• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6343-3AA14-0CB6 OP 177B
    Awaiting product image

    Siemens 6AV6343-3AA14-0CB6 OP 177B

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6343-3AA14-0CB6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6343-3AA14-0CB6 is an OP 177B operator panel belonging to the SIMATIC HMI family, designed for machine-level visualization and operator control in industrial automation environments. This unit provides a compact, robust interface for process monitoring and control, and is part of Siemens' mid-range HMI portfolio configured for use with SIMATIC PLCs and third-party controllers. The OP 177B is engineered for panel mounting and offers a monochrome or color display depending on the specific variant, with this part number indicating a color STN display configuration.

    The 6AV6343-3AA14-0CB6 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA) and supports touch and key-based operation through integrated function keys. It is equipped with MPI/PROFIBUS DP and RS-422/RS-485 interfaces for communication with SIMATIC S7 PLCs and other controllers, and includes a USB port for project transfer and data backup. The panel runs on WinCC flexible runtime software, supports recipe management, alarm logging, and trend displays, and provides 512 KB of user memory for project data.

    The OP 177B is widely deployed in machine building, packaging, food and beverage processing, and general manufacturing applications where a reliable, mid-range HMI is required. Its compatibility with the SIMATIC S7-200, S7-300, and S7-400 PLC families makes it a versatile choice for both new installations and system upgrades. The panel's robust construction and wide operating temperature range make it suitable for demanding industrial environments.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN color
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors 256 colors
    Touch Technology Resistive touch screen with function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI/PROFIBUS DP, RS-422/RS-485, USB
    User Memory 512 KB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error: The project loaded on the panel is incompatible with the connected PLC or contains configuration faults.
    Check the WinCC flexible project configuration, verify PLC type and address settings, and reload a compatible project via USB or MPI.
    Event ID: 10001
    Communication error: The HMI panel cannot establish or maintain a connection to the configured PLC.
    Check MPI/PROFIBUS DP cable connections and termination resistors, verify the PLC address and baud rate settings match the HMI project configuration.
    Event ID: 20000
    Tag read error: A configured tag cannot be read from the PLC, typically due to an incorrect address or PLC program mismatch.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory area. Correct and reload the project.
    Event ID: 20001
    Tag write error: The HMI panel is unable to write a value to the configured PLC tag.
    Check PLC write permissions, verify the tag address and data type in the project configuration, and ensure the PLC is in RUN mode.
    Event ID: 40000
    Recipe data error: A recipe record cannot be read or written correctly, possibly due to a data inconsistency or memory issue.
    Check recipe configuration in WinCC flexible, verify available memory on the panel, and re-transfer the project if necessary.
    Event ID: 50000
    System memory low: Available runtime memory on the HMI panel is critically low, which may cause instability or loss of data.
    Reduce the complexity of the loaded project, minimize the number of active alarms and trends, or archive data to free up memory.
    Event ID: 60000
    Operating system error: An internal software fault has been detected, which may cause the panel to restart or freeze.
    Perform a controlled restart of the panel. If the fault persists, reload the firmware using the Siemens ProSave tool and re-transfer the project.
    Event ID: 70000
    Hardware fault: An internal hardware component has reported an error, such as a display or touch controller fault.
    Inspect the panel for physical damage. If the display or touch function is affected, the unit may require professional repair or replacement of the affected module.

    Frequently Asked Questions

    What PLC families are compatible with the OP 177B (6AV6343-3AA14-0CB6)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports communication with third-party controllers via the RS-422/RS-485 interface using appropriate drivers in WinCC flexible.

    What software is used to configure and program the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible software. Projects are transferred to the panel via USB or MPI connection using WinCC flexible or the ProSave utility.

    What is the supply voltage for the 6AV6343-3AA14-0CB6?

    The panel operates on 24 V DC. Ensure the power supply is within the specified tolerance range to avoid damage or instability.

    What is the IP protection rating of the OP 177B front panel?

    The front panel of the OP 177B is rated IP65, providing protection against dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Can the OP 177B firmware be updated in the field?

    Yes, the firmware can be updated using the Siemens ProSave tool, which transfers the firmware image to the panel via USB or MPI/PROFIBUS DP connection.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel power connector. Check for blown internal fuses and verify the power supply is within tolerance.

    Restore correct 24 V DC supply voltage. If the supply is correct and the display remains blank, the backlight or internal power board may require replacement by a qualified repair technician.

    HMI panel fails to communicate with the PLC

    Check the MPI or PROFIBUS DP cable for continuity and correct termination at both ends. Verify that the PLC address and baud rate configured in the WinCC flexible project match the actual PLC settings.

    Replace or reseat the communication cable, correct the address and baud rate settings in the project, and reload the project to the panel. Ensure bus termination resistors are correctly placed at both ends of the network.

    Touch screen does not respond or responds inaccurately

    Inspect the touch screen surface for damage, contamination, or excessive pressure marks. Attempt a touch screen recalibration from the panel's Start Center menu.

    Clean the touch screen surface with a soft, dry cloth. Recalibrate the touch screen via the Start Center. If the problem persists, the touch screen overlay may need to be replaced.

    Project transfer via USB fails or is not recognized

    Check that the USB memory stick is formatted as FAT32 and that the project file was exported correctly from WinCC flexible. Verify the USB port on the panel is not physically damaged.

    Reformat the USB stick as FAT32, re-export the project from WinCC flexible, and retry the transfer. Alternatively, use the MPI connection with ProSave for project transfer if the USB port is faulty.

    Panel repeatedly restarts or displays a runtime error

    Check the loaded project for configuration errors using WinCC flexible. Verify that the firmware version on the panel is compatible with the WinCC flexible project version.

    Reload a validated project to the panel. If the issue persists, update the panel firmware to the correct version using ProSave, then re-transfer the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart