Siemens 6AV6355-1CA47-7CE0 OP 77B
€ 241,70
The Siemens 6AV6355-1CA47-7CE0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. This compact panel provides a text-based operator interface for machine-level visualization and control tasks. It is designed for use with Siemens SIMATIC S7 PLCs and other compatible controllers, offering a reliable and cost-effective HMI solution.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 32 pixels, capable of displaying up to 4 lines of text. It includes a membrane keypad with function keys for direct operator input and supports MPI and PROFIBUS DP communication interfaces for integration into existing automation networks. The unit operates on a 24 V DC supply and is configured using Siemens WinCC flexible software, supporting alarm management, recipe handling, and simple process visualization.
The OP 77B is widely used in manufacturing, packaging, and process automation environments where a compact, robust operator interface is required at the machine level. Its small form factor and panel-mount design make it suitable for integration into control cabinets and machine enclosures. The panel is particularly common in applications requiring straightforward status display, parameter entry, and alarm acknowledgment without the need for graphical visualization.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 32 pixels |
| Display Lines | 4 lines of text |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 3 W (typical) |
| Communication Interface | MPI, PROFIBUS DP |
| Configuration Software | WinCC flexible 2005 or higher |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mount |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to the PLC was established but subsequently lost during operation.
Inspect cable integrity and connector seating. Check for network address conflicts on the MPI or PROFIBUS segment. Verify bus termination at both ends of the network. - Event ID: 40000
- Project download error. The configuration project could not be transferred to the panel successfully.
Verify the PC-to-panel transfer cable is correctly connected. Ensure the panel is set to transfer mode. Check that the WinCC flexible project is compiled without errors before downloading. - Event ID: 40010
- Insufficient memory on the HMI device to store the downloaded project.
Reduce the project size by removing unused tags, alarms, or recipes. Perform a factory reset on the panel to clear residual data before re-downloading. - Event ID: 20000
- Tag read error. A configured tag could not be read from the PLC.
Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Confirm the PLC program contains the referenced address. - Event ID: 20001
- Tag write error. A value could not be written to the configured PLC tag.
Check that the target PLC memory area is not write-protected. Verify the tag data type in the HMI project matches the PLC variable type. - Event ID: 50000
- System fault on the HMI panel. An internal hardware or firmware error has been detected.
Perform a panel restart by cycling the 24 V DC power supply. If the fault persists, perform a factory reset or contact Siemens technical support for firmware recovery.
Frequently Asked Questions
What communication interfaces does the OP 77B support?
The OP 77B supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs as well as third-party controllers with compatible protocols.
What software is required to configure the 6AV6355-1CA47-7CE0?
The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. The project is downloaded to the panel via a PC adapter cable connected to the MPI or PROFIBUS DP interface.
What is the supply voltage for this operator panel?
The OP 77B requires a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to prevent operational faults.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial environments.
Can the OP 77B display graphical content?
No, the OP 77B is a text-based operator panel with a monochrome LCD capable of displaying up to 4 lines of text. It does not support bitmap graphics or color visualization.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify polarity is correct and voltage is within specification.
Restore correct 24 V DC supply. If voltage is present and the display remains blank, the internal power supply or LCD backlight may have failed and the unit should be sent for repair or replacement.
Panel shows 'Connecting…' and cannot establish communication with PLC
Verify MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Check that bus termination resistors are correctly installed at the physical ends of the network segment.
Replace or reseat the communication cable. Confirm the PLC station address in the HMI project matches the actual PLC configuration. Ensure no address conflicts exist on the bus.
Project download fails or transfer cannot be initiated
Confirm the panel is set to transfer mode by navigating to the panel's loader menu. Check the PC adapter cable connection and that the correct COM port or USB adapter is selected in WinCC flexible.
Set the panel to transfer mode, select the correct interface in WinCC flexible transfer settings, and retry the download. If the issue persists, perform a factory reset on the panel before attempting the transfer again.
Function keys do not respond to operator input
Inspect the membrane keypad for physical damage, contamination, or deformation. Verify in the WinCC flexible project that the function keys are correctly assigned to events or tags.
Clean the keypad surface and check for mechanical damage. If keys are unresponsive due to hardware failure, the membrane keypad assembly requires replacement. Verify key assignments in the project configuration.
Alarm messages are not displayed on the panel
Check the alarm configuration in the WinCC flexible project to ensure alarm tags are correctly linked to PLC addresses. Verify the PLC is setting the alarm bits as expected using a PLC monitoring tool.
Correct any misconfigured alarm tag addresses in the WinCC flexible project and re-download to the panel. Confirm the PLC logic is activating the correct memory bits associated with the configured alarms.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page