• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7BC1 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7BC1 OP 177B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7BC1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7BC1 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with touch and key-based operation, serving as a compact yet capable panel for process visualization and control. It is part of Siemens' established SIMATIC HMI portfolio, offering reliable performance in demanding industrial environments.

    The OP 177B (6AV6355-1CA47-7BC1) features a 5.7-inch STN display and supports both MPI/PROFIBUS DP and Ethernet communication interfaces, enabling flexible integration into existing Siemens automation architectures. The panel runs WinCC flexible runtime software and includes onboard flash memory for project storage. It supports configuration via SIMATIC WinCC flexible engineering software and offers a robust membrane keypad with function keys for operator input alongside the touchscreen.

    The OP 177B is widely deployed in manufacturing, packaging, and process industries where a compact, panel-mount HMI is required for machine control and status monitoring. Its compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs makes it a versatile choice for both new installations and retrofit projects. The unit is suited for applications requiring reliable local operator interaction in environments with moderate space constraints and standard industrial conditions.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Display Resolution 320 x 240 px (QVGA)
    Touch Technology Resistive touchscreen with membrane keypad
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI/PROFIBUS DP, Ethernet (RJ45), RS-422/RS-485
    Memory 4 MB flash (user memory)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected during startup; the loaded project is incompatible or corrupt.
    Reload the project using WinCC flexible. Verify the project was compiled for the correct HMI device type and firmware version.
    Event ID: 20000
    Communication error on MPI/PROFIBUS DP interface; connection to the PLC has been lost.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify the bus address settings on both the HMI and PLC match the project configuration.
    Event ID: 40000
    Tag read/write error; the HMI cannot access a configured PLC tag.
    Verify the PLC is in RUN mode and the tag address in the WinCC flexible project is correct. Check communication link status.
    Event ID: 50000
    Alarm buffer overflow; the number of pending alarms has exceeded the buffer capacity.
    Acknowledge and clear active alarms. Review alarm configuration to reduce simultaneous alarm occurrences or increase buffer size in the project settings.
    Event ID: 60000
    Internal device error; a system fault has been detected in the HMI panel firmware.
    Perform a power cycle. If the error persists, update the firmware using ProSave or WinCC flexible and consider restoring factory settings.
    Event ID: 70000
    Recipe data error; recipe records could not be read from or written to flash memory.
    Check available flash memory capacity. Re-transfer the project and recipe data. If flash memory is suspected faulty, the panel may require servicing.
    Event ID: 80000
    Ethernet communication error; connection to a network node has failed or timed out.
    Verify Ethernet cable integrity and switch/hub connectivity. Confirm IP address settings in the project match the physical network configuration.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6355-1CA47-7BC1)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports connectivity to S7 controllers via Ethernet using the integrated RJ45 port.

    What software is used to configure and program this HMI panel?

    The OP 177B is configured using Siemens SIMATIC WinCC flexible (Compact or Standard edition). Projects are transferred to the panel via MPI, PROFIBUS, Ethernet, or USB using the ProSave utility.

    What is the supply voltage for the 6AV6355-1CA47-7BC1?

    The panel operates on 24 V DC. The power supply must be capable of delivering sufficient current to meet the panel's maximum power consumption of approximately 9 W.

    Does this panel support recipe and alarm management functions?

    Yes, the OP 177B supports recipe management, alarm logging, and trend display functions within the WinCC flexible runtime environment, subject to available flash memory capacity.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B carries an IP65 protection rating, making it suitable for panel-mount installations where dust and water spray resistance is required.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector. Check that the supply is within tolerance and that the connector is fully seated. Inspect for any blown internal fuse.

    Correct the supply voltage if out of range. Re-seat the power connector. If the display backlight has failed, the panel will require backlight or display module replacement.

    HMI panel fails to communicate with the PLC via PROFIBUS DP

    Check the PROFIBUS cable for continuity and correct termination at both ends of the bus. Verify the bus address configured on the HMI matches the project settings and that no address conflicts exist.

    Replace or re-terminate the PROFIBUS cable as needed. Correct the bus address in WinCC flexible and re-transfer the project. Ensure the PLC is in RUN mode and the PROFIBUS network is properly terminated.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt to recalibrate the touchscreen through the panel's Control Panel settings in the Start Center. Check for physical damage or contamination on the screen surface.

    Perform a touchscreen calibration via the SIMATIC HMI Start Center. Clean the screen surface with a soft, dry cloth. If calibration does not resolve the issue, the touchscreen overlay may require replacement.

    Project transfer fails when attempting to download via Ethernet

    Verify the IP address assigned to the HMI panel in the Start Center matches the target address configured in WinCC flexible. Check that the PC and HMI are on the same network subnet and that no firewall is blocking the transfer port.

    Correct the IP address settings on the panel or in the project. Disable any PC firewall temporarily during transfer. Ensure the Ethernet cable is functional and the network switch port is active.

    Panel repeatedly restarts or displays a runtime error on startup

    The loaded project may be corrupt or incompatible with the current firmware version. Connect via ProSave and check the firmware version installed on the device.

    Update the panel firmware to the version compatible with the WinCC flexible project. Re-transfer the project after firmware update. If the issue persists, perform a factory reset via ProSave and reload the project from scratch.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart