Siemens 6AV6355-1CA47-7BD4 OP 177B
The Siemens 6AV6355-1CA47-7BD4 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with touch and key-based operation, functioning as a compact operator panel for process visualization and control. It is part of Siemens' established SIMATIC HMI product line, offering reliable panel-based interaction for industrial automation environments.
The OP 177B features a 5.7-inch STN display and supports both MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7 PLCs. The panel includes configurable function keys, an integrated numeric/alphanumeric keypad, and supports WinCC flexible as its configuration software. It offers a USB interface for project transfer and data backup, along with an Ethernet port on select variants, and operates on a 24 V DC supply. Onboard flash memory supports project storage and recipe management.
The OP 177B is widely deployed in machine building, packaging, food and beverage processing, and general manufacturing automation. Its compact form factor and robust keypad interface make it suitable for environments where touchscreen-only operation is impractical, such as applications requiring gloved-hand operation or high-cycle key inputs. The panel's compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a standard choice for mid-range machine control panels.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN LCD |
| Display Colors | 256 colors |
| Resolution | 320 x 240 pixels (QVGA) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | MPI, PROFIBUS DP, USB, Ethernet |
| Configuration Software | WinCC flexible 2005 or higher |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during startup; the loaded project is incompatible or corrupted.
Reload the project using WinCC flexible via USB or Ethernet. Verify project compatibility with the panel firmware version. - Event ID: 20000
- Communication error on MPI or PROFIBUS DP interface; connection to the PLC has been lost.
Check MPI/PROFIBUS cable connections and termination resistors. Verify bus address settings on both the panel and the PLC. - Event ID: 40000
- Tag read/write error; the panel cannot access a configured PLC data address.
Verify the PLC program contains the referenced data blocks and addresses. Check that the PLC is in RUN mode. - Event ID: 50000
- Recipe data error; recipe records cannot be read from or written to internal memory.
Check available flash memory capacity. Re-transfer the project and verify recipe configuration in WinCC flexible. - Event ID: 60000
- Firmware update error; the firmware transfer was interrupted or the file is invalid.
Restart the panel in transfer mode and retry the firmware update using a valid firmware package from Siemens support. - Event ID: 70000
- Backup/restore error; project or data backup via USB could not be completed.
Check the USB storage device for compatibility and available space. Reformat the USB device if necessary and retry the operation. - Event ID: 80000
- Screen saver or display fault; display fails to respond or remains blank after activation.
Check the 24 V DC supply voltage at the panel connector. Verify the screen saver timeout settings in the project configuration.
Frequently Asked Questions
What communication interfaces are available on the 6AV6355-1CA47-7BD4?
The OP 177B supports MPI and PROFIBUS DP for PLC communication, along with a USB interface for project transfer and an Ethernet port for network connectivity.
Which configuration software is required for this panel?
The panel is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via USB or Ethernet.
Is the OP 177B compatible with SIMATIC S7-300 and S7-400 PLCs?
Yes, the OP 177B is fully compatible with SIMATIC S7-300 and S7-400 controllers via MPI or PROFIBUS DP interfaces.
What is the front panel protection rating of this unit?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments with dust and water spray exposure.
Can the OP 177B be operated with gloves?
Yes, the OP 177B includes a physical membrane keypad in addition to its display, allowing reliable operation with gloves where touchscreen use is not practical.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel's power connector. Check for blown internal fuses or wiring faults at the terminal block.
Restore correct 24 V DC supply within the specified tolerance. If the supply is correct and the display remains blank, the backlight or internal power board may require replacement.
Panel fails to communicate with the PLC via PROFIBUS DP
Check the PROFIBUS cable for continuity and correct termination at both ends of the bus. Verify the panel's PROFIBUS address does not conflict with other devices on the network.
Correct any address conflicts, replace damaged cables, and ensure bus termination resistors are enabled only at the physical ends of the PROFIBUS segment.
Project transfer via USB fails or is not recognized
Check that the USB storage device is formatted as FAT32 and that the project file was exported correctly from WinCC flexible. Verify the panel is in Transfer mode.
Reformat the USB device as FAT32, re-export the project from WinCC flexible, and switch the panel to Transfer mode before initiating the transfer.
Touchscreen or function keys are unresponsive
Inspect the panel for physical damage to the keypad membrane or display surface. Check if the panel is in a locked or screensaver state.
Perform a panel restart by cycling the 24 V DC power. If keys remain unresponsive after restart, the keypad membrane assembly may need to be replaced.
Panel repeatedly reboots or shows startup errors
Check the project loaded on the panel for compatibility with the installed firmware version. Inspect the flash memory for corruption by attempting a project reload.
Update the panel firmware to the version compatible with the WinCC flexible project, then re-transfer the project. If rebooting persists, perform a factory reset via the panel's Start Center menu.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page