Siemens 6AV6355-1CA47-7DM2 OP 77B
€ 920,41
The Siemens 6AV6355-1CA47-7DM2 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing operators with a straightforward interface for monitoring and controlling industrial processes. The OP 77B series is part of the broader SIMATIC HMI Basic Panels generation and is engineered for integration into standard control cabinet doors and machine panels.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels, offering clear text and basic graphic visualization. It supports communication via MPI and PROFIBUS DP interfaces, enabling direct connection to Siemens S7-200, S7-300, and S7-400 PLCs without requiring an additional communication module. The panel is configured using Siemens WinCC flexible software and provides function keys for operator input, with LED indicators for status feedback. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The OP 77B is widely used in manufacturing, packaging, and process automation environments where a cost-effective, compact operator interface is required at the machine level. Its robust construction and compatibility with the SIMATIC S7 controller family make it suitable for applications in the automotive, food and beverage, and general machine-building industries. The panel is particularly well-suited for retrofit and upgrade projects replacing older OP7 and OP17 operator panels.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Colors | Monochrome (blue/white) |
| Input Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Configuration Software | WinCC flexible 2005 or higher |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS DP cable connections and terminating resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode. - Event ID: 10001
- Connection to the PLC was interrupted during operation.
Inspect the communication cable for damage or loose connectors. Verify bus termination and cable shielding. Restart the HMI panel and PLC if the connection is not automatically restored. - Event ID: 20000
- Project download error. The configuration project could not be transferred to the panel successfully.
Check the PC-to-panel transfer cable and connection. Ensure the panel is set to transfer mode. Verify WinCC flexible project compatibility with the panel firmware version. - Event ID: 40000
- System memory error. Internal memory fault detected during startup or operation.
Perform a factory reset of the panel. Re-download the project. If the fault persists, the internal memory may be defective and the unit should be sent for repair. - Event ID: 50000
- Firmware version mismatch. The firmware on the panel is incompatible with the loaded project.
Update the panel firmware to the version required by the WinCC flexible project. Use the ProSave tool or WinCC flexible to perform the firmware update. - Event ID: 70000
- Tag read/write error. The HMI panel cannot read from or write to a configured PLC tag.
Verify the PLC tag addresses in the WinCC flexible project match the actual PLC data block or memory addresses. Check PLC program for address conflicts.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B is compatible with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.
What software is used to configure the Siemens 6AV6355-1CA47-7DM2?
The panel is configured using Siemens WinCC flexible 2005 or later versions. The project is transferred to the panel via a PC adapter cable or PROFIBUS connection.
What is the supply voltage for the OP 77B?
The OP 77B operates on a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid operational issues.
Can the OP 77B replace older Siemens operator panels such as the OP7 or OP17?
Yes, the OP 77B is designed as a functional replacement for the OP7 and OP17 operator panels, offering compatible communication interfaces and a similar form factor to simplify retrofit installations.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for installation in industrial cabinet doors.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the supply is within the specified range and that the connector is firmly seated.
Restore correct 24 V DC supply. If voltage is correct and display remains blank, inspect the internal fuse and replace if blown. If the fault persists, the display or power supply board may require replacement.
Panel cannot communicate with the PLC
Verify MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Check bus termination resistors are correctly placed at both ends of the bus segment. Confirm the panel address and PLC address in the project configuration.
Replace or reseat the communication cable. Correct any address conflicts in the WinCC flexible project. Ensure bus termination is active only at the physical ends of the network segment.
Project transfer from PC to panel fails
Confirm the panel is in transfer mode before initiating the download. Check the PC adapter cable type and driver installation on the PC. Verify the communication settings in WinCC flexible match the panel connection.
Set the panel to transfer mode via the start screen. Use the correct PC adapter (USB or MPI) with up-to-date drivers. Re-attempt the project transfer. If unsuccessful, perform a factory reset on the panel and retry.
Function keys do not respond to operator input
Check whether the panel is in transfer mode or loader mode, which disables normal operation. Inspect the keypad membrane for physical damage or contamination.
Exit transfer or loader mode and return the panel to runtime mode. If keys are physically damaged, the keypad membrane assembly should be replaced by a qualified technician.
Panel repeatedly restarts or shows a boot loop
This may indicate a corrupted project file or a firmware issue. Attempt to access the panel loader screen during startup to assess the firmware and project status.
Perform a factory reset and re-download a valid WinCC flexible project. If the boot loop continues, update the panel firmware using the ProSave utility. If hardware failure is suspected, return the unit for repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page