• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7EP0 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7EP0 OP 77B

    € 764,03

    Reset
    Clear
    SKU: 6AV6355-1CA47-7EP0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7EP0 is an operator panel belonging to the OP 77B series, part of the SIMATIC HMI Basic Panels product family manufactured by Siemens. This unit serves as a compact human-machine interface designed for machine-level visualization and operator control tasks. It is intended for use with Siemens SIMATIC S7 PLCs and compatible controllers, providing a straightforward interface for process monitoring and control.

    The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and supports up to 8 function keys for direct operator input. It communicates via MPI and PROFIBUS DP interfaces, enabling seamless integration into existing Siemens automation networks. The panel is configured using WinCC flexible software and supports alarm management, recipe handling, and trend display functions within its compact form factor.

    The OP 77B is widely deployed in manufacturing, packaging, and process automation environments where a cost-effective, reliable operator interface is required at the machine level. Its robust construction and compatibility with the SIMATIC controller ecosystem make it suitable for applications in automotive assembly lines, conveyor systems, and general industrial machinery where space is limited and basic HMI functionality is sufficient.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 80 pixels
    Display Colors Monochrome (black/white)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP 77B
    Configuration Software WinCC flexible 2005 or higher
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC address settings and ensure the PLC is in RUN mode. Confirm baud rate settings match on both devices.
    Event ID: 10001
    Connection to PLC lost during runtime operation.
    Inspect physical cabling for damage or loose connectors. Verify network address configuration in WinCC flexible project. Restart the panel and PLC if connection is not restored automatically.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel successfully.
    Check the PC-to-panel transfer cable and communication settings. Ensure WinCC flexible version is compatible with the panel firmware. Retry the download after restarting both the PC and the panel.
    Event ID: 40000
    System memory low. Available memory on the panel is insufficient to load or run the current project.
    Reduce the project size by removing unused screens, alarms, or recipes. Ensure no unnecessary background tasks are running. Consider upgrading to a panel with greater memory capacity if the project cannot be reduced.
    Event ID: 50000
    Firmware update error. The firmware update process was interrupted or failed to complete.
    Restart the panel and attempt the firmware update again using the correct firmware version for the OP 77B. Ensure stable power supply during the update process and use the correct ProSave or WinCC flexible tool.
    Event ID: 70000
    Internal device error detected. A hardware fault has been identified within the panel.
    Perform a panel restart. If the error persists, note the full event ID details and contact Siemens technical support or arrange for hardware inspection and repair.
    Event ID: 80000
    Configuration error. The loaded project contains settings or objects incompatible with the panel hardware or firmware version.
    Verify that the project was compiled for the correct panel type and firmware version in WinCC flexible. Recompile and re-download the project after correcting any compatibility issues.

    Frequently Asked Questions

    What communication interfaces does the OP 77B support?

    The OP 77B supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs.

    Which software is used to configure the Siemens 6AV6355-1CA47-7EP0?

    The OP 77B is configured using Siemens WinCC flexible 2005 or later versions. ProSave can also be used for firmware updates and data backup operations.

    What is the supply voltage for the OP 77B panel?

    The panel operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to avoid operational issues.

    What is the front panel IP protection rating of the OP 77B?

    The front panel of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for typical industrial panel installations.

    Can the OP 77B be used with third-party PLCs?

    The OP 77B is primarily designed for use with Siemens SIMATIC controllers via MPI and PROFIBUS DP. Connectivity to third-party PLCs is limited and depends on available PROFIBUS DP driver support within WinCC flexible.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check for blown internal fuses or wiring faults. Verify that the power supply unit is providing stable voltage within tolerance.

    Correct any wiring faults and ensure the 24 V DC supply is stable. If the display backlight has failed, the panel will require repair or replacement of the backlight assembly. If no internal fuse is accessible, arrange for professional repair.

    HMI panel fails to communicate with the PLC

    Check the MPI or PROFIBUS DP cable for continuity and correct termination at both ends of the network. Verify that the panel address and PLC address are correctly configured and do not conflict with other network nodes.

    Replace damaged cables and ensure bus termination resistors are correctly installed at both ends of the network. Correct address settings in the WinCC flexible project and re-download the configuration to the panel.

    Project download from PC to panel fails

    Verify the transfer cable type and PC communication port settings. Confirm that the WinCC flexible project is compiled for the correct panel type and firmware version. Check that the panel is set to transfer mode.

    Use the correct PC-to-panel transfer cable and set the panel to transfer mode via the Start Center menu. Ensure the WinCC flexible software version is compatible with the installed panel firmware and retry the download.

    Function keys do not respond to operator input

    Check for physical damage to the keypad membrane or contamination around the key surfaces. Verify in the WinCC flexible project that the function keys are correctly assigned to screen objects or PLC tags.

    Clean the keypad surface and inspect for physical damage. If keys are unresponsive due to membrane failure, the panel will require hardware repair. If the issue is configuration-related, correct the key assignments in WinCC flexible and re-download the project.

    Panel repeatedly restarts or enters a boot loop

    Check the 24 V DC supply for voltage drops or instability under load. Inspect the project for configuration errors that may cause a runtime crash. Verify that the installed firmware version is compatible with the loaded project.

    Stabilize the power supply and ensure it meets the panel's current requirements. Use ProSave to perform a factory reset and re-download a verified project. Update the firmware to the latest compatible version if instability persists.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart