• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7DC6 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7DC6 OP 177B

    € 1.309,77

    Reset
    Clear
    SKU: 6AV6355-1CA47-7DC6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7DC6 is an operator panel belonging to the SIMATIC OP 177B series, part of Siemens' SIMATIC HMI product line. This unit is a compact, panel-mounted operator panel designed for machine-level visualization and control tasks. It provides a robust interface for process monitoring and operator interaction in industrial automation environments.

    The OP 177B features a 5.7-inch STN display with a resolution of 320 x 240 pixels (QVGA) and supports 256 colors, combined with a membrane keypad for operator input. It is equipped with PROFIBUS DP and MPI communication interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel operates on 24 V DC and offers configurable function keys, a USB port for project transfer, and is configured using WinCC flexible engineering software.

    The OP 177B is widely deployed in machine building, automotive manufacturing, food and beverage processing, and general factory automation. Its compact form factor and compatibility with the SIMATIC controller ecosystem make it suitable for decentralized HMI installations on individual machines or production cells where a dedicated operator interface is required.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Type STN color LCD
    Display Colors 256 colors
    Input Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface PROFIBUS DP, MPI, RS-422/485
    USB Interface USB Type A (for project transfer and backup)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2005 or higher

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check the PROFIBUS/MPI cable connections and termination resistors. Verify the PLC address settings in the WinCC flexible project match the physical configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Timeout error on the communication link. The HMI did not receive a response from the PLC within the expected time window.
    Check network cable integrity and connector seating. Reduce bus load or increase the communication timeout parameter in the HMI project settings.
    Event ID: 20000
    Project download error. A fault occurred during the transfer of the HMI project to the panel.
    Verify the USB cable or network connection used for transfer. Ensure WinCC flexible version is compatible with the panel firmware. Retry the download after restarting the panel.
    Event ID: 40000
    System memory low. The panel's available working memory is insufficient to load or run the current project.
    Reduce the project size by optimizing graphics and tag counts. Delete unused screens and archived data. Perform a panel reset if the condition persists.
    Event ID: 50000
    Internal device error. A hardware or firmware fault has been detected within the panel.
    Perform a factory reset of the panel. If the error persists after reset and project reload, the unit may require repair or replacement of internal components.
    Event ID: 60000
    Configuration error. The loaded project contains settings or references that are incompatible with the current panel firmware version.
    Update the panel firmware to the version required by the WinCC flexible project. Re-download the project after the firmware update is complete.
    Event ID: 70000
    Tag acquisition error. One or more process tags defined in the project cannot be read from the PLC.
    Verify that the PLC data block addresses referenced in the HMI project exist and are accessible. Check PLC program for address changes and update the HMI project accordingly.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6355-1CA47-7DC6)?

    The OP 177B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with S7-1200 and third-party controllers through RS-422/485 serial connections using appropriate drivers in WinCC flexible.

    What software is used to configure and program the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2005 or later versions. Projects are transferred to the panel via USB or through the PROFIBUS/MPI network connection.

    What is the supply voltage for the 6AV6355-1CA47-7DC6?

    The panel requires a 24 V DC supply voltage. It is recommended to use a regulated SELV power supply meeting IEC 60364-4-41 requirements.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel door mounting.

    Can the OP 177B display be used as a touch screen?

    No, the OP 177B in this configuration uses a membrane keypad with dedicated function keys for operator input. It does not feature a touch screen; operator interaction is performed via the physical keys on the panel.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the specified tolerance. Inspect the internal fuse if accessible.

    Ensure the power supply output is stable at 24 V DC and capable of supplying the required current. Replace the power supply if voltage is out of range. If supply is correct and display remains blank, the panel backlight or internal power board may require replacement.

    HMI shows 'No connection to PLC' or communication error on startup

    Verify the PROFIBUS DP or MPI cable is correctly connected and terminated at both ends. Check that the bus address configured in the WinCC flexible project matches the physical PLC address setting.

    Replace or reseat the communication cable. Confirm correct bus termination resistors are installed at both ends of the PROFIBUS segment. Correct the PLC address in the HMI project and re-download if there is a mismatch.

    Panel freezes or becomes unresponsive during operation

    Check if the panel is running a project that exceeds its memory or processing capacity. Review the complexity of the active screen and the number of tags being polled simultaneously.

    Perform a panel restart by cycling the 24 V DC power supply. If the issue recurs, optimize the WinCC flexible project by reducing simultaneous tag acquisitions and screen complexity. Update panel firmware to the latest compatible version.

    Project download fails via USB

    Verify the USB cable is functional and correctly connected. Confirm that the WinCC flexible software version is compatible with the panel firmware version. Check that the panel is in transfer mode.

    Switch the panel to transfer mode via the Start Center menu before initiating the download. Use a known-good USB cable. If incompatibility is detected, update the panel firmware using the Siemens ProSave tool before re-attempting the project transfer.

    Function keys do not respond or produce incorrect inputs

    Inspect the membrane keypad for physical damage, contamination, or deformation. Verify in the WinCC flexible project that the function keys are correctly assigned to the intended actions.

    Clean the keypad surface with a dry cloth. If keys are physically damaged, the membrane keypad assembly requires replacement. Verify and correct key assignments in the WinCC flexible project and re-download to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart