Siemens 6AV6355-1CA47-7EM0 OP 77B
€ 1.025,73
The Siemens 6AV6355-1CA47-7EM0 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This unit is a compact, key-operated panel designed for machine-level operator control and monitoring tasks. As part of the SIMATIC HMI Basic Panels generation, it provides a reliable human-machine interface solution for straightforward automation applications.
The OP 77B features a 4-inch STN monochrome display with a resolution of 320 x 240 pixels, capable of rendering text and simple graphics for process visualization. It supports communication via MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, enabling integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers onboard memory for project data storage. It operates on a 24 V DC supply and is rated to IP65 on the front face, providing protection against dust and water ingress in industrial environments.
The OP 77B is widely used in manufacturing, packaging, and process industries where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and keypad-based operation make it suitable for control cabinets and machine panels with limited space. The panel is particularly common in applications involving SIMATIC S7 PLC systems where basic process monitoring and parameter adjustment are needed.
Technical Specifications
| Display Size | 4 inch |
|---|---|
| Display Type | STN monochrome |
| Display Resolution | 320 x 240 pixels |
| Input Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP, RS-422/RS-485 |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Configuration Software | WinCC flexible 2008 or higher |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address settings and ensure the PLC is in RUN mode. Confirm baud rate settings match on both devices. - Event ID: 10001
- Connection to the PLC has been interrupted during runtime operation.
Inspect the communication cable for damage or loose connectors. Verify the PLC is powered and operational. Re-establish the connection and check for network address conflicts. - Event ID: 20000
- Project download error. The project data could not be transferred to the panel successfully.
Check the transfer cable and PC interface settings in WinCC flexible. Ensure the panel is in transfer mode before initiating the download. Retry the download after restarting both the PC and the panel. - Event ID: 40000
- System memory low. The panel's available memory for runtime operation is insufficient.
Reduce the project size by removing unused screens, tags, or graphics. Optimize the project in WinCC flexible and re-download the project to the panel. - Event ID: 70010
- Illegal tag address. A configured tag references an address that does not exist or is out of range in the connected PLC.
Open the project in WinCC flexible and verify all tag addresses against the PLC's data block or memory layout. Correct any invalid addresses and re-download the project. - Event ID: 70011
- Tag read error. The panel was unable to read the value of a configured tag from the PLC.
Check that the referenced PLC memory area is accessible and not write-protected. Verify the data type assigned to the tag matches the PLC variable. Confirm the communication link is stable. - Event ID: 80001
- Panel configuration file is corrupt or missing. The runtime cannot load the project data.
Re-download the project from WinCC flexible to the panel. If the error persists, perform a factory reset of the panel and re-transfer the project.
Frequently Asked Questions
Which PLCs are compatible with the Siemens OP 77B (6AV6355-1CA47-7EM0)?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with S7-200 via RS-422/RS-485 using the PPI protocol.
What software is required to configure the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are created on a PC and then transferred to the panel via a PC/PPI cable or MPI adapter.
What is the supply voltage for the 6AV6355-1CA47-7EM0?
The panel operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to avoid operational issues.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B is rated to IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.
Can the OP 77B display graphics and images?
The OP 77B supports basic graphics and bitmap images on its monochrome STN display. Complex color graphics are not supported due to the monochrome display technology.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuses or wiring faults in the control cabinet.
Ensure the 24 V DC supply is within tolerance and correctly wired to the panel terminals. If the supply is confirmed good but the display remains off, the internal power supply board or backlight may require replacement.
Panel shows 'No connection to PLC' message at runtime
Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment.
Replace or reseat the communication cable. Confirm that the PLC station address and baud rate configured in WinCC flexible match the actual PLC settings. Ensure no address conflicts exist on the network.
Project download fails or transfer does not start
Confirm the panel is set to transfer mode by navigating to the panel's start center and selecting 'Transfer'. Check that the correct communication interface and baud rate are selected in WinCC flexible's transfer settings.
Restart both the panel and the configuration PC. Use a known-good transfer cable or MPI adapter. If using USB-to-serial adapters, ensure the correct driver is installed and the COM port is correctly assigned.
Keypad buttons are unresponsive or intermittently fail
Inspect the keypad membrane for physical damage, contamination, or wear. Check the internal ribbon cable connection between the keypad membrane and the main PCB.
Clean the keypad surface with a dry cloth. If individual keys are consistently unresponsive, the keypad membrane assembly will need to be replaced. Reseat the ribbon cable connector if accessible during repair.
Panel restarts repeatedly or enters a boot loop
Check the 24 V DC supply for voltage drops or instability under load. Inspect the project file for corruption by attempting to reload the project from WinCC flexible.
Stabilize the power supply and ensure adequate current capacity. Perform a factory reset of the panel and re-download a freshly compiled project from WinCC flexible. If the issue persists, the main CPU board may require replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page