Siemens 6AV6355-1CA47-7CD3 OP 177B
€ 3.495,00
The Siemens 6AV6355-1CA47-7CD3 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with touch and key-based operation, serving as a compact yet capable panel for process visualization and control. As part of the SIMATIC HMI comfort and mobile panel lineage, it integrates seamlessly into Siemens automation environments.
The OP 177B features a 5.7-inch STN display with a resolution of 320 x 240 pixels and supports both MPI and PROFIBUS DP communication interfaces, enabling direct connection to SIMATIC S7 PLCs. The panel includes configurable function keys, a numeric keypad, and supports WinCC flexible as its configuration software. It operates on a 24 V DC supply and is built to withstand industrial environments with a front-panel IP65 protection rating.
The OP 177B is widely deployed in manufacturing, machine building, and process automation industries where a robust and reliable operator interface is required at the machine level. It is commonly found on packaging machines, conveyor systems, and general-purpose industrial machinery where operators need to monitor process values, trigger commands, and acknowledge alarms. Its compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a standard choice for Siemens-based automation systems.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN LCD |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | 256 colors |
| Touch Technology | Resistive touchscreen with membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 8 W |
| Communication Interface | MPI, PROFIBUS DP |
| IP/Protection Rating | IP65 (front panel), IP20 (rear) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Configuration Software | WinCC flexible 2005 or higher |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI project configuration. Restart both the HMI and PLC if necessary. - Event ID: 10001
- Timeout error on the communication link. The HMI did not receive a response from the PLC within the expected time window.
Verify network cabling integrity and connector seating. Check for address conflicts on the MPI or PROFIBUS network. Reduce network load or increase the configured timeout value in WinCC flexible. - Event ID: 20000
- Project download error. The configuration project could not be transferred to the HMI panel successfully.
Ensure the correct transfer cable or network connection is used. Verify that the WinCC flexible project is compiled without errors before transfer. Check available memory on the HMI panel. - Event ID: 40000
- Tag read/write error. A process tag could not be read from or written to the connected controller.
Confirm the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for access protection on the relevant data areas. - Event ID: 50000
- System memory low warning. The available runtime memory on the HMI panel is critically low.
Reduce the number of active screens, alarms, or logged data. Archive or delete old alarm and data logs stored on the panel. Consider optimizing the WinCC flexible project to reduce memory usage. - Event ID: 60000
- Operating system error or runtime fault detected on the HMI panel.
Perform a controlled restart of the HMI panel. If the fault persists after restart, reload the WinCC flexible project. In persistent cases, perform a factory reset and re-download the project. - Event ID: 70000
- Alarm buffer overflow. The number of pending alarms has exceeded the buffer capacity of the HMI panel.
Acknowledge and clear active alarms on the panel. Review the alarm configuration in WinCC flexible to ensure alarm limits are correctly set and not triggering excessively. Increase the alarm buffer size if supported.
Frequently Asked Questions
What communication interfaces does the OP 177B (6AV6355-1CA47-7CD3) support?
The OP 177B supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to SIMATIC S7-300 and S7-400 PLCs without additional communication modules.
What software is required to configure the OP 177B?
The OP 177B is configured using Siemens WinCC flexible 2005 or a later version. Projects are compiled in WinCC flexible and downloaded to the panel via MPI, PROFIBUS, or a direct PC adapter cable.
What is the supply voltage for the OP 177B?
The OP 177B operates on a 24 V DC supply voltage. Ensure a stable, regulated 24 V DC power source is used to avoid panel faults or communication instability.
What is the front panel protection rating of the OP 177B?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in control cabinet doors where exposure to dust and water spray is possible.
Is the OP 177B compatible with SIMATIC S7-1200 or S7-1500 PLCs?
The OP 177B is primarily designed for use with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. Compatibility with S7-1200 or S7-1500 is limited and generally not recommended; newer HMI panels such as the KTP or Comfort series are preferred for those controllers.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within the specified tolerance and that the connector is fully seated.
Correct any supply voltage issues and reseat the power connector. If the display remains blank with correct supply voltage, the internal power supply board or backlight may be faulty and require replacement.
HMI panel fails to establish communication with the PLC
Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the bus address and baud rate configured in the HMI project match the PLC settings.
Replace or reseat the communication cable. Correct any address or baud rate mismatches in the WinCC flexible project and re-download the project to the panel. Ensure termination resistors are enabled only at the physical ends of the bus.
Touchscreen does not respond or responds inaccurately to touch input
Check whether the touchscreen responds at all or only in certain areas. Determine if the issue is present immediately after startup or develops over time, which may indicate a calibration drift or hardware fault.
Perform a touchscreen recalibration through the panel's Start Center or Control Panel settings. If recalibration does not resolve the issue, the touchscreen overlay may be damaged and require physical replacement.
Panel repeatedly restarts or enters an error loop after project download
Check the WinCC flexible project for configuration errors, unsupported functions, or memory overruns. Verify that the project was compiled for the correct HMI device type and firmware version.
Recompile the project in WinCC flexible after correcting any errors, then perform a clean transfer. If the issue persists, perform a factory reset of the panel via the Start Center and re-download the project from scratch.
Function keys or membrane keypad buttons do not respond
Test each key individually to determine if the fault is isolated to specific keys or affects all keys. Inspect the membrane keypad connector on the internal PCB for damage or poor contact.
Reseat the membrane keypad ribbon cable connector on the main board. If individual keys are unresponsive due to wear or damage, the membrane keypad assembly should be replaced as a unit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page