• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7CB2 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7CB2 OP 77B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7CB2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7CB2 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a straightforward interface for process monitoring and control. It operates as a standalone HMI device, communicating with SIMATIC PLCs and other compatible controllers to display process values and accept operator inputs.

    The OP 77B features a monochrome LCD display and a membrane keypad for operator input, making it suitable for environments where a robust, non-touch interface is preferred. It supports MPI and PROFIBUS DP communication interfaces for direct integration with Siemens S7-300 and S7-400 PLC families. The unit is configured using WinCC flexible software and supports alarm management, recipe handling, and trend display functions within its memory capacity.

    The OP 77B is widely deployed in manufacturing, process automation, and machine building applications where a cost-effective, reliable operator interface is required at the machine level. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine panels in industries such as automotive, food and beverage, and general factory automation. The device is well-suited for applications requiring straightforward status display and parameter entry without the complexity of a full graphical touchscreen panel.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Configuration Software WinCC flexible 2008
    Series/Product Family SIMATIC HMI OP 77B
    Certifications CE, UL
    Input Type Membrane keypad

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings and ensure the PLC is in RUN mode. Check baud rate configuration on both devices.
    Event ID: 10001
    Connection to the PLC was established but subsequently lost during operation.
    Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify PLC program is running and not in STOP mode.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel successfully.
    Verify the USB or MPI connection between the engineering PC and the panel. Ensure WinCC flexible version is compatible with the panel firmware version. Retry the transfer after restarting both devices.
    Event ID: 40000
    Tag read error. A configured tag could not be read from the PLC within the defined timeout period.
    Verify the tag address exists in the PLC program and the data block is present. Check communication settings and ensure the PLC is accessible. Review tag configuration in WinCC flexible for address errors.
    Event ID: 40001
    Tag write error. A value could not be written to the PLC tag from the operator panel.
    Check that the target PLC data area is not write-protected. Verify the tag address and data type match the PLC configuration. Ensure the PLC is in RUN mode and accepting write requests.
    System Fault: Configuration Mismatch
    The loaded project configuration does not match the connected panel type or firmware version.
    Re-download the project using the correct WinCC flexible version. Verify the target panel type selected during project creation matches the physical device. Update panel firmware if required.
    Event ID: 70010
    Internal device error or watchdog timeout. The panel has detected an internal fault condition.
    Perform a power cycle on the panel. If the fault persists, reset the panel to factory defaults and re-download the project. Contact Siemens technical support if the error recurs after reset.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens 6AV6355-1CA47-7CB2 OP 77B?

    The OP 77B is compatible with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 PLCs using the appropriate protocol settings.

    What software is used to configure the OP 77B panel?

    The OP 77B is configured using Siemens WinCC flexible 2008 or later compatible versions. Projects are created on a PC and downloaded to the panel via MPI or USB connection.

    What is the supply voltage for the 6AV6355-1CA47-7CB2?

    The panel requires a 24 V DC supply voltage for operation. Ensure the power supply is within the specified tolerance range to avoid device faults.

    What is the IP protection rating of the OP 77B front panel?

    The front panel of the OP 77B carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Does the OP 77B support recipe and alarm management functions?

    Yes, the OP 77B supports basic alarm management and recipe functions as configured within WinCC flexible. The number of alarms and recipes is limited by the available panel memory.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify polarity is correct and voltage is within the specified range.

    Correct any wiring errors or supply voltage issues. If supply voltage is confirmed correct and the display remains blank, the internal power supply or display unit may be faulty and the panel may require repair or replacement.

    Panel cannot communicate with the PLC

    Verify MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Check that bus termination resistors are correctly installed at both ends of the network. Confirm address settings on the panel match the configured network parameters.

    Correct any loose or damaged cable connections. Set the correct MPI or PROFIBUS address on the panel via the transfer settings menu. Ensure only the two physical end nodes have bus termination enabled.

    Project download from WinCC flexible fails

    Check the physical connection between the engineering PC and the panel, whether via MPI adapter or USB. Confirm the panel is in Transfer mode by accessing the panel's start center or control panel.

    Switch the panel to Transfer mode manually before initiating the download. Ensure the WinCC flexible project is configured for the correct panel type. Update panel firmware if version incompatibility is suspected.

    Alarm messages are not appearing on the panel during operation

    Verify that alarm tags are correctly configured in the WinCC flexible project and that the corresponding PLC bit addresses are correct. Check that the PLC program is actually setting the alarm bits.

    Correct any tag address mismatches in the WinCC flexible alarm configuration. Re-download the updated project to the panel and test alarm triggering from the PLC program.

    Panel repeatedly restarts or shows watchdog fault

    Check the 24 V DC supply for voltage dips or instability under load. Inspect the panel for signs of overheating or inadequate ventilation around the unit.

    Stabilize the power supply by using a dedicated 24 V DC source with adequate current capacity. Ensure the panel installation allows sufficient airflow. If restarts persist with a stable supply, the panel may require internal inspection or replacement of the main board.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart