Siemens 6AV6355-1AA47-7CJ1 OP 77A
The Siemens 6AV6355-1AA47-7CJ1 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling industrial processes. This unit is part of the SIMATIC HMI Basic Panels generation and is intended for use with Siemens SIMATIC S7 PLCs and other compatible controllers.
The OP 77A features a monochrome LCD display with a resolution of 128 x 64 pixels, offering clear text and simple graphic visualization. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration into Siemens automation networks. The panel is configured using WinCC flexible software and supports a defined number of tags, alarm messages, and recipe management functions. The housing is rated IP65 on the front face, providing protection against dust and water ingress in industrial environments.
The OP 77A is widely deployed in machine building, packaging, food and beverage, and general manufacturing industries where a cost-effective, reliable operator interface is required. Its compact form factor makes it suitable for integration into control cabinet doors and machine panels with limited space. The robust construction and compatibility with the SIMATIC ecosystem make it a practical choice for straightforward process monitoring and parameter adjustment tasks.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Resolution | 128 x 64 pixels |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 4.5 W (typical) |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible |
| Series/Product Family | SIMATIC HMI OP 77A |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Connection to PLC lost or communication timeout on MPI/PROFIBUS DP interface.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and in RUN mode. Check configured station address matches PLC settings. - Event ID: 10001
- No connection to configured controller at startup.
Verify communication parameters (baud rate, station address) in WinCC flexible project match the connected PLC configuration. Check physical wiring. - Event ID: 20000
- Tag read/write error — the panel cannot access a configured tag in the PLC.
Check that the tag address exists in the PLC program and that the data block or memory area is accessible. Verify the project configuration in WinCC flexible. - Event ID: 40000
- Project download error — project transfer to the panel was interrupted or failed.
Restart the transfer process. Ensure the correct communication interface and parameters are selected in WinCC flexible. Check cable integrity. - Event ID: 50000
- Internal device error — panel hardware or firmware fault detected.
Perform a panel reset. If the error persists, update the panel firmware via WinCC flexible. Contact Siemens support if the fault remains after firmware update. - Event ID: 60000
- Alarm buffer overflow — the number of pending alarms exceeds the panel buffer capacity.
Acknowledge and clear existing alarms. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers or increase acknowledgment frequency.
Frequently Asked Questions
What communication interfaces does the OP 77A support?
The OP 77A supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs as well as other PROFIBUS-compatible controllers.
What software is used to configure the Siemens 6AV6355-1AA47-7CJ1?
The panel is configured using Siemens WinCC flexible software. The project is then transferred to the panel via the MPI or PROFIBUS DP interface.
What is the supply voltage for this operator panel?
The OP 77A operates on a 24 V DC supply voltage.
What is the front panel protection rating of the OP 77A?
The front face of the OP 77A is rated IP65, providing protection against dust and low-pressure water jets, making it suitable for installation in industrial environments.
Can the OP 77A be used with non-Siemens PLCs?
The OP 77A is primarily designed for use with Siemens SIMATIC PLCs via MPI and PROFIBUS DP. Limited compatibility with third-party PROFIBUS DP controllers may be possible depending on the device profile supported.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Measure voltage under load to rule out supply issues. Inspect the internal fuse if accessible.
Ensure the 24 V DC supply is within tolerance. Replace the power supply if voltage is absent or out of range. If supply is correct, the internal display or power board may require replacement.
Panel shows 'No connection to PLC' message at startup
Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment.
Correct any wiring faults and ensure proper bus termination. Confirm that the station address and baud rate configured in the WinCC flexible project match the PLC settings exactly.
Project cannot be transferred to the panel
Check the communication interface selected in WinCC flexible matches the physical connection used. Verify the panel is in transfer mode (accessible via the panel's start center or loader menu).
Set the panel to transfer mode before initiating the download. Ensure the correct COM port or MPI adapter is selected in WinCC flexible. Try a different cable or MPI adapter if the issue persists.
Operator inputs via keys are not responding
Check whether the panel is in a locked or protected operating mode. Verify the project configuration for key assignments in WinCC flexible.
Disable any active screen protection or operator authorization lock. Re-download the project if key assignments appear incorrect. If hardware keys are physically unresponsive, the keypad membrane may require replacement.
Alarms are not displayed on the panel
Check the alarm configuration in the WinCC flexible project. Verify that the PLC bit or tag triggering the alarm is correctly addressed and that the alarm class is enabled for display.
Correct any tag addressing errors in the WinCC flexible project and re-transfer the project to the panel. Ensure the alarm view object is present and visible on the relevant screen.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page