• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7BE0 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7BE0 OP 77B

    € 1.861,89

    Reset
    Clear
    SKU: 6AV6355-1CA47-7BE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7BE0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. This unit provides a compact, keypad-based human-machine interface designed for straightforward machine-level operation and monitoring tasks. It is part of Siemens' established line of operator panels intended for integration into standard industrial control cabinets and machinery.

    The OP 77B features a 4-line STN monochrome display capable of showing text and simple graphics, with a membrane keypad for operator input including function keys and system keys. It communicates via MPI and PROFIBUS DP interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel supports configuration via WinCC flexible software and offers a compact, robust housing suited to industrial environments with an IP65 protection rating on the front face.

    The OP 77B is widely deployed in manufacturing, packaging, and process automation applications where a cost-effective, reliable text-based operator interface is required. It is commonly found on standalone machines, conveyor systems, and small automation cells where operators need to monitor process values, acknowledge alarms, and adjust setpoints without requiring a full graphical touchscreen interface.

    Technical Specifications

    Display Type STN monochrome LCD
    Display Size 4-line text display
    Input/Operating Voltage 24 V DC
    Power Consumption 4 W (typical)
    Communication Interface MPI, PROFIBUS DP
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Certifications CE, UL, cULus

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP 77B and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the configuration in WinCC flexible. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the configured PLC has been lost during operation.
    Inspect the communication cable for damage or loose connectors. Verify bus termination and cable shielding. Restart both the panel and the PLC if the connection does not recover automatically.
    Event ID: 20000
    Configuration or project data on the panel is missing or corrupted.
    Re-transfer the project from the WinCC flexible engineering station to the OP 77B. Ensure the transfer was completed successfully and the correct project version is used.
    Event ID: 40000
    Alarm buffer overflow. The number of pending alarms has exceeded the buffer capacity of the panel.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers or increase acknowledgement frequency.
    Event ID: 50000
    System startup error. The panel encountered a fault during the boot sequence.
    Perform a power cycle on the panel. If the error persists, re-transfer the project configuration. Check the supply voltage is stable at 24 V DC.
    Event ID: 60000
    Firmware version mismatch between the panel and the loaded project configuration.
    Update the panel firmware to the version required by the WinCC flexible project, or re-configure the project using a compatible WinCC flexible version and re-transfer.
    Event ID: 70000
    Tag or variable update error. One or more configured tags cannot be read from or written to the PLC.
    Verify the PLC data block addresses and variable types match those configured in the WinCC flexible project. Check that the PLC program is running and the relevant data areas are accessible.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7BE0)?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol depending on configuration.

    What software is required to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2005 or a later compatible version. Projects are transferred to the panel via the MPI interface or a PC adapter cable.

    What is the supply voltage for the 6AV6355-1CA47-7BE0?

    The panel requires a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to avoid operational faults.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for standard industrial cabinet installations.

    Can the OP 77B display graphical content or only text?

    The OP 77B is primarily a text-based operator panel with a 4-line monochrome display. It supports basic bar graphs and simple graphical elements but is not designed for full bitmap graphics or complex visualizations.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel's power connector. Check for blown fuses in the supply circuit and verify the power connector is fully seated.

    Restore the 24 V DC supply to within specification. Replace any blown fuses in the supply line. If the display remains blank with correct voltage, the internal power supply or display unit may require replacement.

    Panel shows communication error and cannot connect to PLC

    Inspect the MPI or PROFIBUS DP cable for physical damage, loose connectors, or missing bus termination resistors at both ends of the bus segment. Verify the panel's configured PLC address matches the actual PLC address.

    Replace or reseat the communication cable. Install correct bus termination resistors at both ends of the bus. Correct the PLC address in the WinCC flexible project and re-transfer the configuration to the panel.

    Project transfer from WinCC flexible fails or times out

    Check the PC adapter cable connection between the engineering PC and the panel's MPI port. Verify the correct COM port and transfer speed are selected in WinCC flexible. Confirm the panel is in transfer mode.

    Place the panel in transfer mode via the panel's start menu. Select the correct COM port and set the transfer rate to 187.5 kbps or as required. Replace the PC adapter cable if communication cannot be established.

    Alarms are not displayed or acknowledged on the panel

    Verify that the alarm tags in the WinCC flexible project are correctly mapped to the corresponding PLC bit addresses. Check that the PLC program is setting the alarm bits as expected during fault conditions.

    Correct the tag address mapping in the WinCC flexible project and re-transfer to the panel. Confirm the PLC logic is activating the correct alarm bits. Test alarm display by manually setting the alarm bits from the PLC programming software.

    Panel reboots unexpectedly during operation

    Monitor the 24 V DC supply voltage for dips or instability, particularly during machine start-up when inrush currents may cause voltage drops. Check for loose connections at the power terminal.

    Install a dedicated, regulated 24 V DC power supply with sufficient current capacity for the panel. Secure all power terminal connections and add surge protection if the supply environment is electrically noisy.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart