• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7EQ3 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7EQ3 OP 177B

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6355-1CA47-7EQ3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7EQ3 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with keypad-based operation and is part of the SIMATIC HMI Comfort and Mobile Panels generation, configured for use with SIMATIC S7 and other compatible controllers. The OP 177B series is engineered for robust industrial environments requiring reliable operator control and visualization.

    The 6AV6355-1CA47-7EQ3 features a 5.7-inch STN display and supports communication via MPI, PROFIBUS DP, and RS-422/485 interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel includes an integrated keypad with function keys, system keys, and numeric/alphanumeric input capability, reducing the need for an external keyboard. It supports WinCC flexible as its configuration software and offers onboard flash memory for project storage, along with a USB interface for data transfer and backup.

    The OP 177B is widely deployed in manufacturing automation, machine tool control, packaging machinery, and process plant environments where a compact, panel-mount HMI with physical keypad operation is preferred over a pure touchscreen solution. Its compatibility with the SIMATIC S7 controller family and support for multiple communication protocols makes it suitable for both new installations and retrofit projects across discrete and process industries.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 12 W
    Communication Interface MPI, PROFIBUS DP, RS-422/485
    Configuration Software WinCC flexible 2008
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC controller. The connection to the configured PLC has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Restart both the HMI and PLC if necessary.
    Event ID: 10001
    Connection to PLC established. This is an informational event indicating successful communication link.
    No action required. Verify that the correct PLC program and HMI project are loaded if unexpected behavior follows.
    Event ID: 40000
    Project download error. The project transfer from the configuration PC to the HMI panel has failed or been interrupted.
    Check USB or serial transfer cable integrity. Ensure WinCC flexible is set to the correct transfer mode and that the panel is in transfer mode. Retry the download.
    Event ID: 50000
    Internal flash memory error. The panel has detected a fault in the internal project memory.
    Perform a complete panel reset and re-download the project. If the error persists, the internal flash memory may require replacement or the unit may need servicing.
    Event ID: 20000
    Tag read/write error. The HMI panel is unable to read from or write to a configured PLC tag or data block.
    Verify the PLC data block and tag addresses in the WinCC flexible project match the actual PLC program. Check PLC program is running and not in STOP mode.
    Event ID: 70010
    Operating system error or runtime fault detected on the HMI panel.
    Perform a panel restart. If the fault recurs, reload the operating system using the ProSave tool via USB and re-download the project.
    Event ID: 60000
    Power supply undervoltage detected. The 24 V DC supply to the panel has dropped below the minimum operating threshold.
    Measure the supply voltage at the panel power connector. Ensure the power supply unit is rated for the panel load and that cable runs are not causing excessive voltage drop.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6355-1CA47-7EQ3)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with a range of third-party controllers via RS-422/485 using appropriate drivers in WinCC flexible.

    What software is required to configure and program this HMI panel?

    The OP 177B is configured using Siemens WinCC flexible 2008 or later compatible versions. Projects are transferred to the panel via USB or serial interface using the ProSave utility or directly from WinCC flexible.

    What is the supply voltage requirement for the 6AV6355-1CA47-7EQ3?

    The panel requires a 24 V DC power supply with a maximum power consumption of approximately 12 W. The supply must be a regulated SELV (Safety Extra Low Voltage) source.

    Does the OP 177B support touchscreen input?

    No, the OP 177B is a keypad-operated panel and does not feature a touchscreen. Operator input is performed via the integrated function keys, system keys, and alphanumeric keypad.

    What is the front panel protection rating of this unit?

    The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for correct polarity. Inspect the internal fuse if accessible.

    Ensure the power supply is providing a stable 24 V DC within the specified tolerance. Replace the supply or correct wiring if voltage is absent or out of range. If voltage is correct and display remains blank, the backlight or internal power board may require replacement.

    HMI panel shows persistent communication error with PLC

    Check the MPI or PROFIBUS DP cable for continuity and correct termination at both ends of the network. Verify the PLC node address and HMI configured address do not conflict. Confirm the PLC is in RUN mode.

    Replace or reseat the communication cable. Correct address settings in the WinCC flexible project and re-download. Ensure bus termination resistors are enabled only at the physical ends of the network segment.

    Project transfer from PC to panel fails

    Confirm the panel is set to Transfer mode (accessible via the Start Center or Control Panel on the device). Check the USB cable or serial cable connection between the PC and panel.

    Restart the panel in Transfer mode and retry the download from WinCC flexible or ProSave. Try a different USB cable or port. Ensure the correct communication interface is selected in the transfer settings.

    Touchkeys or function keys not responding correctly

    Inspect the keypad membrane for physical damage or contamination. Check whether the issue is with specific keys or all keys, which helps distinguish between a membrane fault and a controller board fault.

    Clean the keypad area with a dry cloth. If individual keys are unresponsive due to membrane wear, the keypad membrane assembly should be replaced. If all keys are unresponsive, inspect the internal ribbon cable connection between the keypad and the main board.

    Panel repeatedly restarts or enters an error loop after project load

    Check the WinCC flexible project for configuration errors such as invalid tag addresses or unsupported functions for this panel type. Verify the operating system version on the panel is compatible with the project.

    Update the panel operating system to the version recommended for the WinCC flexible project using ProSave. Recompile and re-download the project after correcting any configuration warnings or errors reported by WinCC flexible.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart