• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7ES2 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7ES2 OP 77A

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7ES2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7ES2 is an operator panel belonging to the SIMATIC HMI OP 77A series, designed for human-machine interface applications in industrial automation environments. This compact panel provides a keypad-based interface for monitoring and controlling machine processes, and is part of Siemens' established SIMATIC HMI product line. It is intended for use with Siemens SIMATIC S7 PLCs and other compatible controllers via standard communication interfaces.

    The OP 77A features a monochrome LCD display and a membrane keypad for operator input, offering a robust and reliable interface without a touchscreen. It supports MPI and PROFIBUS DP communication protocols, enabling direct integration into Siemens automation networks. The panel is configured using WinCC flexible software, allowing engineers to create and download project data for process visualization and operator control. Its compact housing and low power consumption make it suitable for panel-mounting in space-constrained installations.

    The SIMATIC OP 77A is widely used in manufacturing, packaging, and process automation applications where a cost-effective, durable operator interface is required. It is commonly found on standalone machines, conveyor systems, and small to medium automation cells where basic process monitoring and parameter adjustment are needed. The panel's compatibility with the SIMATIC S7 controller family makes it a practical choice for system integrators working within established Siemens automation architectures.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4 W
    Communication Interface MPI, PROFIBUS DP
    Configuration Software WinCC flexible 2005 or higher
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC HMI OP 77A

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication timeout on MPI/PROFIBUS interface.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify PLC is powered and running. Check configured station address matches the PLC.
    Event ID: 10001
    No project loaded on the operator panel.
    Use WinCC flexible to compile and download a valid project to the OP 77A. Ensure the transfer connection is correctly configured.
    Event ID: 20000
    Tag read error — the panel cannot read a configured PLC data tag.
    Verify the tag address in WinCC flexible matches the actual PLC memory address. Check PLC program for correct data block or variable definition.
    Event ID: 20001
    Tag write error — the panel cannot write a value to the configured PLC tag.
    Check that the PLC tag is not write-protected. Verify address configuration in WinCC flexible and confirm PLC is in RUN mode.
    Event ID: 40000
    System memory low — internal panel memory is insufficient for current project.
    Reduce project size by removing unused screens, tags, or graphics. Recompile and re-download the project using WinCC flexible.
    Event ID: 50000
    Transfer mode active — panel is waiting for project download.
    Initiate project transfer from WinCC flexible on the engineering PC, or press ESC on the panel keypad to cancel transfer mode and return to runtime.
    Event ID: 60000
    Operating system or firmware version mismatch detected.
    Update the panel firmware using the Siemens ProSave tool to match the version required by the WinCC flexible project.

    Frequently Asked Questions

    Which communication protocols does the OP 77A support?

    The OP 77A supports MPI and PROFIBUS DP communication protocols, allowing direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs.

    What software is required to configure the Siemens 6AV6355-1AA47-7ES2?

    The panel is configured using Siemens WinCC flexible 2005 or a later compatible version. Projects are compiled and downloaded to the panel via the MPI or PROFIBUS interface.

    What is the supply voltage for this operator panel?

    The OP 77A requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid damage or erratic operation.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Can the OP 77A be used with non-Siemens PLCs?

    The OP 77A is primarily designed for use with Siemens SIMATIC S7 PLCs via MPI or PROFIBUS DP. Connectivity to third-party controllers is not natively supported by this panel.

    Troubleshooting

    Display remains blank after power is applied

    Measure 24 V DC at the power supply terminals on the rear of the panel. Check the supply cable and connector for damage or loose connections.

    Restore correct 24 V DC supply. If supply voltage is confirmed correct and the display remains blank, the internal power supply or LCD backlight may have failed and the unit should be sent for repair or replacement.

    Panel shows 'Connecting…' and fails to establish communication with the PLC

    Check the MPI or PROFIBUS DP cable between the panel and PLC. Verify bus termination is correctly applied at both ends of the network. Confirm the station address configured on the panel matches the PLC address.

    Replace or reseat the communication cable. Correct the station address in the panel settings or WinCC flexible project. Ensure only the two physical end nodes have bus termination resistors enabled.

    Panel enters transfer mode unexpectedly on startup

    The panel may have been configured to start in transfer mode, or the transfer mode button combination was activated unintentionally during boot.

    Allow the transfer to time out or press ESC to exit transfer mode. In WinCC flexible, configure the panel startup behavior to launch the runtime project directly rather than entering transfer mode.

    Operator inputs via keypad are not responding or are erratic

    Inspect the membrane keypad for physical damage, contamination, or worn key surfaces. Check that the project configuration correctly maps keypad functions to the intended actions.

    Clean the keypad surface with a dry cloth. If keys remain unresponsive, the membrane keypad assembly may need replacement. Verify key assignments in the WinCC flexible project and re-download if necessary.

    Project download fails during transfer from WinCC flexible

    Check the MPI cable connection between the engineering PC and the panel. Verify the correct COM port or PC adapter is selected in WinCC flexible transfer settings. Confirm the panel is in transfer mode.

    Reseat the MPI cable and select the correct interface in WinCC flexible. Ensure the PC adapter driver is correctly installed. If using a USB-MPI adapter, verify driver compatibility with the operating system version.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart