Siemens 6AV6355-1CA47-7EP2 OP 77B
€ 764,03
The Siemens 6AV6355-1CA47-7EP2 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a text-based display for process visualization and operator control. It is a member of the Micro Panel line, intended for straightforward monitoring and control tasks in automation environments.
The OP 77B features a 4-line STN LCD text display capable of showing alphanumeric characters, supporting operator input via a membrane keypad with function keys. It communicates via the MPI/PROFIBUS DP interface, enabling direct connection to SIMATIC S7 PLCs without additional hardware. The unit operates on 24 V DC supply voltage and is configured using Siemens WinCC flexible software, supporting recipe management, alarm logging, and multilingual text display.
The OP 77B is widely deployed in manufacturing, packaging, and process automation industries where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and panel-mount design make it suitable for integration into control cabinet doors and machine enclosures. It is commonly used with SIMATIC S7-200, S7-300, and S7-400 PLC families in discrete and continuous production environments.
Technical Specifications
| Display Type | STN LCD, text-based |
|---|---|
| Display Lines | 4 lines |
| Characters per Line | 20 characters |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI / PROFIBUS DP |
| Configuration Software | WinCC flexible |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes & System Events
- Event ID: 10000
- No connection to PLC or communication partner not reachable
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the configured station address in WinCC flexible. - Event ID: 10001
- Communication timeout with the configured PLC
Check network cable integrity, verify baud rate settings, and confirm the PLC is in RUN mode and responding on the bus. - Event ID: 20000
- Project download failed or project data corrupted
Re-download the project from WinCC flexible to the panel. Ensure the correct panel type and firmware version are selected in the project settings. - Event ID: 40000
- Tag read/write error — variable address not accessible
Verify the tag address configured in WinCC flexible matches the actual PLC data block or memory address. Check PLC program for address conflicts. - Event ID: 50000
- Alarm buffer overflow — too many pending alarms
Acknowledge and clear active alarms on the panel. Review alarm configuration in WinCC flexible to reduce simultaneous alarm triggers. - Event ID: 70000
- Internal device error or firmware fault detected
Perform a power cycle on the panel. If the error persists, perform a factory reset and re-download the project. Contact Siemens support if the fault recurs. - Event ID: 60000
- Recipe data error — recipe record cannot be read or written
Check recipe configuration in WinCC flexible. Verify that the recipe data record addresses are valid and accessible in the connected PLC.
Frequently Asked Questions
Which PLCs are compatible with the Siemens OP 77B (6AV6355-1CA47-7EP2)?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-1200 and S7-1500 controllers depending on firmware version and configuration.
What software is used to configure and program the OP 77B?
The OP 77B is configured using Siemens WinCC flexible software. The project is then downloaded to the panel via the MPI interface or a USB/serial connection.
What is the supply voltage for the 6AV6355-1CA47-7EP2?
The panel operates on 24 V DC supply voltage, which is the standard for SIMATIC HMI operator panels.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.
Can the OP 77B display graphics or only text?
The OP 77B is a text-based operator panel and does not support graphical display. It shows alphanumeric characters across 4 lines of 20 characters each.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify the power supply output is within the specified range and that the connector is firmly seated.
Ensure the 24 V DC supply is stable and correctly wired. If the supply is confirmed good and the display remains blank, the internal power board or display unit may be faulty and require replacement.
Panel shows 'No connection to PLC' message continuously
Verify MPI/PROFIBUS DP cable connections at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment.
Correct any wiring faults, ensure the station address configured in WinCC flexible matches the PLC address, and confirm the baud rate settings are consistent across all devices on the bus.
Project download from WinCC flexible fails
Check the communication cable between the PC and the panel (typically MPI or PC/PPI cable). Verify that the correct COM port and transfer settings are selected in WinCC flexible.
Use a known-good Siemens PC adapter cable, set the panel to transfer mode manually via the Start Center, and re-initiate the download. Ensure the WinCC flexible project is compiled without errors before transfer.
Membrane keypad keys are unresponsive or intermittent
Inspect the keypad membrane for physical damage, contamination, or deformation. Check the internal ribbon cable connection between the keypad and the main board.
Clean the keypad surface with a dry cloth. If the ribbon cable is loose or damaged, reseat or replace it. If the keypad membrane itself is worn, replace the front panel assembly.
Panel reboots unexpectedly during operation
Monitor the 24 V DC supply voltage for dips or instability under load. Check for excessive electrical noise or ground faults in the control cabinet.
Stabilize the power supply and ensure proper grounding of the panel and cabinet. Add filtering capacitors or a dedicated power supply for the HMI if voltage dips are detected.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page