    Confirm the correct transfer channel (MPI, PROFIBUS, or USB) is selected on both the panel and in WinCC flexible. Check that the panel is in transfer mode before initiating download. Verify cable integrity.

    Set the panel to transfer mode via the Start Center menu. Select the matching interface in WinCC flexible transfer settings. Replace the communication cable if transfer still fails after settings are confirmed.

    Panel reboots unexpectedly or freezes during operation

    Check the 24 V DC supply for voltage dips or instability under load. Inspect the operating environment for excessive temperature or vibration. Review the project for memory overload conditions.

    Stabilize the power supply using a dedicated 24 V DC source with adequate current capacity. Ensure ambient temperature is within the 0–50 °C operating range. Optimize the WinCC flexible project to reduce runtime memory usage.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart