• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7CA1 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7CA1 OP 77A

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7CA1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7CA1 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for machine-level operator control and monitoring tasks. This unit provides a straightforward interface for process visualization and parameter input in automation environments.

    The OP 77A features a monochrome STN LCD display with a resolution of 128 x 64 pixels, capable of displaying text and simple graphics. It is equipped with a membrane keypad for operator input, including function keys and system keys. Communication is handled via MPI and PROFIBUS DP interfaces, enabling direct integration with Siemens SIMATIC S7 PLCs. The panel supports configuration via Siemens WinCC flexible software and offers a compact, panel-mount design suitable for control cabinet door installation.

    The OP 77A is widely used in manufacturing, machine building, and process automation where a cost-effective, reliable operator interface is required. It is particularly suited for applications involving SIMATIC S7-200, S7-300, and S7-400 PLC systems. Typical installations include packaging machinery, conveyor systems, and general industrial machine control panels.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 128 x 64 pixels
    Display Size 3.2 inch
    Input Voltage 24 V DC
    Power Consumption 4 W (typical)
    Communication Interface MPI / PROFIBUS DP
    Configuration Software WinCC flexible 2005 or higher
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL
    Series SIMATIC HMI OP 77A

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC interrupted or PLC not reachable
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and in RUN mode. Check configured station address matches PLC settings.
    Event ID: 10001
    Communication timeout with configured controller
    Verify communication parameters (baud rate, station address) in WinCC flexible project match PLC configuration. Check cable integrity and bus termination.
    Event ID: 20000
    Project download failed or project data corrupted
    Re-download the WinCC flexible project to the panel. Ensure the correct panel type is selected in the project settings and that the transfer cable is functioning correctly.
    Event ID: 40000
    Operating system error or firmware fault detected
    Perform a panel reset. If the fault persists, update the panel firmware using ProSave or WinCC flexible and re-download the project.
    Event ID: 50000
    Tag value out of configured limit range
    Check the process value limits configured in WinCC flexible for the affected tag. Verify the PLC program is writing values within the expected range.
    Event ID: 70000
    No project loaded on the panel
    Download a valid WinCC flexible project to the panel using the configured transfer interface (MPI or PROFIBUS DP). Ensure transfer mode is enabled on the panel.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A?

    The OP 77A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.

    What software is used to configure the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2005 or later versions. Projects are downloaded to the panel via the MPI or PROFIBUS DP interface.

    What is the supply voltage for the 6AV6355-1AA47-7CA1?

    The panel operates on a 24 V DC supply voltage, which is the standard supply for SIMATIC HMI operator panels.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Can the OP 77A display graphics or only text?

    The OP 77A can display both text and simple bitmap graphics on its 128 x 64 pixel monochrome LCD, though it is primarily optimized for text-based operator interaction.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuse or wiring fault.

    Ensure the 24 V DC supply is stable and within tolerance. Replace the supply fuse if blown. If the display remains blank with correct supply voltage, the internal power supply or display unit may require replacement.

    Panel shows 'No project' or 'Transfer' screen on startup

    The panel has no valid project loaded, or it has been reset to transfer mode. This is a configuration state, not a hardware fault.

    Download a valid WinCC flexible project to the panel using the MPI or PROFIBUS DP interface. Ensure the correct panel type is selected in the project before downloading.

    Communication error displayed — PLC not reachable

    Check the MPI or PROFIBUS DP cable connection between the panel and the PLC. Verify bus termination at both ends of the network segment.

    Replace or reseat the communication cable. Confirm that the station address and baud rate configured in the WinCC flexible project match the PLC settings. Ensure the PLC is powered and in RUN mode.

    Function keys not responding to operator input

    Inspect the membrane keypad for physical damage or contamination. Test each key systematically using the panel's built-in key test function if available in the service menu.

    Clean the keypad surface. If individual keys are unresponsive due to membrane damage, the keypad assembly will need to be replaced. Contact a qualified repair technician for membrane replacement.

    Panel repeatedly restarts or enters bootloader mode

    This may indicate corrupted firmware or a failed project download. Check if the panel enters a continuous reboot loop or displays a firmware error message.

    Use Siemens ProSave tool to restore the panel firmware via the MPI interface. After firmware restoration, re-download the WinCC flexible project. If the issue persists, the panel may require hardware-level repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart