• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7BD6 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7BD6 OP 177B

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6355-1CA47-7BD6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7BD6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with keypad-based operation and is part of the Multi Panel and Operator Panel family developed by Siemens for industrial process visualization. The OP 177B is engineered to interface with Siemens SIMATIC PLCs and third-party controllers in demanding industrial environments.

    The 6AV6355-1CA47-7BD6 features a 5.7-inch STN display with a resolution of 320 x 240 pixels and supports both MPI/PROFIBUS DP and Ethernet communication interfaces, enabling flexible integration into existing automation networks. The panel runs on WinCC flexible runtime software and supports configuration via WinCC flexible engineering software on a PC. It includes function keys, system keys, and a numeric/alphanumeric keypad for operator input, and is rated IP65 on the front face for protection against dust and water ingress. The unit operates on 24 V DC supply and is built to withstand the vibration and temperature conditions typical of industrial machinery.

    The OP 177B is widely deployed in manufacturing, automotive, food and beverage, and process industries where reliable operator control and monitoring at the machine level is required. It is commonly used on standalone machines, production lines, and packaging equipment where a compact, robust HMI with keypad operation is preferred over a pure touchscreen solution. Its compatibility with the SIMATIC S7 controller family makes it a standard choice for Siemens-based automation architectures.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 12 W
    Communication Interface MPI/PROFIBUS DP, Ethernet (RJ45), RS-422/RS-485
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP 177B
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2008 or later

    Common Error Codes and System Events

    Event ID: 10000
    Connection to the PLC has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP or Ethernet cable connections, verify PLC address settings, and confirm the PLC is powered and in RUN mode.
    Event ID: 10001
    Communication timeout with the configured controller.
    Verify the communication parameters (baud rate, station address) in WinCC flexible match the PLC configuration. Check for cable faults or network conflicts.
    Event ID: 20000
    Project download error — project data could not be transferred to the panel.
    Ensure the correct transfer cable or Ethernet connection is used, check that the panel is in transfer mode, and verify WinCC flexible project compatibility with the panel firmware version.
    Event ID: 40000
    Internal device error — panel hardware fault detected.
    Perform a panel reset. If the error persists, check the 24 V DC supply voltage and inspect for hardware damage. A firmware update or panel replacement may be required.
    Event ID: 50000
    Backup battery low or missing (if applicable).
    Replace the internal backup battery with the correct Siemens-approved replacement to prevent loss of retentive data and real-time clock settings.
    Event ID: 70000
    Firmware update failed or firmware version mismatch detected.
    Re-flash the panel firmware using ProSave or WinCC flexible, ensuring the firmware version is compatible with the installed project and hardware revision.
    Event ID: 30000
    Tag or variable address not accessible — the configured PLC address cannot be read or written.
    Verify the tag addresses in the WinCC flexible project match the actual PLC data block or memory area. Check PLC program for address changes.

    Frequently Asked Questions

    What communication interfaces does the OP 177B (6AV6355-1CA47-7BD6) support?

    The OP 177B supports MPI/PROFIBUS DP and Ethernet (RJ45) interfaces, as well as RS-422/RS-485 serial communication, allowing connection to SIMATIC S7 PLCs and a range of third-party controllers.

    Which configuration software is required to program this panel?

    The panel is configured using Siemens WinCC flexible 2008 or a compatible later version. Projects are transferred to the panel via Ethernet or a PC/MPI adapter cable.

    Is the OP 177B compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the OP 177B is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and can also communicate with S7-200 and third-party controllers via the appropriate protocol drivers.

    What is the front panel protection rating of this unit?

    The front panel of the OP 177B is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets, making it suitable for installation in industrial control panels.

    Can this panel be used as a direct replacement for older OP 170B units?

    The OP 177B is the successor to the OP 170B and is largely compatible in terms of panel cutout dimensions and functionality, though project migration using WinCC flexible may be required to adapt existing configurations.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel's power connector. Check for blown fuses in the control cabinet supply circuit. Verify the power supply polarity is correct.

    Restore the 24 V DC supply to within the specified tolerance. Replace any blown fuses. If the supply is correct and the display remains blank, the internal power supply board or backlight may be faulty and require replacement.

    Panel displays 'No connection to PLC' or communication error on startup

    Check the MPI/PROFIBUS DP or Ethernet cable for physical damage. Verify the station address and baud rate configured in WinCC flexible match the PLC settings. Confirm the PLC is powered and in RUN or STOP mode.

    Correct any mismatched communication parameters in the WinCC flexible project and re-download. Replace damaged cables. Ensure the network termination resistors are correctly set on the PROFIBUS segment if applicable.

    Touchscreen or keypad inputs are not responding correctly

    For keypad issues, inspect the keypad membrane for physical damage or contamination. Test each key in the panel's service menu if accessible. Check for any project configuration errors that may have disabled input areas.

    Clean the keypad surface with a dry cloth. If individual keys are unresponsive, the keypad membrane assembly may need replacement. Re-download the WinCC flexible project to rule out software configuration issues.

    Panel repeatedly resets or reboots during operation

    Monitor the 24 V DC supply voltage for dips or instability under load. Check the operating ambient temperature around the panel. Inspect the project for memory overload or runtime errors in the WinCC flexible diagnostics log.

    Stabilize the power supply by using a dedicated 24 V DC rail or adding capacitance. Ensure adequate ventilation around the panel. Optimize the WinCC flexible project to reduce memory usage, or update the panel firmware to the latest version.

    Project download fails or panel does not enter transfer mode

    Verify the Ethernet or MPI cable connection between the PC and the panel. Confirm the panel is set to transfer mode via the Start Center or loader menu. Check that the WinCC flexible version is compatible with the panel firmware.

    Manually set the panel to transfer mode by accessing the loader/Start Center at boot. Use ProSave to update the firmware if a version mismatch is detected. Try an alternative transfer cable or Ethernet port if the connection is not recognized.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart