• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7HC6 OP 177B
    Awaiting product image

    Siemens 6AV6355-1AA47-7HC6 OP 177B

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6355-1AA47-7HC6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7HC6 is an operator panel belonging to the SIMATIC HMI OP 177B series, designed for machine-level human-machine interface applications. This unit is part of Siemens' established SIMATIC HMI product line and provides a compact, panel-mounted interface for process visualization and control. The OP 177B series bridges the gap between basic text-based panels and full graphical HMI systems, offering a monochrome or color display depending on the variant.

    The 6AV6355-1AA47-7HC6 features a 5.7-inch STN display with touch and key-based operation, supporting both MPI and PROFIBUS DP communication interfaces for direct integration with SIMATIC S7 PLCs. The panel includes an integrated configuration memory and supports WinCC flexible as its engineering software platform. It operates on a 24 V DC supply and is built to withstand industrial environments, carrying a front-panel protection rating of IP65. The unit supports recipe management, alarm logging, and trend display functions.

    The OP 177B is widely deployed in manufacturing, packaging, and process automation environments where a reliable and compact operator interface is required at the machine level. It is commonly found on standalone machines, conveyor systems, and small-to-medium automation cells where direct PLC communication via MPI or PROFIBUS is standard practice. Its robust construction and compatibility with the SIMATIC S7 controller family make it a practical choice for both OEM machine builders and end-user installations.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Touch Technology Touch screen with membrane keypad
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP, RS 422/485
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Engineering Software WinCC flexible 2005 or higher
    Series/Product Family SIMATIC HMI OP 177B
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Confirm station address settings match the project configuration.
    Event ID: 10001
    Connection to PLC interrupted during runtime operation.
    Inspect communication cable for damage. Check bus termination and cable shielding. Restart the HMI panel and verify PLC program is active.
    Event ID: 20000
    Project download failed or project data on the panel is corrupted or missing.
    Re-download the project from WinCC flexible to the panel via MPI or USB/serial transfer cable. Verify project compatibility with the panel firmware version.
    Event ID: 40000
    Internal device error or hardware fault detected on the panel.
    Perform a panel reset. If the fault persists, check the 24 V DC supply voltage and inspect internal components. Contact Siemens technical support or arrange for unit repair.
    Event ID: 50000
    Firmware version mismatch between the panel and the downloaded project.
    Update the panel firmware using ProSave or WinCC flexible to match the version required by the project. Re-download the project after firmware update.
    Event ID: 60000
    Tag or variable address not accessible. The HMI cannot read or write the configured PLC tag address.
    Verify the PLC tag addresses in the WinCC flexible project match the actual PLC data block or memory addresses. Check PLC program for address changes.
    Event ID: 70000
    Alarm buffer overflow. The number of pending alarms exceeds the panel's alarm buffer capacity.
    Acknowledge and clear active alarms. Review the alarm configuration in WinCC flexible and consider increasing the alarm buffer size or reducing alarm frequency in the PLC program.

    Frequently Asked Questions

    What communication interfaces does the OP 177B (6AV6355-1AA47-7HC6) support?

    The OP 177B supports MPI and PROFIBUS DP communication interfaces, as well as RS 422/485 serial communication. This allows direct connection to SIMATIC S7-300 and S7-400 PLCs without additional hardware.

    Which engineering software is required to configure this panel?

    The panel is configured using Siemens WinCC flexible 2005 or a later compatible version. Projects are downloaded to the panel via MPI connection or a PC/PPI adapter cable.

    Is the OP 177B compatible with SIMATIC S7-1200 or S7-1500 PLCs?

    The OP 177B was designed primarily for use with S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. Compatibility with S7-1200 and S7-1500 is limited and generally not recommended; TIA Portal-based panels are the preferred choice for those controllers.

    What is the front panel protection rating of this unit?

    The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    What supply voltage does the 6AV6355-1AA47-7HC6 require?

    The panel operates on a 24 V DC supply voltage. Ensure a stable, regulated 24 V DC power source is used to avoid display or communication issues.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check for blown internal fuses or wiring faults on the supply lines.

    Ensure the supply voltage is within the specified 24 V DC range. Replace any blown fuses and verify correct polarity of the power connection. If the backlight has failed, the display unit or backlight inverter may require replacement.

    Panel displays 'No connection to PLC' or communication error at startup

    Check the MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination resistors are correctly placed at both ends of the bus segment.

    Re-seat all communication connectors, confirm correct bus address settings on both the panel and PLC, and ensure termination resistors are enabled only at the physical ends of the bus. Restart both the panel and PLC after corrections.

    Touchscreen does not respond or responds inaccurately to input

    Attempt to recalibrate the touchscreen through the panel's startup menu or control panel settings. Check for physical damage or contamination on the touch surface.

    Perform a touchscreen calibration using the built-in calibration routine accessible during panel startup. Clean the touch surface with a soft, dry cloth. If calibration fails repeatedly, the touch overlay may require replacement.

    Project fails to download from WinCC flexible to the panel

    Verify the PC-to-panel communication cable is correctly connected and the correct COM port or MPI adapter is selected in WinCC flexible transfer settings. Check that the panel is in transfer mode.

    Place the panel in transfer mode via the startup menu, select the correct interface and baud rate in WinCC flexible, and retry the download. Ensure the WinCC flexible project version is compatible with the panel's installed firmware version.

    Panel reboots repeatedly or freezes during operation

    Check the 24 V DC supply for voltage drops or ripple that may cause instability. Inspect the panel for signs of overheating or excessive ambient temperature.

    Stabilize the power supply and ensure adequate ventilation around the panel. If the issue persists, perform a factory reset and re-download the project. Persistent faults may indicate a failing internal power supply or memory component requiring hardware repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart