• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6344-2AD24-0CG6 OP 177B
    Awaiting product image

    Siemens 6AV6344-2AD24-0CG6 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6344-2AD24-0CG6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6344-2AD24-0CG6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with keypad-based operation, serving as a compact and robust panel for process visualization and control. As part of Siemens' established SIMATIC HMI portfolio, it is engineered for reliable integration into automated production environments.

    The OP 177B features a 5.7-inch STN display and supports both MPI and PROFIBUS DP communication interfaces, enabling seamless connectivity with SIMATIC S7 PLCs and other compatible controllers. It includes integrated Ethernet capability and supports configuration via WinCC flexible engineering software. The panel offers a membrane keypad with function keys, providing tactile feedback for operator input, and is built to withstand industrial environments with an IP65 front panel protection rating.

    The OP 177B is widely deployed in manufacturing, automotive, food and beverage, and process industries where a compact, keypad-operated HMI is required at the machine level. Its compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a common choice for retrofitting and new installations alike. The panel's robust construction and broad communication support make it suitable for applications requiring reliable local operator control and status visualization.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Display Resolution 320 x 240 pixels (QVGA)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (RJ45)
    IP Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible 2005 or higher
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected on startup; the loaded project is incompatible with the panel firmware version.
    Re-transfer a compatible project using WinCC flexible. Ensure the firmware version on the panel matches the project settings.
    Event ID: 20000
    Communication connection to the PLC has been lost or cannot be established.
    Check MPI/PROFIBUS DP or Ethernet cabling and termination resistors. Verify PLC address settings match the HMI project configuration.
    Event ID: 40000
    Tag read/write error; the HMI cannot access a configured PLC tag.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check PLC program for address conflicts.
    Event ID: 50000
    Internal device error or hardware fault detected.
    Perform a power cycle. If the fault persists, back up the project and perform a factory reset, then re-transfer the project. Contact Siemens support if unresolved.
    Event ID: 60000
    Overflow of the alarm or event buffer; too many simultaneous alarms are pending.
    Acknowledge and clear active alarms. Review the alarm configuration in WinCC flexible to reduce simultaneous alarm load or increase buffer size.
    Event ID: 70000
    Recipe data error; a recipe record could not be read from or written to memory.
    Check available internal memory on the panel. Verify recipe configuration in WinCC flexible and re-transfer the project if necessary.
    Event ID: 80000
    Firmware update failed or interrupted during the update process.
    Restart the firmware update procedure using ProSave or WinCC flexible. Ensure stable power supply during the update and use the correct firmware version for this panel.

    Frequently Asked Questions

    Which communication interfaces does the OP 177B (6AV6344-2AD24-0CG6) support?

    The OP 177B supports MPI, PROFIBUS DP, and Ethernet (RJ45) interfaces, allowing direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs as well as third-party controllers via appropriate drivers.

    Which engineering software is required to configure this panel?

    The OP 177B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via Ethernet, MPI, or USB connection.

    What is the supply voltage for the 6AV6344-2AD24-0CG6?

    The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI devices in this class.

    Is the OP 177B compatible with TIA Portal?

    The OP 177B is not natively supported in TIA Portal; it is configured exclusively with WinCC flexible. Migration to a newer panel such as the KTP700 Basic would be required for TIA Portal-based projects.

    What is the front panel protection rating of this unit?

    The OP 177B has an IP65 protection rating on the front panel, making it resistant to dust and water jets, suitable for most industrial machine enclosures.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the supply is within the specified range and that the connector is properly seated.

    Restore correct 24 V DC supply. If voltage is correct and display remains blank, the internal backlight or power supply board may be faulty and the unit should be sent for repair or replacement.

    Panel fails to communicate with the PLC via PROFIBUS DP

    Verify PROFIBUS cable connections, bus termination at both ends of the network, and that the panel's PROFIBUS address in WinCC flexible matches the configured address on the panel itself.

    Correct any address mismatches via the panel's Start Center settings. Replace damaged PROFIBUS cables or connectors. Ensure bus termination resistors are active only at the two physical ends of the network.

    Touchscreen or keypad inputs are not responding correctly

    Check for physical damage to the membrane keypad. Perform a keypad test via the panel's Start Center diagnostics menu to identify unresponsive keys.

    Clean the keypad surface. If keys are mechanically damaged or the membrane is worn, the keypad assembly requires replacement. For persistent issues, a firmware re-flash may resolve software-related input faults.

    Project transfer fails from WinCC flexible to the panel

    Confirm the transfer channel settings in WinCC flexible match the physical connection type (Ethernet, MPI, or USB). Check that the panel is in Transfer mode via the Start Center.

    Switch the panel to Transfer mode manually through the Start Center. Verify IP address or MPI address settings. Try an alternative transfer cable or interface. Ensure WinCC flexible version is compatible with the panel firmware.

    Panel repeatedly restarts or shows a boot loop

    A corrupted project or failed firmware update can cause continuous restarts. Attempt to access the Start Center by pressing the appropriate key combination during boot.

    Enter the Start Center and perform a factory reset (Format Memory). Re-transfer a valid project using WinCC flexible. If the boot loop persists, the panel firmware may need to be reloaded using ProSave via the service interface.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart