• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7ES4 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7ES4 OP 77B

    € 2.995,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7ES4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7ES4 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a straightforward interface for process visualization and control. As part of the SIMATIC HMI Basic Panels family, it is engineered for integration into a wide range of automation environments using Siemens control systems.

    The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels, offering clear readability of process values, alarms, and status messages. It supports communication via MPI and PROFIBUS DP interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel is configured using WinCC flexible software and supports recipe management, alarm logging, and multilingual text display. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.

    The OP 77B is widely used in manufacturing, packaging, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. Its compact form factor and robust construction make it suitable for installation in control cabinet doors and machine panels in industries such as food and beverage, automotive, and general factory automation. The panel's compatibility with the SIMATIC S7 controller family makes it a practical choice for system integrators working within established Siemens automation architectures.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 80 pixels
    Number of Lines 4 lines of text
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Configuration Software WinCC flexible 2008 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 77B and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings in WinCC flexible match the physical configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect the communication cable for damage or loose connectors. Check bus termination and cable shielding. Restart the panel and PLC if the connection is not restored automatically.
    Event ID: 20000
    Configuration data on the panel is missing or corrupted.
    Re-transfer the project from WinCC flexible to the panel. Ensure the correct project version is used and that the transfer completed without errors.
    Event ID: 20001
    Project version mismatch between the loaded configuration and the panel firmware.
    Update the panel firmware to the version compatible with the WinCC flexible project, or recompile and re-transfer the project using the installed WinCC flexible version.
    Event ID: 40000
    Internal panel hardware fault detected.
    Perform a power cycle. If the fault persists, the panel may require repair or replacement of internal components.
    Event ID: 50000
    Alarm buffer overflow. The number of pending alarms exceeds the panel's buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers or increase acknowledgment frequency.
    Event ID: 60000
    Recipe data error. A recipe record could not be read or written correctly.
    Check the recipe configuration in WinCC flexible. Verify that recipe data structures match between the project and the PLC data blocks. Re-transfer the project if necessary.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7ES4)?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. It can also communicate with SIMATIC S7-1200 and S7-1500 controllers in some configurations depending on firmware version.

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are transferred to the panel via the MPI interface or a USB-to-MPI adapter.

    What is the supply voltage for the 6AV6355-1CA47-7ES4?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current, with a maximum power consumption of approximately 4.5 W.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B is rated IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    Can the OP 77B display alarms and messages?

    Yes, the OP 77B supports alarm and message display, including alarm logging and acknowledgment. Alarms are configured within the WinCC flexible project and can be displayed across the panel's text lines.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel's power connector. Measure the voltage under load to confirm it is within the specified range. Inspect the internal fuse if accessible.

    Ensure the power supply output is stable at 24 V DC and can supply adequate current. Replace the power supply if the voltage is out of range. If the supply is correct and the display remains blank, the panel may require internal repair or replacement of the display module.

    Panel shows 'No connection to PLC' or communication error on startup

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC address configured in WinCC flexible matches the physical PLC address setting. Confirm the PLC is powered on and in RUN mode.

    Replace or reseat the communication cable. Correct the PLC address in the WinCC flexible project and re-transfer. Ensure bus termination resistors are enabled only at the physical ends of the bus segment.

    Configuration transfer from WinCC flexible fails or is incomplete

    Check the communication connection between the programming PC and the panel, typically via an MPI adapter. Verify that the WinCC flexible version matches the panel firmware version. Confirm the panel is in transfer mode.

    Place the panel in transfer mode via the Start Center menu. Use a compatible USB-to-MPI or PC-Adapter to establish the connection. Update the panel firmware if there is a version mismatch, then retry the project transfer.

    Touchscreen or function keys not responding correctly

    Check for physical damage to the keypad or front panel. Verify that the project configuration correctly maps function keys to the intended actions. Test individual keys to isolate whether the issue is hardware or software.

    Recalibrate the keypad if a calibration option is available in the panel settings. If specific keys are unresponsive due to hardware failure, the panel front membrane or keypad assembly may need replacement. Re-transfer the project to rule out configuration errors.

    Panel repeatedly restarts or enters an error loop

    Check the supply voltage for instability or voltage drops under load. Review the system event log on the panel for specific event IDs that indicate the cause of the restart. Inspect for overheating due to inadequate ventilation.

    Stabilize the 24 V DC power supply. Ensure the panel is installed within the specified operating temperature range of 0 °C to +50 °C. If a specific event ID is logged, address the corresponding fault condition. If the issue persists, the panel may require professional repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart