• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7CM1 OP 177B
    Awaiting product image

    Siemens 6AV6355-1AA47-7CM1 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7CM1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7CM1 is an operator panel belonging to the SIMATIC HMI OP 177B series, manufactured by Siemens. This unit is a compact, panel-mounted human-machine interface designed for machine-level visualization and operator control tasks. It belongs to the SIMATIC HMI family and is intended for use with Siemens SIMATIC S7 and other compatible PLC platforms.

    The OP 177B features a 5.7-inch STN display with a resolution of 320 x 240 pixels and supports both color and monochrome display variants. It provides communication via MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, enabling direct integration into Siemens automation networks. The panel includes configurable function keys, a membrane keypad, and is configured using WinCC flexible engineering software. It supports recipe management, trend display, alarm logging, and user administration functions.

    The OP 177B is widely deployed in manufacturing automation, machine tool control, packaging machinery, and process plant environments. Its robust construction and compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs make it suitable for demanding industrial settings where reliable operator interaction is required. The panel is typically mounted in control cabinet doors or machine panels and is suited for applications requiring a cost-effective yet capable HMI solution.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels
    Display Type STN LCD
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 10 W
    Communication Interface MPI, PROFIBUS DP, RS-422/RS-485
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Engineering Software WinCC flexible 2005 or higher
    Certifications CE, UL, cULus

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. Connection to the configured controller cannot be established or has been lost.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Restart both PLC and HMI panel.
    Event ID: 10001
    Connection to PLC interrupted during operation. The HMI panel has lost communication with the controller.
    Inspect communication cables for damage. Verify bus termination and cable shielding. Check PLC operating state and confirm it is in RUN mode.
    Event ID: 20000
    Tag read error. The HMI panel cannot read a configured tag from the PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for correct data area allocation.
    Event ID: 20001
    Tag write error. The HMI panel cannot write a value to the configured PLC tag.
    Check that the target PLC memory area is not write-protected. Verify tag address configuration in WinCC flexible and confirm PLC is in RUN mode.
    Event ID: 40000
    Project download error. Transfer of the HMI project from the engineering PC to the panel has failed.
    Ensure the panel is in Transfer mode before initiating download. Check the communication cable between PC and panel. Verify WinCC flexible project is compiled without errors.
    Event ID: 50000
    Internal device error. A hardware or firmware fault has been detected within the HMI panel.
    Perform a panel restart. If the error persists, perform a factory reset via the panel loader menu. If the fault continues, the unit may require hardware repair or replacement.
    Event ID: 60000
    Insufficient memory. The HMI panel does not have enough free memory to load or run the configured project.
    Reduce the project size by optimizing graphics, recipes, or alarm lists. Perform a complete panel reset and reload the project. Check for memory fragmentation by restarting the panel.

    Frequently Asked Questions

    Which engineering software is required to configure the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2005 or later versions. Projects are transferred to the panel via MPI, PROFIBUS DP, or a direct serial connection from the engineering PC.

    Which Siemens PLCs are compatible with the OP 177B?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as SIMATIC 505 and certain third-party controllers via configurable communication drivers in WinCC flexible.

    What communication interfaces does the 6AV6355-1AA47-7CM1 support?

    This panel supports MPI and PROFIBUS DP communication, as well as RS-422 and RS-485 serial interfaces. These allow direct connection to Siemens PLCs and other compatible automation controllers.

    What is the supply voltage for the OP 177B?

    The OP 177B requires a 24 V DC power supply. The permissible voltage range is typically 19.2 V DC to 28.8 V DC, and the power consumption is a maximum of 10 W.

    Can the OP 177B be used as a replacement for an OP 170B?

    The OP 177B is the successor to the OP 170B and is largely compatible in terms of form factor and functionality. Existing WinCC flexible projects may require minor adaptation, but the panel cutout dimensions are compatible for direct replacement.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that the voltage is within the 19.2 V to 28.8 V DC range. Inspect the internal fuse if accessible.

    Correct the supply voltage if out of range. Replace the power supply unit feeding the panel if voltage is absent. If supply voltage is correct and display remains blank, the internal power supply board or backlight inverter may require replacement.

    HMI panel fails to establish communication with the PLC

    Verify the MPI or PROFIBUS DP address configured in the WinCC flexible project matches the address set on the PLC. Check bus cable connections, termination resistors at both ends of the bus, and cable shielding continuity.

    Correct any address mismatches in the project configuration. Replace damaged bus cables and ensure proper bus termination is installed. Confirm the PLC is powered and in RUN mode before retrying communication.

    Touchscreen or function keys are unresponsive

    Check whether the panel is in Transfer mode, which disables normal operation. Attempt a panel restart. If keys are physically damaged, inspect the membrane keypad connector on the main board.

    Exit Transfer mode via the panel loader if active. Restart the panel to clear any software lock. If the membrane keypad is physically worn or damaged, replace the keypad assembly.

    Project download from PC to panel fails repeatedly

    Confirm the panel is set to Transfer mode before initiating the download. Check the communication cable between the PC and the panel for continuity. Verify that the correct communication port and transfer settings are selected in WinCC flexible.

    Switch the panel to Transfer mode via the Start Center menu. Use a known-good MPI or serial transfer cable. Recompile the WinCC flexible project and retry the transfer. If the issue persists, perform a factory reset on the panel and attempt the download again.

    Alarm messages are not displayed or are missing on the panel

    Check the alarm configuration in the WinCC flexible project to confirm alarm tags are correctly mapped to PLC addresses. Verify that the PLC is writing the expected bit or value to trigger the alarm.

    Correct any tag address mismatches in the alarm configuration. Ensure the PLC program is setting the alarm trigger bits as intended. Reload the corrected project to the panel and test alarm triggering from the PLC side.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart