Siemens 6AV6355-1AA47-7BB1 OP 77B
The Siemens 6AV6355-1AA47-7BB1 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. This unit provides a compact, keypad-based human-machine interface designed for straightforward machine-level operation and monitoring tasks. It is part of Siemens' established line of operator panels engineered for reliable performance in industrial environments.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a backlit screen for clear readability. It supports communication via MPI, PROFIBUS DP, and RS 422/485 interfaces, enabling integration with SIMATIC S7 PLCs and other compatible controllers. The panel includes function keys and system keys for navigation, and is configured using WinCC flexible software. It operates on a 24 V DC supply and carries an IP65 protection rating on the front panel, making it suitable for panel-mount installations in demanding environments.
The OP 77B is widely used in manufacturing, machine building, and process automation applications where a cost-effective, robust operator interface is required. It is particularly suited for controlling and monitoring individual machines or production cells in industries such as automotive, food and beverage, packaging, and general factory automation. Its compact form factor and straightforward keypad operation make it appropriate for applications where touchscreen functionality is not required.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Size | 4 inch |
| Input Voltage | 24 V DC |
| IP Rating (Front) | IP65 |
| Communication Interface | MPI, PROFIBUS DP, RS 422/485 |
| Configuration Software | WinCC flexible 2008 or later |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mount |
| Series/Product Family | SIMATIC HMI OP 77B |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC or controller.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the configured station address matches the PLC settings. Restart both the panel and the PLC. - Event ID: 10001
- Connection to the PLC has been interrupted or timed out.
Verify the communication cable integrity and connector seating. Check that the PLC is powered and in RUN mode. Confirm baud rate and address settings in the project configuration. - Event ID: 20000
- Project download error or configuration data mismatch detected on the panel.
Re-download the project from WinCC flexible to the panel. Ensure the WinCC flexible version is compatible with the panel firmware version. - Event ID: 40000
- Tag read/write error — the panel cannot access a configured PLC data address.
Verify the PLC data block and address referenced in the WinCC flexible project exist and are accessible. Check PLC program for correct data block definitions. - Event ID: 50000
- System memory low or project memory limit reached on the panel.
Reduce the number of screens, tags, or graphic objects in the project. Optimize the project in WinCC flexible and re-download to the panel. - Event ID: 60000
- Firmware update error or incompatible firmware version detected.
Use the correct firmware version compatible with the 6AV6355-1AA47-7BB1 hardware revision. Re-flash the firmware using ProSave or WinCC flexible. - Event ID: 70000
- Internal panel hardware fault or watchdog timeout occurred.
Power cycle the panel. If the fault persists, perform a factory reset using the panel's loader menu. If unresolved, the unit may require repair or replacement.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B (6AV6355-1AA47-7BB1)?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with S7-200 via RS 422/485 using the PPI protocol.
What software is used to configure and program the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via a PC adapter or MPI/USB cable.
What is the supply voltage for the 6AV6355-1AA47-7BB1?
The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid operational faults.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.
Can the OP 77B display graphics and images?
The OP 77B has a monochrome display with limited graphical capability. It supports basic bitmap graphics and bar graphs, but is primarily designed for text-based operation and simple process visualization.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel's power connector. Verify the supply is within the acceptable voltage range and that the connector is firmly seated.
Restore correct 24 V DC supply. If the supply is confirmed correct and the display remains blank, the internal power supply or backlight may be faulty and the unit should be inspected for repair.
Panel shows 'No connection to PLC' or communication error on startup
Inspect the MPI or PROFIBUS DP cable for damage and verify connector termination. Check that the station address configured in the project matches the physical PLC address setting.
Replace or reseat the communication cable. Correct the station address in the WinCC flexible project and re-download. Ensure termination resistors are correctly placed at both ends of the bus.
Project download fails from WinCC flexible
Verify the PC-to-panel connection cable (PC adapter or MPI/USB adapter) is functioning correctly. Check that the WinCC flexible project is compiled without errors before attempting download.
Try a different PC adapter or cable. Ensure the panel is in transfer mode (accessible via the loader menu). Confirm the WinCC flexible version is compatible with the panel firmware.
Panel freezes or becomes unresponsive during operation
Check for memory overload in the project configuration. Verify that the PLC communication is stable and not generating excessive error events that could overload the panel processor.
Power cycle the panel to restore operation. Optimize the WinCC flexible project by reducing the number of active tags and screen objects. Update the panel firmware to the latest compatible version if the issue recurs.
Function keys do not respond or produce incorrect actions
Check the key assignment configuration in the WinCC flexible project. Inspect the keypad membrane for physical damage or contamination that may cause key contact issues.
Verify and correct key assignments in the project configuration and re-download. If physical key damage is confirmed, the keypad membrane or the complete panel front may require replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page