• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7DE0 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7DE0 OP 77B

    € 419,36

    Reset
    Clear
    SKU: 6AV6355-1CA47-7DE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7DE0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels series. It is a compact, key-operated operator panel designed for straightforward machine-level human-machine interface applications. This unit provides a text-based display interface and is part of Siemens' established line of operator panels for industrial automation environments.

    The OP 77B features a 4-line STN text display capable of showing alphanumeric characters, function keys, and system keys for direct operator input without a touchscreen. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel operates on 24 V DC supply voltage and is designed for panel front mounting with an IP65 protection rating on the front face, making it suitable for industrial enclosure integration.

    The OP 77B is commonly deployed in manufacturing machinery, conveyor systems, packaging equipment, and process automation installations where a cost-effective, robust operator interface is required. Its compatibility with the SIMATIC S7 PLC family makes it a practical choice for facilities already operating within the Siemens automation ecosystem. The panel is configured using WinCC flexible software, which allows straightforward project engineering and download.

    Technical Specifications

    Display Type STN text display
    Display Lines 4 lines
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Permissible Voltage Range 19.2 – 28.8 V DC
    Power Consumption 4 W (typical)
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 – 90% (non-condensing)
    Mounting Panel front mounting
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2008 or later

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP 77B and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect physical cable integrity and connector seating. Check for address conflicts on the MPI or PROFIBUS network. Restart the panel and PLC if the connection does not recover automatically.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel successfully.
    Verify the PC-to-panel transfer cable is correctly connected. Ensure WinCC flexible is set to the correct transfer mode and the panel is in transfer mode. Retry the download.
    Event ID: 40000
    System memory error detected on the operator panel.
    Perform a panel reset to factory defaults. Re-download the project. If the error persists, the internal memory may be faulty and the unit should be repaired or replaced.
    Event ID: 50000
    Operating system error or firmware fault on the panel.
    Attempt a controlled restart of the panel. If the fault recurs, update or reinstall the panel firmware using the appropriate Siemens ProSave tool.
    Event ID: 60000
    Configuration or tag limit exceeded. The number of configured tags or screens exceeds the capacity of the OP 77B.
    Review the WinCC flexible project and reduce the number of tags or screens to within the panel's supported limits. Re-download the corrected project.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7DE0)?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.

    What software is used to configure and program the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via a PC adapter cable or PROFIBUS connection.

    What is the supply voltage for the 6AV6355-1CA47-7DE0?

    The panel requires a 24 V DC supply voltage, with a permissible operating range of 19.2 V DC to 28.8 V DC.

    Does the OP 77B support touchscreen input?

    No, the OP 77B is a key-operated panel. It uses physical function keys and system keys for operator input and does not have a touchscreen.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the voltage is within the 19.2–28.8 V DC permissible range. Inspect the supply wiring for loose connections or blown fuses in the control cabinet.

    Correct any supply voltage issues or wiring faults. If the supply is confirmed good and the display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair.

    Panel displays 'No connection to PLC' or communication error message

    Check the MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination resistors are correctly placed at both ends of the network. Confirm the PLC address in the WinCC flexible project matches the physical PLC address setting.

    Reseat all connectors, correct termination, and verify address settings. If using PROFIBUS, check the configured baud rate matches the network. Restart both the panel and PLC after corrections.

    Panel does not enter transfer mode for project download

    Confirm the panel is set to transfer mode via the Start Center or loader menu. Check that the PC adapter or transfer cable is correctly connected and the appropriate COM port or USB driver is installed on the engineering PC.

    Navigate to the panel's Start Center and select 'Transfer'. Ensure WinCC flexible is configured with the correct transfer channel. Replace the transfer cable if communication still cannot be established.

    Function keys do not respond or produce incorrect actions

    Check the downloaded project configuration in WinCC flexible to verify that function key assignments are correctly defined. Test whether the issue occurs on all screens or only specific ones.

    Correct any misconfigured key assignments in the WinCC flexible project and re-download. If keys are physically unresponsive on all screens, the keypad membrane may be worn or damaged and requires replacement.

    Panel repeatedly restarts or shows a boot loop

    This may indicate a corrupted project file or a firmware issue. Attempt to access the Start Center during boot by pressing the appropriate key combination. Check whether the panel boots correctly without a project loaded.

    Use Siemens ProSave to restore or update the panel firmware. After firmware restoration, re-download the project from WinCC flexible. If the boot loop persists, the panel hardware may require professional repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart