
Siemens 6AV6343-3AA04-0MA6 OP 177B
€ 1.995,00
The Siemens 6AV6343-3AA04-0MA6 is the OP 177B operator panel, part of the SIMATIC HMI family of human-machine interface devices. This unit provides a monochrome STN display with touch and key-based operation, designed for machine-level visualization and control tasks. It belongs to the Comfort and Advanced panel generation predecessor line, offering reliable panel communication with Siemens SIMATIC PLCs and third-party controllers.
The OP 177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and supports both MPI/PROFIBUS DP and Ethernet (PROFINET) communication interfaces, enabling flexible integration into existing automation networks. The panel is configured using WinCC flexible 2008 engineering software and supports recipe management, alarm logging, and trend display functions. It includes 2 MB user memory for project data and operates on a 24 V DC supply. The unit also provides USB and RS-422/RS-485 serial interfaces for peripheral connectivity.
The OP 177B is widely used in manufacturing, packaging, and process automation applications where a compact, robust operator interface is required at the machine level. Its compatibility with SIMATIC S7-200, S7-300, and S7-400 PLCs makes it suitable for a broad range of industrial control systems. The panel's IP65 front protection rating allows installation in control cabinet doors in environments with dust and water spray exposure.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Touch Technology | Resistive touch screen with membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | MPI/PROFIBUS DP, PROFINET (Ethernet), RS-422/RS-485, USB |
| User Memory | 2 MB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Engineering Software | WinCC flexible 2008 |
Common Error Codes and System Events
- Event ID: 10000
- System startup completed successfully. The HMI panel has booted and the runtime is active.
No action required. This is an informational event confirming normal startup. - Event ID: 10001
- Power failure detected. The panel lost power unexpectedly during operation.
Check the 24 V DC supply voltage and wiring at the power connector. Ensure the power supply unit is stable and within specification. - Event ID: 20000
- Communication error on MPI/PROFIBUS DP interface. The panel cannot establish or maintain a connection to the configured PLC.
Verify MPI/PROFIBUS address settings, cable connections, and termination resistors. Check PLC is powered and in RUN mode. - Event ID: 20001
- Ethernet/PROFINET communication error. The panel cannot reach the configured PLC or network device via Ethernet.
Check Ethernet cable and switch connections. Verify IP address configuration on both the panel and PLC. Ensure no IP address conflicts exist. - Event ID: 40000
- Project download error. A project transfer from the engineering PC to the panel failed or was interrupted.
Restart the transfer process in WinCC flexible. Check USB or Ethernet connection between PC and panel. Ensure sufficient free memory on the panel. - Event ID: 50000
- Tag read/write error. The panel is unable to read from or write to a configured PLC tag.
Verify the tag address and data type configuration in WinCC flexible. Check PLC program to confirm the data block or memory area exists and is accessible. - Event ID: 60000
- Recipe data error. A recipe read or write operation could not be completed.
Check recipe configuration in WinCC flexible. Verify that the target PLC data block is correctly defined and that the panel has sufficient memory for recipe storage.
Frequently Asked Questions
What communication interfaces does the OP 177B (6AV6343-3AA04-0MA6) support?
The OP 177B supports MPI/PROFIBUS DP, PROFINET (Ethernet), RS-422/RS-485 serial, and USB interfaces, allowing connection to a wide range of Siemens and third-party PLCs.
Which engineering software is required to configure the OP 177B?
The OP 177B is configured using Siemens WinCC flexible 2008. Projects created in this software are transferred to the panel via USB or Ethernet.
Which Siemens PLCs are compatible with the OP 177B?
The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI/PROFIBUS DP, as well as S7-300/400 via PROFINET Ethernet communication.
What is the front panel protection rating of the OP 177B?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments with dust and water spray.
What is the operating supply voltage for the 6AV6343-3AA04-0MA6?
The panel operates on a 24 V DC supply voltage, which is the standard control cabinet supply voltage used in industrial automation systems.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel power connector. Check for blown internal fuse or faulty power supply unit.
Ensure the supply voltage is within the 24 V DC specification. Replace the power supply if voltage is absent at the connector. If voltage is present but display is blank, the panel may require repair or replacement of the display backlight.
Panel cannot communicate with PLC via MPI/PROFIBUS
Check the MPI/PROFIBUS cable connections and verify the bus termination resistors are correctly placed at both ends of the bus. Confirm the panel MPI address does not conflict with other devices.
Correct any wiring faults and ensure proper bus termination. Set a unique MPI/PROFIBUS address on the panel via the Start Center settings menu. Verify the PLC is powered and in RUN mode.
Project transfer from WinCC flexible fails
Check the USB or Ethernet connection between the engineering PC and the panel. Confirm the panel is in Transfer mode via the Start Center.
Restart the panel in Transfer mode by selecting Transfer in the Start Center. Re-initiate the download from WinCC flexible. If using Ethernet, verify the IP address settings match between the PC and panel.
Touch screen does not respond accurately or at all
Check for physical damage to the touch surface. Attempt to recalibrate the touch screen via the panel's Start Center or control panel settings.
Perform a touch screen calibration through the Start Center. If calibration does not resolve the issue, the touch screen overlay may be damaged and require replacement.
Panel repeatedly restarts or crashes during runtime
Check the project for configuration errors or unsupported functions. Monitor the 24 V DC supply for voltage drops or instability under load.
Reload the project from WinCC flexible after verifying the configuration. Ensure the power supply is rated for the panel's current draw. If the issue persists, perform a factory reset via the Start Center and re-download the project.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page



