Siemens 6AV6355-1CA47-7DF2 OP 77B
€ 2.070,40
The Siemens 6AV6355-1CA47-7DF2 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. It is designed for machine-level human-machine interface applications, providing a compact and cost-effective solution for operator control and monitoring tasks. This unit is part of Siemens' established HMI portfolio and is configured and programmed using WinCC flexible software.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a membrane keypad for operator input, eliminating the need for a touchscreen. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel operates on a 24 V DC supply and is rated to IP65 on the front face, providing protection against dust and water ingress in industrial environments.
The OP 77B is widely used in manufacturing, packaging, and process automation applications where a simple, reliable operator interface is required at the machine level. Its compact form factor and keypad-based operation make it suitable for control cabinets and machine panels with limited space. The panel is commonly found in applications such as conveyor systems, pumping stations, and general-purpose machinery where basic process visualization and parameter entry are required.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Colors | Monochrome (blue/white) |
| Input Method | Membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible 2005 or higher |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 10000
- Connection to the PLC could not be established or was interrupted during operation.
Check MPI or PROFIBUS DP cable connections, verify PLC address settings, and confirm the PLC is powered and in RUN mode. - Event ID: 10001
- Communication timeout between the HMI panel and the configured PLC controller.
Verify network cable integrity, check bus termination resistors, and confirm matching baud rate settings on both devices. - Event ID: 20000
- Project download failed or project data on the panel is corrupted.
Re-download the project from WinCC flexible to the panel. Ensure the WinCC flexible version is compatible with the panel firmware. - Event ID: 40000
- Internal panel memory error detected during startup or operation.
Perform a factory reset of the panel and re-download the project. If the fault persists, the panel may require hardware repair or replacement. - Event ID: 50000
- Panel firmware version is incompatible with the loaded project file.
Update the panel firmware to the version required by the WinCC flexible project, then re-download the project. - Event ID: 60000
- Power supply voltage is outside the permissible operating range.
Measure the 24 V DC supply at the panel connector. Ensure supply voltage is within the specified tolerance and check for loose wiring. - Event ID: 70000
- Tag or variable address configured in the project cannot be found in the connected PLC.
Verify that all tag addresses in the WinCC flexible project match the actual data block and variable addresses in the PLC program.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with other Siemens controllers that support these protocols.
What software is used to configure and program the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via an MPI or PROFIBUS DP connection.
What is the supply voltage for the 6AV6355-1CA47-7DF2?
The panel requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid operational faults.
Does the OP 77B have a touchscreen?
No, the OP 77B uses a membrane keypad for operator input and does not feature a touchscreen. Navigation and data entry are performed using the physical keys.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B is rated to IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial panel mounting.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the panel power connector using a multimeter. Inspect the wiring for loose or reversed connections.
Ensure the supply voltage is within the 24 V DC operating range. Correct any wiring faults. If the supply is correct and the display remains blank, the internal power supply or display unit may require repair.
Panel displays a communication error and cannot connect to the PLC
Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination is correctly applied at both ends of the network segment.
Replace or reseat the communication cable. Confirm that the PLC address and baud rate configured in WinCC flexible match the actual PLC settings. Ensure the PLC is powered on and in RUN mode.
Project download from WinCC flexible fails or is interrupted
Check the USB or MPI/PROFIBUS connection between the programming PC and the panel. Verify that the WinCC flexible software version is compatible with the panel firmware version.
Update the panel firmware if required, then retry the download. Ensure no other active connections are using the communication port during the transfer.
Keypad buttons are unresponsive or intermittently fail
Inspect the membrane keypad for physical damage, contamination, or wear. Check for any visible damage to the keypad ribbon cable connector inside the panel.
Clean the keypad surface with a dry cloth. If individual keys are permanently unresponsive, the membrane keypad assembly will need to be replaced as a spare part.
Panel repeatedly restarts or enters a boot loop
Check the 24 V DC supply for voltage fluctuations or drops under load. Inspect the project file for configuration errors that may cause a runtime crash on startup.
Stabilize the power supply and ensure adequate current capacity. Perform a factory reset and re-download a verified project file. If the issue persists, the panel hardware may require inspection and repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page