• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7HB0 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7HB0 OP 77A

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7HB0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7HB0 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling automation processes. This unit is part of the SIMATIC HMI product line, which integrates tightly with Siemens SIMATIC S7 and S5 PLC families.

    The OP 77A features a monochrome LCD display with a fixed number of function keys and system keys for navigation and data entry, eliminating the need for a touchscreen while maintaining robust operability in industrial environments. It supports MPI and PROFIBUS DP communication interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 controllers. The panel is configured using Siemens ProTool or WinCC flexible engineering software, and offers recipe management, alarm logging, and message display capabilities within its onboard memory.

    The OP 77A is typically deployed in manufacturing, automotive, food and beverage, and packaging industries where a reliable, cost-effective operator interface is required at the machine level. Its compact form factor and keypad-based operation make it well suited for control cabinets and machine panels where space is limited and touchscreen operation is not practical. The panel's compatibility with the SIMATIC ecosystem makes it a common choice for retrofitting older S5-based installations or integrating into new S7-based systems.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 5 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP 77A
    Certifications CE, UL
    Configuration Software ProTool, WinCC flexible

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the panel configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    PLC is not responding or connection has been lost during operation.
    Check physical wiring and bus termination. Verify PLC is powered and operational. Restart the panel and attempt reconnection.
    Event ID: 20000
    Configuration or project download error. The project loaded on the panel is incompatible or corrupted.
    Re-download the project from ProTool or WinCC flexible to the panel. Verify the project was compiled without errors before transfer.
    Event ID: 40000
    Internal memory error detected on the panel.
    Perform a panel reset and re-download the project. If the error persists, the internal memory may be faulty and the panel should be repaired or replaced.
    Event ID: 50000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration in the project to reduce unnecessary alarm triggers.
    Event ID: 60000
    Incorrect operating voltage detected. Supply voltage is outside the permissible range.
    Measure the 24 V DC supply at the panel power connector. Ensure the supply is within the specified tolerance and check for loose connections or power supply faults.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A (6AV6355-1AA47-7HB0)?

    The OP 77A is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports connection to SIMATIC S5 controllers through appropriate protocol converters.

    What software is used to configure and program the OP 77A?

    The OP 77A is configured using Siemens ProTool or WinCC flexible engineering software. Projects are compiled and downloaded to the panel via the MPI interface or a serial programming cable.

    What is the supply voltage for the 6AV6355-1AA47-7HB0?

    The panel operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance to avoid operational faults.

    What is the IP protection rating of the OP 77A front panel?

    The front panel of the OP 77A carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for typical industrial cabinet installations.

    Does the OP 77A support recipe management and alarm logging?

    Yes, the OP 77A supports recipe management and alarm/message logging within its onboard memory, allowing operators to store process parameters and review historical alarm events directly on the panel.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify that the supply is within the permissible range and that all connectors are securely seated.

    Restore correct 24 V DC supply voltage. If voltage is correct and display remains blank, the internal power supply or display backlight may be faulty and the panel should be sent for repair.

    Panel shows communication error and cannot connect to PLC

    Inspect the MPI or PROFIBUS DP cable for physical damage, loose connectors, and correct bus termination at both ends of the network. Verify the PLC address and baud rate settings match those configured in the panel project.

    Replace or reseat the communication cable, correct bus termination, and ensure PLC address settings are consistent between the panel project and the PLC configuration. Re-download the project if settings were changed.

    Panel repeatedly restarts or resets unexpectedly

    Check the 24 V DC supply for voltage dips or instability using an oscilloscope or data logger. Inspect the power supply unit feeding the panel for faults or overload conditions.

    Stabilize the power supply or replace the power supply unit if it is producing unstable output. Ensure no other high-inrush loads are sharing the same supply rail as the panel.

    Project download fails or panel does not accept new configuration

    Verify that the correct version of ProTool or WinCC flexible is being used and that the project was compiled without errors. Check the programming cable connection and the MPI interface settings on both the PC and the panel.

    Recompile the project in the engineering software, ensure the correct panel type is selected, and retry the download. If the download still fails, perform a factory reset on the panel before attempting again.

    Function keys or system keys do not respond

    Check for physical damage or contamination on the keypad membrane. Attempt to navigate the panel menu using different keys to isolate whether the fault is with specific keys or the entire keypad.

    Clean the keypad surface if contamination is present. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly should be replaced by a qualified repair technician.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart