Siemens 6AV6344-2AC34-0MG6 OP177B
The Siemens 6AV6344-2AC34-0MG6 is an OP177B operator panel belonging to the SIMATIC HMI family, designed for machine-level human-machine interface applications. This unit provides a monochrome graphical display with keypad-based operation, enabling operators to monitor and control industrial processes without requiring a touchscreen interface. As part of the SIMATIC HMI Basic Panels generation, it is engineered for reliable integration with Siemens SIMATIC S7 and other compatible PLC platforms.
The OP177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and is operated via a membrane keypad with function keys, system keys, and alphanumeric input capability. It supports communication via MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, allowing flexible connection to a wide range of controllers. The panel is configured using WinCC flexible software and offers internal flash memory for project storage, along with a USB interface and memory card slot for data transfer and project backup. The unit operates on 24 V DC supply and carries CE and UL certifications.
The OP177B is widely deployed in machine building, packaging machinery, material handling systems, and process automation where a robust, keypad-operated HMI is preferred over touchscreen solutions. Its compatibility with PROFIBUS DP makes it suitable for distributed automation architectures, and its compact panel-mount form factor allows integration into standard control cabinets and machine enclosures. Industries such as automotive manufacturing, food and beverage processing, and general factory automation commonly utilize this panel for local operator interaction.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome |
| Display Resolution | 320 x 240 pixels |
| Display Colors | Monochrome (blue-mode) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | MPI, PROFIBUS DP, RS-422/RS-485 |
| Configuration Software | WinCC flexible 2008 or higher |
| Memory | Internal flash memory, memory card slot (MMC) |
| USB Interface | USB Type A (for data transfer) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes and System Events
- Event ID: 10000
- Configuration error detected during startup; the loaded project is incompatible or corrupted.
Reload the project using WinCC flexible. Verify the project was compiled for the correct HMI device type and firmware version. - Event ID: 20000
- Communication error on MPI or PROFIBUS DP interface; connection to the PLC has been lost.
Check physical wiring and bus termination resistors. Verify MPI/PROFIBUS address settings on both the HMI and the PLC. Ensure the PLC is in RUN mode. - Event ID: 40000
- Tag read/write error; the HMI cannot access a configured PLC tag.
Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory area. Check PLC program for correct data types. - Event ID: 50000
- Recipe data error; a recipe record cannot be read from or written to the configured storage location.
Check available memory on the MMC or internal flash. Verify recipe configuration in WinCC flexible and ensure the storage medium is correctly inserted. - Event ID: 60000
- System memory low warning; available internal memory for runtime operation is critically low.
Reduce the number of active alarms, logged data, or recipe records. Archive and clear historical data from the memory card. - Event ID: 70000
- Firmware update error; the firmware transfer to the device was interrupted or the firmware file is invalid.
Restart the firmware update procedure using ProSave or WinCC flexible. Ensure the correct firmware version for the 6AV6344-2AC34-0MG6 is used and the power supply is stable during transfer. - Event ID: 80000
- Alarm buffer overflow; the number of pending alarms exceeds the buffer capacity.
Acknowledge and clear active alarms. Review the alarm configuration in WinCC flexible to reduce simultaneous alarm triggers or increase the alarm buffer size if possible.
Frequently Asked Questions
What communication interfaces does the OP177B (6AV6344-2AC34-0MG6) support?
The OP177B supports MPI, PROFIBUS DP, and RS-422/RS-485 serial interfaces, enabling connection to Siemens S7-200, S7-300, and S7-400 PLCs as well as third-party controllers via serial protocols.
Which software is used to configure and program this HMI panel?
The 6AV6344-2AC34-0MG6 is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are compiled and transferred to the panel via MPI, PROFIBUS, or USB connection.
What is the supply voltage for the OP177B?
The panel operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to avoid damage or operational faults.
Is the OP177B compatible with S7-1200 or S7-1500 PLCs?
The OP177B is primarily designed for use with S7-200, S7-300, and S7-400 PLCs using WinCC flexible. For S7-1200 and S7-1500 integration, Siemens recommends using newer HMI panels configured with TIA Portal.
What is the front panel protection rating of the 6AV6344-2AC34-0MG6?
The front panel of the OP177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector. Check for correct polarity. Inspect the internal fuse if accessible.
Correct any wiring errors or supply voltage issues. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight may require replacement.
HMI cannot establish communication with the PLC
Check the MPI or PROFIBUS cable connections and verify bus termination at both ends of the network. Confirm the HMI station address does not conflict with other devices on the bus.
Replace or reseat the communication cable. Set the correct MPI or PROFIBUS address in the HMI Control Panel settings. Ensure the PLC is powered and in RUN or STOP mode with communications active.
Project fails to transfer from WinCC flexible to the panel
Verify the USB or MPI connection between the engineering PC and the HMI. Check that the WinCC flexible project is compiled without errors and targets the correct device type.
Recompile the project in WinCC flexible and retry the transfer. If using USB, try a different cable or port. Alternatively, transfer the project via a MultiMediaCard (MMC) inserted into the panel's memory card slot.
Keypad buttons are unresponsive or register incorrect inputs
Inspect the membrane keypad for physical damage, contamination, or deformation. Check if the issue is limited to specific keys or affects all keys.
Clean the keypad surface with a dry cloth. If individual keys are permanently unresponsive, the membrane keypad assembly requires replacement. Contact a qualified repair technician to replace the keypad module.
Panel repeatedly restarts or enters a boot loop
Check the 24 V DC supply for voltage fluctuations or drops under load. Verify the project stored in flash memory is not corrupted by attempting to reload it via ProSave in bootstrap mode.
Stabilize the power supply and ensure adequate current capacity. Use ProSave to perform a factory reset and reload a freshly compiled project. If the issue persists, the internal flash memory or main board may be faulty and require service.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page