
Siemens 6AV6355-1CA47-7DC0 OP 77B
€ 419,36
The Siemens 6AV6355-1CA47-7DC0 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This unit is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward interface for monitoring and controlling automated processes. The OP 77B series is part of the broader SIMATIC HMI Basic Panels family and is engineered for integration into standard industrial control environments.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a backlit screen for readability in varying ambient light conditions. It supports communication via MPI and PROFIBUS DP interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs without an additional communication module. The panel is configured using WinCC flexible software and offers a membrane keypad with function keys for operator input, with no touchscreen capability. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The OP 77B is widely deployed in manufacturing, packaging, and process automation environments where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine enclosures with limited space. Industries such as automotive, food and beverage, and general machine building commonly use this panel for local operator control and status monitoring tasks.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Size | 4 inch |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 4 W |
| Communication Interface | MPI, PROFIBUS DP |
| Input Method | Membrane keypad with function keys |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Configuration Software | WinCC flexible 2005 or higher |
| Mounting | Panel mount |
| Certifications | CE, UL, cULus |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to the PLC was interrupted during operation.
Inspect the communication cable for damage or loose connectors. Check bus termination and cable shielding. Restart both the HMI panel and the PLC if the connection is not restored automatically. - Event ID: 20000
- Project download error. The configuration project could not be transferred to the panel successfully.
Verify the USB or serial transfer cable is properly connected. Ensure WinCC flexible is configured with the correct panel type and communication settings. Retry the download after restarting the panel in transfer mode. - Event ID: 40000
- System error on the HMI panel. An internal firmware or runtime error has occurred.
Perform a panel restart. If the error persists, reload the project firmware using WinCC flexible and re-download the project. Contact Siemens technical support if the fault recurs. - Event ID: 50000
- Configuration error detected. The loaded project is incompatible with the panel firmware version.
Update the panel firmware to match the WinCC flexible project version. Re-download the project after the firmware update is complete. - Event ID: 60000
- Backlight failure or display error detected.
Check the 24 V DC power supply voltage at the panel connector. If the backlight has failed, the panel display unit may require replacement. Verify supply voltage is within the specified 24 V DC range.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7DC0)?
The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. It can also communicate with S7-200 via PPI protocol.
What software is used to configure the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2005 or later versions. Projects are downloaded to the panel via a USB or serial PC/PPI cable.
Does the OP 77B have a touchscreen?
No, the OP 77B does not have a touchscreen. Operator input is performed exclusively via the membrane keypad, which includes system keys and configurable function keys.
What is the supply voltage for the 6AV6355-1CA47-7DC0?
The panel operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to prevent operational faults.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B is rated IP65, providing protection against dust ingress and low-pressure water jets. The rear of the panel is rated IP20.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel power connector. Check for a blown internal fuse or wiring fault on the supply line.
Restore the 24 V DC supply to within specification. If the supply is correct and the display remains blank, the backlight or internal power board may have failed and the panel should be sent for repair or replacement.
HMI panel cannot communicate with the PLC
Verify the MPI or PROFIBUS DP address configured in the HMI project matches the address set on the PLC. Check the communication cable for continuity and correct pin assignment. Inspect bus termination at both ends of the network.
Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged cables and ensure proper bus termination resistors are installed at the cable ends.
Panel repeatedly enters transfer mode on startup
The panel may be configured to start in transfer mode, or the project stored in the panel memory is corrupted or missing.
Download a valid project to the panel using WinCC flexible. After a successful download, configure the startup behavior in the project settings to boot directly into runtime mode.
Function keys do not respond to operator input
Inspect the membrane keypad for physical damage or contamination beneath the keypad surface. Verify that the function keys are correctly assigned in the WinCC flexible project.
Clean the keypad surface and check for mechanical damage. If key assignments are missing in the project, reconfigure and re-download the project. If the keypad membrane is damaged, the panel requires hardware repair.
Project download fails or times out
Check the USB or serial cable connection between the PC and the panel. Confirm the panel is in transfer mode and that the correct communication port and baud rate are selected in WinCC flexible.
Restart the panel in transfer mode by holding the appropriate key combination during boot. Select the correct COM port and transfer settings in WinCC flexible and retry the download.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page



