Siemens 6AV6343-3AA14-0MA6 OP 177B
€ 1.995,00
The Siemens 6AV6343-3AA14-0MA6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome STN display with touch and key-based operation, enabling operators to monitor and control industrial processes directly at the machine. It is part of Siemens' established SIMATIC HMI portfolio, offering a compact and robust panel solution for demanding industrial environments.
The OP 177B features a 5.7-inch STN display with a resolution of 320 x 240 pixels and supports both touch screen and membrane keypad input for flexible operator interaction. It is equipped with MPI, PROFIBUS DP, and Ethernet (TCP/IP) communication interfaces, allowing integration with SIMATIC S7 PLCs and other compatible controllers. The panel includes 512 KB of user memory for project data, supports recipe management, alarm logging, and trend displays, and operates on a 24 V DC supply. The unit is rated IP65 at the front panel, providing protection against dust and water ingress in harsh industrial settings.
The OP 177B is widely deployed in manufacturing, automotive, food and beverage, and process industries where reliable local operator control is required. It is particularly suited for machine-level HMI tasks on conveyor systems, packaging machinery, and production lines where a compact panel with both touch and key input is advantageous. Its compatibility with the SIMATIC S7-200, S7-300, and S7-400 controller families makes it a versatile choice for a broad range of automation architectures.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Input Method | Touch screen and membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | MPI, PROFIBUS DP, Ethernet TCP/IP (RJ45) |
| User Memory | 512 KB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC or controller.
Check MPI/PROFIBUS or Ethernet cable connections. Verify PLC address settings and communication parameters in the project configuration. Ensure the PLC is in RUN mode. - Event ID: 10001
- Connection to the configured PLC has been interrupted or lost during operation.
Inspect communication cables for damage. Verify network settings and PLC availability. Restart the HMI panel and PLC if the connection is not re-established automatically. - Event ID: 20000
- Project download error — the project could not be transferred to the HMI panel successfully.
Check the transfer cable or network connection between the engineering PC and the panel. Ensure WinCC flexible is configured with the correct transfer settings and that the panel is in transfer mode. - Event ID: 40000
- System memory low — available memory on the HMI device is insufficient for the current project.
Reduce the project size by optimizing graphics, alarm lists, or recipe data. Delete unused project elements and re-download the project to the panel. - Event ID: 50000
- Configuration error detected — a mismatch exists between the project configuration and the connected hardware or PLC type.
Verify that the HMI project is configured for the correct PLC type and firmware version. Re-download the project after correcting the configuration in WinCC flexible. - Event ID: 60000
- Operating system or firmware error on the HMI panel.
Perform a panel reset by holding the appropriate key combination during startup. If the fault persists, reload the panel firmware using ProSave or WinCC flexible. - Event ID: 70000
- Tag or variable update error — one or more configured tags cannot be read from or written to the PLC.
Check that the PLC data addresses referenced in the project are valid and accessible. Verify that the PLC program contains the expected data blocks or memory areas.
Frequently Asked Questions
Which PLCs are compatible with the OP 177B (6AV6343-3AA14-0MA6)?
The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP, as well as with S7-300/400 via Ethernet TCP/IP. It also supports communication with a range of third-party controllers through configurable drivers in WinCC flexible.
What software is used to configure and program the OP 177B?
The OP 177B is configured using Siemens WinCC flexible 2008 or later. Projects are created on an engineering PC and transferred to the panel via MPI, PROFIBUS, or Ethernet connection.
What is the input voltage requirement for this panel?
The OP 177B requires a 24 V DC power supply with a maximum power consumption of approximately 9 W.
Is the OP 177B front panel protected against dust and water?
Yes, the front panel of the OP 177B is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets. The rear of the unit is rated IP20.
Can the OP 177B be used as a replacement for older Siemens OP panels?
The OP 177B is designed as a successor to earlier SIMATIC HMI operator panels such as the OP 17 and OP 170B, and can often serve as a functional replacement with appropriate project migration in WinCC flexible.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply terminals. Measure voltage at the panel connector and inspect the supply cable for damage or loose connections.
Restore correct 24 V DC supply. If voltage is present but the display remains blank, the internal power supply board or backlight may be faulty and require replacement.
Panel does not communicate with the PLC via PROFIBUS or MPI
Verify the PROFIBUS/MPI cable is correctly connected and terminated. Check the bus address configured on the panel matches the project settings. Use a PROFIBUS diagnostic tool to check bus integrity.
Correct any address conflicts, replace damaged cables, and ensure proper bus termination resistors are in place at both ends of the network. Re-download the project if communication parameters were changed.
Touch screen does not respond or responds inaccurately
Check for physical damage or contamination on the touch surface. Attempt to recalibrate the touch screen through the panel's Start Center or Control Panel menu.
Clean the touch surface with a soft, dry cloth. Perform a touch screen calibration via the panel settings. If calibration fails or the screen remains unresponsive, the touch foil or controller board may need replacement.
Project transfer from WinCC flexible fails
Confirm the panel is set to transfer mode. Check the communication cable or Ethernet connection between the engineering PC and the panel. Verify that the correct interface and transfer settings are selected in WinCC flexible.
Set the panel to transfer mode via the Start Center. Use a known-good cable and ensure firewall or antivirus software on the PC is not blocking the transfer. Retry the download after correcting the settings.
Alarm messages are not displayed or are missing
Check that alarm tags are correctly configured in the WinCC flexible project and that the corresponding PLC data addresses are valid. Verify that the alarm view object is present and correctly configured on the relevant screen.
Correct any misconfigured alarm tags or address references in the project and re-download to the panel. Ensure the PLC program is writing the expected values to the alarm trigger bits.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page