Siemens 6AV6355-1CA47-7CJ3 OP 77B
€ 1.995,00
The Siemens 6AV6355-1CA47-7CJ3 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a straightforward interface for monitoring and controlling industrial processes. As part of the SIMATIC HMI Basic Panels generation, the OP 77B offers a membrane keypad-based interface suited for environments where a touch screen is not required.
The OP 77B features a monochrome STN LCD display and is equipped with function keys and system keys for direct operator interaction. It supports the MPI and PROFIBUS DP communication protocols, enabling seamless integration into Siemens S7 PLC environments. The panel is configured using WinCC flexible software and offers onboard memory for storing project data, recipes, and alarm logs. It operates on a 24 V DC supply and is rated to IP65 on the front face, making it suitable for panel-mount installations in industrial enclosures.
The OP 77B is widely used in manufacturing, automotive, food and beverage, and general machine-building industries where a cost-effective, reliable operator interface is needed. It is particularly suited for applications requiring direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. Its compact form factor and robust membrane keypad design make it appropriate for machines with limited panel space and demanding environmental conditions.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Size | 4 inches |
| Display Colors | Monochrome (blue/white) |
| Input Voltage | 24 V DC |
| Power Consumption | Max. 6 W |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible 2008 or higher |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during startup; project data on the device is invalid or corrupted.
Reload the project using WinCC flexible. Ensure the correct project version is transferred to the panel. - Event ID: 20000
- Communication error on MPI or PROFIBUS DP interface; connection to the PLC has been lost.
Check MPI/PROFIBUS cable connections and termination resistors. Verify bus address settings on both the panel and PLC. - Event ID: 40000
- Tag read/write error; a configured tag cannot be accessed on the connected controller.
Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts. - Event ID: 50000
- Recipe data error; recipe records cannot be read from or written to the panel memory.
Check available panel memory. Re-transfer the project and recipe data. If the problem persists, perform a factory reset and reload the project. - Event ID: 70000
- System memory low warning; available memory for runtime operation is critically low.
Reduce the number of active alarms, recipe entries, or logged data. Optimize the project size and re-transfer to the panel. - Event ID: 110000
- Firmware update error; firmware transfer to the panel was interrupted or failed.
Restart the firmware update procedure using ProSave or WinCC flexible. Ensure a stable power supply and communication connection during the update.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B?
The OP 77B is compatible with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-1200 and S7-1500 PLCs in certain configurations using appropriate drivers in WinCC flexible.
What software is used to configure the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are transferred to the panel via MPI, PROFIBUS DP, or a USB/serial connection using ProSave.
What is the supply voltage for the 6AV6355-1CA47-7CJ3?
The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid operational issues.
What is the front panel protection rating of the OP 77B?
The OP 77B has an IP65 protection rating on the front face, making it resistant to dust and water jets. The rear of the unit is rated IP20.
Can the OP 77B be used with third-party PLCs?
The OP 77B is primarily designed for use with Siemens SIMATIC PLCs via MPI and PROFIBUS DP. Limited support for third-party controllers may be available through specific WinCC flexible communication drivers, but compatibility should be verified before deployment.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify the supply is within the specified voltage range and that the connector is properly seated.
Restore correct 24 V DC supply. If the supply is correct and the display remains blank, the internal power supply or backlight may be faulty and the unit should be sent for repair or replacement.
Panel fails to communicate with the PLC
Verify MPI or PROFIBUS DP cable connections at both the panel and PLC. Check bus termination at both ends of the network and confirm the panel bus address does not conflict with other devices.
Replace or reseat the communication cable. Correct the bus address in the panel startup menu. Ensure termination resistors are active only at the physical ends of the bus segment.
Project cannot be transferred to the panel
Confirm the communication interface selected in WinCC flexible matches the physical connection being used. Check that the panel is in transfer mode and that the correct COM port or interface is selected on the PC.
Set the panel to transfer mode via the Start Center menu. Verify PC interface settings in WinCC flexible. If using a serial adapter, ensure the correct driver is installed and the cable is a valid programming cable.
Alarms or tags display incorrect values
Compare the tag addresses configured in the WinCC flexible project against the actual PLC memory addresses. Check for address offset errors or data type mismatches.
Correct the tag addresses in the WinCC flexible project and re-transfer the updated project to the panel. Ensure the PLC program has not been modified in a way that shifts memory addresses.
Panel repeatedly restarts or enters an error loop
Check for corrupted project data on the panel. Attempt to access the Start Center during boot by pressing the appropriate key combination. Review the event log if accessible.
Perform a factory reset via the Start Center and re-transfer a valid project using WinCC flexible. If the problem persists after reloading the project, the panel hardware may require servicing.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page