• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7CA4 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7CA4 OP 77A

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7CA4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7CA4 is an operator panel belonging to the OP 77A series, part of the SIMATIC HMI family of human-machine interface devices. This compact panel is designed for machine-level operator control and monitoring tasks, providing a straightforward interface for process visualization and parameter input. It is a key component in Siemens' range of basic HMI panels, intended for integration into control cabinets and machine fronts.

    The OP 77A features a monochrome STN LCD display and a membrane keypad for operator input, supporting function keys and numeric/alphanumeric entry. It communicates via MPI and PROFIBUS DP interfaces, enabling direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel is configured using WinCC flexible software and supports recipe management, alarm logging, and trend display functions within its onboard memory capacity.

    The OP 77A is widely used in manufacturing, packaging, and process automation environments where a cost-effective, reliable operator interface is required at the machine level. Its compact form factor and robust membrane keypad make it suitable for installation in harsh industrial environments where space is limited. Industries such as food and beverage, automotive assembly, and general machine building commonly deploy this panel for local operator interaction with SIMATIC-based control systems.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Size 4 inches
    Display Colors Monochrome (blue/white)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 5 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Configuration Software WinCC flexible 2008
    Series/Product Family SIMATIC HMI OP 77A
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication interrupted on MPI/PROFIBUS DP interface.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and in RUN mode. Check bus address settings on both panel and PLC.
    Event ID: 10001
    No connection to configured PLC at startup; panel cannot establish initial communication.
    Verify the PLC address configured in WinCC flexible matches the physical PLC address. Check cable integrity and bus termination.
    Event ID: 20000
    Configuration data on the panel is invalid or corrupted.
    Re-transfer the project from WinCC flexible to the panel. Ensure the correct project version is used for this panel type.
    Event ID: 40000
    Operator panel internal memory error detected.
    Perform a factory reset of the panel and re-download the project. If the error persists, the panel may require hardware service or replacement.
    Event ID: 50000
    Tag value read from PLC is outside the configured limit range.
    Check the PLC program for correct tag value output. Verify limit values configured in the WinCC flexible project are appropriate for the process.
    Event ID: 60000
    Recipe data transfer error between panel and PLC.
    Check recipe configuration in WinCC flexible. Ensure PLC data blocks referenced by recipes exist and have the correct structure.
    Event ID: 70000
    Alarm buffer overflow; too many alarms generated in a short period.
    Review the alarm configuration in the project. Investigate the root cause of the high alarm rate in the PLC program and process.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A (6AV6355-1AA47-7CA4)?

    The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-200 via PPI protocol.

    What software is used to configure the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2008 or later. Projects are transferred to the panel via MPI cable or a direct serial/USB-to-MPI adapter.

    What is the supply voltage for the 6AV6355-1AA47-7CA4?

    The panel operates on 24 V DC supply voltage, which is the standard control voltage used in SIMATIC automation systems.

    What is the front panel protection rating of the OP 77A?

    The OP 77A provides IP65 protection at the front panel when correctly installed in a panel cutout with the supplied seal, making it suitable for environments with dust and water spray.

    Can the OP 77A display alarms and messages from the PLC?

    Yes, the OP 77A supports alarm and message display, including bit-triggered and word-triggered alarms configured in WinCC flexible, with an onboard alarm buffer for logging events.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals. Measure voltage at the panel connector to confirm supply integrity. Inspect for any blown internal fuse.

    Ensure the 24 V DC supply is within tolerance and correctly wired to the panel terminals. If supply is confirmed good and display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair.

    Panel shows 'No connection to PLC' message continuously

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated. Check that the PLC address in the WinCC flexible project matches the actual PLC hardware address. Confirm the PLC is powered and in RUN or STOP mode.

    Correct any address mismatches in the project configuration and re-download. Replace the communication cable if damaged. Ensure bus termination resistors are enabled only at the physical ends of the bus.

    Touchscreen or keypad inputs not responding

    The OP 77A uses a membrane keypad rather than a touchscreen. Check if the keypad membrane is physically damaged or contaminated. Verify the panel is not in a locked or password-protected state.

    Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly requires replacement. Unlock the panel via the configured unlock sequence if operator access is restricted.

    Project transfer from WinCC flexible fails

    Check the MPI cable connection between the PC and the panel. Verify the correct COM port and transfer speed are selected in WinCC flexible. Confirm the panel is in transfer mode.

    Place the panel in transfer mode by navigating to the transfer menu on the panel. Use a known-good MPI/PC adapter cable. Ensure WinCC flexible is set to the correct baud rate matching the panel's MPI settings (typically 187.5 kbps).

    Alarm messages displayed in incorrect language

    The display language is configured within the WinCC flexible project. If the wrong language is shown, the project may have been downloaded with an incorrect language setting or the runtime language selection is misconfigured.

    Open the WinCC flexible project, verify the configured languages and the default runtime language. Re-download the corrected project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart